Catalog excerpts
Air Management System Sustainability – Condition Based Maintenance - Digitalization Standby regulator Residual pressure relief valve Switch pressure between operation and standby Secondary air supply or shut-off (exhaust) switching Wireless adapter (Accessories p. 46 ) Air management hub Flow rate, pressure, and temperature sensing Communication function ∗1 In SMC conditions: M aximum reduction ratio within product specifications (at 0.7 MPa operating pressure and 0.2 MPa low pressure) Monitors the machine standby conditions (when production stops) and automatically decreases the pressure. Reduces unnecessary air consumption Compatible with Direct connection enables data communications. Compatible with Compatible with SMC wireless systems ¡Communication cables not required ¡High security using unique encryption ¡Communication distance: Max. 100 m
Open the catalog to page 1Air Management System AMS20/30/40/60 Series Why not reduce the wasted air generated by your factory equipment? Blow and purge in equipment standby Leakage from piping connections due to poor piping installation Leakage from cylinder due to worn seals Reduce air consumption by lower pressure during equipment standby Standby mode Example Under equipment operating conditions: Pressure 0.5 MPa, air consumption 1800 L/min and idle air consumption 200 L/min, then Standby Mode can apply low pressure setting 0.2 MPa to equipment. Transition of equipment operating status Machine operating Monitoring...
Open the catalog to page 2Air Management System AMS20/30/40/60 Series Visualization of production equipment status Flow, pressure, temperature, and other sensor information can be communicated to the host system via Industrial Ethernet or the OPC UA data communication Host system protocol. Equipment status can be monitored from another location or from outside the office. User cloud Direct connection Edge server Direct connection Pressure switch Solenoid valve IoT gateway Direct connection OPC UA (OPC Unified Architecture) is an open communication standard that facilitates direct data exchange and information...
Open the catalog to page 3Air Management System AMS20/30/40/60 Series Compatible with SMC wireless systems∗1 ∗1 When connecting a wireless adapter (sold separately) 01 ¡No communication cable required between the base and remote Reduced wiring work, space, and cost Minimized disconnection risk High security using encryption Unauthorized access is prevented by using data encryption. Base Compact Wireless 0 1 00 Remote 11 More information 10 can be viewed EXW1 Series here. 0 0 11 Retrofitted 00to existing equipment 11 0 Can be introduced by0 1OPC UA or the wireless system 1 without connecting to a0 0PLC or changing...
Open the catalog to page 4Air Management System AMS20/30/40/60 Series System Configuration Port size Series Electro-Pneumatic Regulator Type Communication protocol Output data I · nstantaneous flow · ccumulated flow A · ressure P F · luid temperature · arious sensor V information transmitted via IO-Link · iagnosis D Regulator Type Components Air Management Hub When connected to a wireless adapter, it has the ability to communicate with upper level system and wireless communication. Standby regulator and residual pressure exhaust valve are connected to control the air management system. Upper Communication Type...
Open the catalog to page 5Air Management System AMS20/30/40/60 Series Components Standby Regulator Based on the signal from the air management hub, the operating mode shifts to standby mode and regulates the pressure to the standby pressure. The non-relief type allows efficient use of air by not exhausting secondary-side air during the standby mode transition. Electro-Pneumatic Regulator Type Regulator Type ¡ emote pressure setting and switching R during equipment startup/shutdown ¡ elect from normally closed or S normally open. ¡With backflow function ¡ ith pressure ramp up duration setting W function ¡ anual...
Open the catalog to page 6Air Management System AMS20/30/40/60 Series Air Management System AMS20/30/40/60 Series Air Management System Electro-Pneumatic Regulator Type AMS20A/30A/40A/60A Series Air Management System Regulator Type AMS20B/30B/40B/60B Series How to Order………………………………………………………………………………………………… p. 13 Standard Specifications…………………………………………………………………………………… p. 14 How to Order…………………………………………………………………………………………………… p. 7 Standard Specifications……………………………………………………………………………………… p. 8 Flow Rate Characteristics……………………………………………………………………………… p. 9, 15 Dimensions Standby Regulator AR20S to 50S Series How to...
Open the catalog to page 7Air Management System Electro-Pneumatic Regulator Type Body size Pipe thread type Without attachments Without attachments Port size Standalone (When wireless adapter is connected∗3: Wireless remote) PROFINET, OPC UA (When wireless adapter is connected∗3: Wireless base) EtherNet/IPTM, OPC UA (When wireless adapter is connected∗3: Wireless base) EXA1/ITV: Units selection function Manual override ∗1 Applies to overseas destinations only ∗2 Fixed units nstantaneous flow L/min I : Accumulated flow : L Pressure : kPa, MPa Temperature : °C ∗3 The wireless adapter is sold separately. (Refer to page...
Open the catalog to page 8All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages