ACG series
25Pages

{{requestButtons}}

Catalog excerpts

ACG series - 1

Standard Combinations Air Filter + Regulator with Built-in Pressure Gauge + Lubricator Filter Regulator with Built-in Pressure Gauge + Lubricator Air Filter + Regulator with Built-in Pressure Gauge Air Filter + Mist Separator + Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge + Mist Separator I Regulator with Built-in Pressure Gauge Regulator with Built-in Pressure Gauge Regulator with Built-in Pressure Gauge with Back Flow Mechanism I Filter Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge with Back Flow Mechanism

Open the catalog to page 1
ACG series - 2

Body size . Note 1) Wall mount is not available for size 20 J) regulator with downward facing handle in B combination. Contact SMC when wall mount Note 2) The number inside ( indicates the combination order counted from the inlet Thread type« Note 3) Drain guide is NPT1/8 for ACG20 and NPT1/4 for J) ACG30 and 40. Auto-drain port is provided with 03.8" One-touch fitting (applicable to ACG30 and Note 4) Drain guide is G1/8 for ACG20 and G1/4for Port size When more than one specification is required, indicate in ascending alphanumeric Mounting angle of pressure gauge 0 • When more than one...

Open the catalog to page 2
ACG series - 3

Accessory/Optional Combinations © Combination available I I: Combination not available Q: Varies depending on a model A: Available only with NPT thread Port size Check valve Pressure switch Residual pressure relief Prevents back flow from lubricator. Compact switch Releases residual pressure in lines. Refer to page 18 for spacers and brackets

Open the catalog to page 3
ACG series - 4

Air Filter + Regulator + Lubricator Standard Specifications Air filter Reaulator Lubricator Nute I) Cui Itdut SMC leycmJiny the uuinieul luii thiedd NPT and piessuie yduye supply fui PSI uilit specifications. { n Nute 2) Minimum upeidtiny piessuie. N.O. type u. MPd, N.C. type u.ib MPa (AD17/2/). Cunteaut SMC leycmJiny the specifications fui PSI unit and "F. Nute 3) For FR I units, port tildes nut in ) die for stcmdcmJ application. Nute 4) Sepdiate spaueis die iequiied foi mudulai unit, Nute b) Piessuie switch udiiiiut be mounted UII the iiilet and outlet sides of an ARG v^ith cm upwaid...

Open the catalog to page 4
ACG series - 5

Flow Characteristics Condition: Inlet pressure 0.7 MPa Flow rate (tfmin (ANR)) Pressure Characteristics Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 e/min (ANR) A Specific Product Precautions 1. When mounting a check valve, make sure the arrow (IN side) points in the correct direction of air flow. 1. Float type auto-drain Operate under the following conditions to avoid malfunction. • Operating compressor: 0.75 kW (100 ^min (ANR)) or more. When using 2 or more auto-drains, multiply the value above by the number of auto-drains to find the capacity of the...

Open the catalog to page 5
ACG series - 6

Series ACG20/30/40 Dimensions ACG20 Standard ACG30/40 Standard Downward facing handle Downward facing handle L H1 OUT H2 2-L SMC OUT B 2-K M Port size Port size N Drain Lubricator D Regulator Min. clearance for maintenance B 4-L Min. clearance for maintenance D M 4-K Air filter G C 2ø OUT SMC IN H2 H1 J IN P L 2-ø G P C E A F E A F Drain Air filter Regulator Lubricator ACG20 Optional (-Y) ACG30/40 Optional (-Y) Upward facing handle Upward facing handle P P L H1 H1 2- C øL 2-ø OUT IN OUT SMC IN G G C E A F E A F Port size H2 2-L H2 J M 4-K OUT 2-K B B 4-L SMC OUT M Port size Regulator...

Open the catalog to page 6
ACG series - 7

Filter Regulator + Lubricator Standard Specifications Filter regulator Lubricator —— Note 1) Contact SMC regarding the connection thread NP I and pressure gauge supply tor PSI unit specifications. f yi Note 2) Minimum operating pressure: N.U. type 0. MPa; IN .(J. type 0.15 MPa (AD17/27). Contact SMC regarding the PSI and uh unit specifications. \w/ Note 3) hor h.KL. units, port sizes not in ) are tor standard application. Note 4) Separate spacers are required tor modular unit.

Open the catalog to page 7
ACG series - 8

^ | Filter regulator! I Lubricator! Applicable model specif icatbns With auto-drain (N.C.) Metal bowl With drain guide With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting idth across Hats 17 Barb fitting Accessory/Optional specifications Note) For the accessory/optional specifications (with auto-drain, with barb fitting, with drain guide, metal bowl, or with level gauge), the total length (B dimension) will vary.

Open the catalog to page 8
ACG series - 9

Standard Specifications Nulfc I) (Juilldut bMU leydidhiy piessuie yciuyt supply tOl Prfl uillt apeCltlUdtlOrib. Nuib 2) Minimum upeidtiny pie&&uie. N.O. Typu u. MPd, N.O. type u.ioMPa (Junket bMU leydidiny the PSI and "h unit opeciti^dtiorifc " ■* NuTB 3) Sepdiaie spciueis die leqUlled tOi muduldi uillt. NuTB 4) Piessuie switch udiniut be muunied uii the nilei and outlet dideb ot an AhG vv"ith mi upwdid taciny handle (optional specification.

Open the catalog to page 9
ACG series - 10

Series ACG20B/30B/40B Dimensions ACG20B Standard ACG30B/40B Standard Downward facing handle Downward facing handle IN OUT G OUT SMC M 2-K P H1 IN B B 2-L SMC H2 H1 J C G N øL H2 P øL E C E A N L A Port size M K Port size Drain Regulator D Air filter Min. clearance for maintenance D Min. clearance for maintenance o s Drain Air filter Regulator ACG20B Optional (-Y) ACG30B/40B Optional (-Y) Upward facing handle Upward facing handle A A P H1 H2 H1 J OUT SMC OUT L 2-L IN H2 C G øL øL SMC M 2-K B B P G C E IN N E N Port size M K Port size Drain Regulator D Air filter Drain Air filter Regulator...

Open the catalog to page 10
ACG series - 11

Air Filter + Mist Separator + Regulator Standard Specifications Air filter Regulator Lubricator Nuie1)Pi u./MPa u 3 MPa setting and fully upon Jj Nute 2) At uumpressur dibuharge mgf/Nlrl3 Note 1) Uontact SMU regarding pressure gauge supply tor PSI unit specifications. J\ Note 2) Minimum operating pressure: N.O. type 0.1 MPa; N.U. type 0.15 MPa. Uontact SMU regarding the Pol and uh unit specification Note 3) Separate spacers are required tor modular unit. Note 4) Pressure switch cannot be mounted on the inlet and outlet sides ot an AHU with an upward facing handle (optional specification: -Y).

Open the catalog to page 11

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. HRS series

    47 Pages

  48. LES

    59 Pages

  49. MHS

    74 Pages

  50. MHY

    27 Pages

  51. MHC

    27 Pages

  52. MHR

    30 Pages

  53. MHZ series

    78 Pages

  54. MSQ

    37 Pages

  55. MGP

    127 Pages

  56. MXS

    38 Pages

  57. NRB

    10 Pages

  58. MXW

    22 Pages

  59. MHT

    11 Pages

  60. MY3

    54 Pages

  61. CQM

    15 Pages

  62. NCA1

    63 Pages

  63. CM2

    152 Pages

  64. NCM

    91 Pages

  65. NCG

    96 Pages

  66. NCRA1

    5 Pages

  67. CS2

    32 Pages

  68. T/TIA

    1 Pages

  69. KR

    7 Pages

  70. KF

    16 Pages

  71. KQ

    80 Pages

  72. AFF

    80 Pages

  73. AMG

    80 Pages

  74. IDF

    16 Pages

  75. HAA

    3 Pages

  76. ZFA

    14 Pages

  77. ZA

    13 Pages

  78. MHF

    32 Pages

  79. CRB

    44 Pages

  80. D

    117 Pages

  81. RB

    23 Pages

  82. CEP

    44 Pages

  83. rsq

    30 Pages

  84. CLK

    51 Pages

  85. MK

    20 Pages

  86. CLJ

    65 Pages

  87. MGJ

    7 Pages

  88. ZSE30A

    17 Pages

  89. IDFB*E

    89 Pages

  90. ISE10

    16 Pages

  91. ITV1000/2000

    50 Pages

  92. AW

    27 Pages

  93. NVFM200

    12 Pages

  94. NVM100

    32 Pages

  95. LLA*A

    36 Pages

  96. VX3*

    41 Pages

  97. SY3000

    158 Pages

  98. CH(D)2

    175 Pages

  99. LEHZ

    82 Pages

  100. M(D)SUB

    31 Pages

  101. CXSJ

    58 Pages

  102. CY3B

    39 Pages

  103. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. Shock Absorber

    16 Pages

  5. Silencer

    4 Pages