Compact Cylinder Remodeled with a new body to get more flexibility! Can mount small auto switches on 4 surfaces. Auto switches can be mounted on any of the 4 surfaces, depending on the installation conditions. (ø12 to ø25: 2 surfaces) Improved flexibility of system design. Auto switch mounting rail removed NEW A round slot for mounting small auto switches Available up to ø200 is provided on 4 surfaces. ø32 to ø50 : Only one surface Existing model NEW ø32 to ø200 Auto switch rail Rail mounting type auto switch Small auto switch ø25: Mountable on 2 surfaces 2 switches can be mounted on the same surface. (ø12: One slot for each surface) No projection of auto switch Existing model ˾ Prevention of damage to auto switch ˾ Sleeves cannot get caught in the auto switch and its mounting rail. Improved ease of work and safety ˾ Reduction in labor for design There is no need to check for interference with a machine, because the outer dimensions of the cylinder do not change when the auto switch is mounted. NEW Exclusive bodies (-XB10) for ø32 to ø100 intermediate strokes (50 st or more) now kept in inventory*, enabling shorter delivery times. * Formerly produced upon receipt of order Currently stocked intermediate stroke
Open the catalog to page 1Compact Cylinder (Compared with SMC CQ2 series) Existing model Lighter weight Weight (Stroke 50 mm, built-in magnet, female thread and with (g) rubber bumper) The body strength (kinetic energy, allowable load, withstand pressure, etc.) is the same as the existing product. Contribution to environment and ecology Bore size – Stroke NEW ø40-50 st 456(483) 483(527) ( ): With male thread Reduction of CO2 discharge by 1300 t by less use of aluminum 2-color indication solid state auto switch Appropriate setting of the mounting position can be performed without mistakes. Operating range Small auto switch...
Open the catalog to page 2˾ Reduction in number of components ˾ No loss of components Reduction in labor for work Auto switch 1 Insert the auto switch. ˾ Takes a lot of labor and time Existing model because there are many components. ˾ Highly likely to lose components Auto switch The nuts and screws may fall out when installed vertically. Auto switch ˾ The auto switch can be replaced with the foot brackets mounted. Reduction in labor for design Auto switch Auto switch Existing model The bracket does not interfere with the slot. Port side Auto switch side The bracket interferes with the slot. Auto switch side Port side...
Open the catalog to page 3Compact Cylinder Series CQ2 With a short overall length, the space-saving cylinder helps to make various jigs and equipment more compact. Series Variations Double acting Double rod CQ2W Single acting Large Bore Size Spring return/ Spring extend Double acting CQ2KW Axial Piping (Centralized piping type) Double acting Single acting Anti-lateral Load Double acting Double acting Spring return/ Spring extend Double acting Long Stroke Axial Piping Anti-lateral Load Water Resistant With Auto Switch Large Bore Size NEW Smooth Cylinder (Low friction) Refer to Best Pneumatics No. 3. Low-speed Cylinder...
Open the catalog to page 4Combinations of Standard Products and Made Note 1) 012 with auto switch: With rubber bumper (Standard) Note 4) 012 to 032: (O), for 040 to 063 only Note 2) With rubber bumper (Standard) Note 5) 012: (-) Note 3) 012 to 016: (O), for 020 to 0100 only (up to 050 for single acting type) Note 6) 020 to 032: (O), for 040 to 0100 only
Open the catalog to page 5Note 7) 020 to 025: (O), for 032 to 0100 only □ Note 10) With boss on rod end (Standard)D Note 8) Rod end lock: (-), for head end lock onlyD Note 11) 0180 to 0200: (O), for 0125 to 0160 onlyD Note 9) Head end lock: (-), for rod end lock only Note 12) The body shape is the same as the existing product.
Open the catalog to page 6Compact Cylinder: Standard Double Acting, Single Rod Without auto switch ø32 to ø100 With auto switch Auto switch With auto switch (Built-in magnet) Without auto switch Nil ∗ Refer to the below table for Through-hole (Standard) Both ends tapped Foot applicable auto switches. Rod flange Head flange Double clevis Auto switch mounting groove Z ∗ Mounting brackets are shipped together, (but not assembled). ∗ Cylinder mounting bolts are not included. Order them Pneumatic Air-hydro Note 1) Body option Bore size Port thread type Refer to the next page for details. Note 1) Bore sizes available for airhydro...
Open the catalog to page 7Compact Cylinder: Standard Double Acting, Single Rod Made to Order (For details, refer to pages 177 to 207.) Heat resistant cylinder (–10 to 150°C) w/o auto switch only Note) Stroke length tolerance does not include the amount of bumper change. Air-hydro type Bore size (mm) Action Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Stroke length tolerance Double acting, Single rod Turbine oil Note) 1.5 MPa 1.0 MPa 0.18 MPa 0.1 MPa 5 to 60°C 5 to 50 mm/s None +1.0 mm 0 Note) Refer to “Handling Precautions for SMC Products”...
Open the catalog to page 8Series CQ2 Manufacture of Intermediate Strokes (Except air-hydro type) 1. Spacer-installed type 1: Standard model number Intermediate stroke with : Available in 1 mm intervals A spacer is installed on tubes with a stroke longer than the specified stroke ( Bore size (mm) : Standard stroke Ordering example (when ordering ø32-57 mm stroke (with through-hole (standard), without switch) Type Part no. 1. Spacer-installed type 1 Standard model number CQ2B32-57DZ (uses 75 mm stroke tube) Order no. • CQ2B32-75DZ with 18 mm width spacer inside • The B dimension is 108 mm. 2. Spacer-installed type 2: Suffix...
Open the catalog to page 9Compact Cylinder: Standard Double Acting, Single Rod Allowable Kinetic Energy Allowable Lateral Load at Rod End Load Mass and Piston Speed Without Auto Switch Mass of Cylinder Movable Parts/Without Built-in Magnet Bore size (mm) Large Bore Size m1: Mass of cylinder movable parts m2: Load mass V: Piston speed Long Stroke Mass of Cylinder Movable Parts/With Built-in Magnet Cylinder stroke (mm) If an allowable lateral load at rod end is exceeding the value in the graph, we recommend anti-lateral load type cylinder be used. (Mounting orientation: Horizontal) With Auto Switch Axial Piping Anti-lateral...
Open the catalog to page 1067 Pages
60 Pages
17 Pages
26 Pages
25 Pages
5 Pages
64 Pages
12 Pages
4 Pages
49 Pages
2 Pages
8 Pages
252 Pages
70 Pages
18 Pages
48 Pages
82 Pages
41 Pages
60 Pages
272 Pages
23 Pages
60 Pages
60 Pages
36 Pages
252 Pages
88 Pages
18 Pages
214 Pages
108 Pages
198 Pages
92 Pages
82 Pages
24 Pages
8 Pages
43 Pages
25 Pages
12 Pages
10 Pages
8 Pages
7 Pages
5 Pages
59 Pages
2 Pages
4 Pages
44 Pages
10 Pages
17 Pages
29 Pages
16 Pages
32 Pages
9 Pages
85 Pages
52 Pages
28 Pages
35 Pages
75 Pages
37 Pages
59 Pages
62 Pages
58 Pages
18 Pages
24 Pages
103 Pages
59 Pages
175 Pages
12 Pages
47 Pages
59 Pages
74 Pages
27 Pages
27 Pages
30 Pages
78 Pages
37 Pages
127 Pages
38 Pages
10 Pages
22 Pages
11 Pages
54 Pages
15 Pages
63 Pages
152 Pages
91 Pages
96 Pages
5 Pages
32 Pages
1 Page
7 Pages
16 Pages
80 Pages
80 Pages
80 Pages
16 Pages
3 Pages
14 Pages
13 Pages
32 Pages
44 Pages
117 Pages
23 Pages
44 Pages
30 Pages
51 Pages
20 Pages
65 Pages
7 Pages
17 Pages
89 Pages
16 Pages
50 Pages
27 Pages
12 Pages
32 Pages
36 Pages
41 Pages
158 Pages
175 Pages
31 Pages
52 Pages
12 Pages
37 Pages
14 Pages
16 Pages
138 Pages
25 Pages
50 Pages
16 Pages
4 Pages
11 Pages
18 Pages
88 Pages
13 Pages
53 Pages