Compact Cylinder/Guide Rod Type Series CQM Lateral load resisting 2 to 4 times ∗ Compared to compact cylinder Series CQ Non-rotating accuracy Refer to page 794 for details. External dimensions Slide bearing Load can be directly mounted. Mounting dimensions compatible with Series CQS, CQ2. Auto switch is mountable/removable even when the plate is retracted. Series Variations Series Rubber bumper Technical data
Open the catalog to page 1Compact Cylinder: Guide Rod Type CQM B 20 With auto switch Number of auto switches With auto switch (Built-in magnet) Through-hole (Standard) Both ends tapped (ø32 to ø100) Auto switch type Note 1) Cylinder bodies of ø12 to ø25 are common for both B (through hole) and A (both ends tapped) types. Symbol to order is unified to “B” for those sizes. Note 2) Cylinder mounting bolts are not included. Order them separately referring to Mounting Bolts for CQM on pages 796 and 797. Note 3) Contact SMC for the other mounting types. Without auto switch ∗ Refer to the table below for the applicable auto...
Open the catalog to page 2Compact Cylinder: Guide Rod Type Bore size (mm) Model Action Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Cushion Pneumatic (non-lube) type Double acting, Single rod Air 1.5 MPa 1.0 MPa 0.12 MPa 0.1 MPa Without auto switch: –10°C to 70°C (No freezing) With auto switch: –10°C to 60°C (No freezing) Rubber bumper on both ends +1.0 mm∗ 0 Through-holes 50 to 500 mm/s 50 to 300 mm/s Stroke length tolerance Mounting Piston speed ∗ Stroke length tolerance does not include the amount of dumper change. Standard Stroke Do not use the product as...
Open the catalog to page 3Plate Non-rotating Accuracy Non-rotating accuracy without load is designed to be same or less than the figures shown in the table below at the retracted cylinder end (plate). Bore size (mm) Non-rotating accuracy Plate Allowable Rotational Torque Make sure to operate strictly within the allowable rotation torque range to the plate. Operation outside of this range may result in shorter service life or damage to the devise. Plate Allowable Lateral Load Allowable Kinetic Energy Make sure to operate strictly within the allowable lateral load range to the plate. Make sure to operate strictly within...
Open the catalog to page 4Compact Cylinder: Guide Rod Type Construction ø12 to ø25 With auto switch (Built-in magnet) ø32 to ø100 With auto switch (Built-in magnet) Description Cylinder tube Aluminum alloy Hard anodized Aluminum alloy Aluminum alloy casted Aluminum alloy Stainless steel Carbon steel ø32 to ø100 Hard chrome plated Aluminum alloy Stainless steel Hard chrome plated Oil-impregnated sintered alloy Bearing alloy Hexagon socket head cap screw Carbon steel Nickel plated Hexagon socket head cap screw Retaining ring Piston seal Carbon steel Nickel plated Carbon tool steel Phosphate coated Individual -X Technical...
Open the catalog to page 5Mounting Bolt Mounting method: Mounting bolt for through-hole style of CQMB is available as an option. Ordering: Add the word “Bolt” in front of the bolts to be used. Mounting bolt Example) Bolt M3 x 25L 2 pcs. Material: Chromium molybdenum steel Surface treatment: Nickel plated Note) To install a cylinder with bore size 12 to 25 mm with through-hole, be sure to use the attached flat washer. Mounting Bolt for CQM/Without Auto Switch Cylinder model Mounting bolt size M3 x 25L x 30L x 35L x 40L x 45L x 50L M3 x 25L x 30L x 35L x 40L x 45L x 50L M5 x 25L x 30L x 35L x 40L x 45L x 50L x 55L x 60L...
Open the catalog to page 6Compact Cylinder: Guide Rod Type Mounting Bolt for CDQM/With Auto Switch (Built-in magnet) Cylinder model Mounting bolt size M3 x 30L x 35L x 40L x 45L x 50L x 55L M3 x 30L x 35L x 40L x 45L x 50L x 55L M5 x 35L x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L M5 x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L Mounting bolt size M5 x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 110L x 135L M5 x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 115L x 140L M6 x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 90L x 95L x 120L x 145L Mounting bolt size M8 x 60L...
Open the catalog to page 72 x 2 x øOB counterbore with depth RB Stroke range Without auto switch With auto switch (mm) A B A B Note) For the following bore/stroke sizes, the through-hole is threaded. Standard without auto switch: ø12 and ø16; 5 stroke, ø20; 5 to 15 stroke, ø25; 5 and 10 stroke, Built-in magnet with auto switch: ø20; 5 stroke
Open the catalog to page 8Compact Cylinder: Guide Rod Type Dimensions ø32 to ø50 2 x HA through 2 x øHB through Auto switch 2 xøN through 2 x 2 x øOB counterbore with depth RB CQS Both ends tapped (CQMA) CQ2 RQ (mm) Without auto switch Bore size (mm) With auto switch D- -X Individual -X Technical data
Open the catalog to page 92 x øN through 2 x 2 x øOB counterbore with depth RB Auto switch Both ends tapped (CQMA) (mm) Without auto switch With auto switch Bore size (mm)
Open the catalog to page 10Compact Cylinder: Guide Rod Type Minimum Auto Switch Mounting Stroke (mm) Bore size (mm) Auto switch No. model of auto D-M9V D-A9V switch mounted ∗ D-P4DWL type is compatible with bore sizes ø40 to ø100. Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A9 D-M9 ø12 Proper Auto Switch Mounting Positions Auto switch model Bore size Auto Switch Mounting Height Auto switch model Bore size Note 1) ( ): For D-A93 type Note 2) W is used for mounting D-A9, D-M9, D-M9W and D-M9AL types. Note 3) Negative figures for W in the table indicate that an auto switch is mounted...
Open the catalog to page 11Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-A7 D-A80 D-A73C D-A80C D-A79W Proper Auto Switch Mounting Position Auto switch model Bore size ∗ D-P4DWL type is compatible with bore sizes ø40 to ø100. Note) Adjust the auto switch after confirming the operating condition in the actual setting. Auto Switch Mounting Height Auto switch model Bore size Bore size ∗ Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming approximately ±30% dispersion). It may vary substantially depending on an ambient environment....
Open the catalog to page 1267 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages