Group: SMC
ACG/ARG/AWG Series - Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge
44Pages
Catalog excerpts
Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge Transparent bowl guard Improved environmental durability due to 2-layer construction * Body size 30 or more Improved visibility by mounting the pressure gauge on the top of the knob Installation at lower locations ACG/ARG/AWG Series Installation at higher locations
Open the catalog to page 1Regulator with Built-in Pressure Gauge/Filter Regulator with Built-in Pressure Gauge ACG/ARG/AWG Series Space saving, Labor saving■ Installation height: Approx. 30 mm reduction * For ARG30-B Mounting at 90° Gauge angle Mounting angle of pressure gauge is selectable depending on the piping direction * Mounting angle can be changed as desired. For details, refer to “Procedure for replacing or changing the mounting angle of a pressure gauge” on page 42. Pressure gauge, regulator, and knob are integrated into one location. Another hole for the pressure gauge was necessary Space saving ^...
Open the catalog to page 2Regulator with Built-in Pressure Gauge/Filter Regulator with Built-in Pressure Gauge ACG/ARG/AWG Series Transparent bowl guard Better environmental resistance: Transparent bowl guard can protect the inner bowl! Windows on the bowl guard have been removed and the inner bowl is instead covered with a polycarbonate transparent bowl guard. Now, even if the environment changes and the bowl is exposed to corrosive chemical or oil splash, the foreign matter will not stick directly to the pressurized bowl. This can reduce risk of bowl breakage. Transparent bowl guard Existing model Cracks may...
Open the catalog to page 3Filter Regulator with Built-in Pressure Gauge® Mist Separator
Open the catalog to page 4Regulator with Built-in Pressure Gauge ARG Filter Regulator with Built-in Pressure Gauge AWG Regulator with Built-in Pressure Gauge with Backflow Function ARGDK Filter Regulator with Built-in Pressure Gauge with Backflow Function AWGDK
Open the catalog to page 5Mounting angle of pressure gauge 0° • Semi-standard: Select one each for a to h. • Option/Attachment/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) ACG30C-F03DG1-SV1-16NR-B
Open the catalog to page 6*1 Mounting angle of pressure gauge is G1 only. If other mounting angles are needed, contact SMC. *2 Wall mount is not available for a regulator with downward facing knob. Contact SMC when wall mount is needed. *3 Drain guide is NPT1/8 (applicable to the ACG20-B) and NPT1/4 (applicable to the ACG30-B to ACG40-B). The auto drain port comes with a 03/8" One-touch fitting (applicable to the ACG30-B to ACG40-B). *4 Drain guide is G1/8 (applicable to the ACG20-B) and G1/4 (applicable to the ACG30-B to ACG40-B). *5 When pressure is not applied, condensate which does not start the auto drain...
Open the catalog to page 7Air Filter + Regulator + Lubricator Standard Specifications *1 Contact SMC regarding pressure gauge supply for psi unit specifications. *2 Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27-A) and 0.15 MPa for N.C. type (AD37-A and AD47-A). Contact SMC for psi and °F specifications. *3 For F.R.L. units, port sizes not in ( ) are for standard application. *4 Separate spacers are required for modular unit. *5 Pressure switch cannot be mounted on the inlet and outlet sides of an ARG-B with an upward facing knob (semi-standard specification: -Y).
Open the catalog to page 8Flow Rate Characteristics Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 L/min (ANR) Flow rate [L/min (ANR)] Specific Product Precautions Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. units precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual” on the SMC website: https://www.smcworld.com Piping 1. hen mounting a check valve, make sure the arrow (IN side) W points in the correct direction of air flow. 1. f a...
Open the catalog to page 9Dimensions ACG20-B Standard Downward facing knob A ACG30-B, ACG40-B Standard Downward facing knob A ACG20-B Semi-standard (-Y) Upward facing knob Applicable model With auto drain Metal bowl With drain guide Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb Wing Semi-standard specifications * 1 In the case of the ACG20-B’s standard specification (downward facing knob), the wall mounting is not possible using the lower side mounting hole on the spacer with a bracket. Use the upper side mounting hole when wall mounting. *2 In the case of the upward facing knob in the...
Open the catalog to page 10Filter Regulator + Lubricator *1 Contact SMC regarding pressure gauge supply for psi unit specifications. *2 Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27-A) and 0.15 MPa for N.C. type (AD37-A and AD47-A). Contact SMC for psi and °F specifications. *3 For F.R.L. units, port sizes not in ( ) are for standard application. *4 Separate spacers are required for modular unit.
Open the catalog to page 11Port size Drain Filter regulator Drain Filter regulator Width across flats 14 Metal bowl with level gauge With drain guide Thread type/Rc, G: ø10 One-touch fitting Thread type/NPT: ø3/8" One-touch fitting Drain cock with barb fitting Metal bowl With auto drain (N.O./N.C.) Applicable model ACG20A-B Optional/Semi-standard specifications With auto drain Metal bowl With drain guide Port size 1/4 Width across flats 17 Barb fitting applicable tubing: T0604 Standard specifications Model Semi-standard specifications*2 With barb fitting With drain guide Metal bowl Bracket mount Metal bowl with level...
Open the catalog to page 12*1 Contact SMC regarding pressure gauge supply for psi unit specifications. *2 Minimum operating pressure: 0.1 MPa for N.O. type, 0.1 MPa for N.C. type (AD27-A) and 0.15 MPa for N.C. type (AD37-A and AD47-A). Contact SMC for psi and °F specifications. *3 Separate spacers are required for modular unit. *4 Pressure switch cannot be mounted on the inlet and outlet sides of an ARG-B with an upward facing knob (semi-standard specification: -Y).
Open the catalog to page 13Downward facing knob ACG30B-B, ACG40B-B Standard Downward facing knob AN ACG20B-B Semi-standard (-Y) Upward facing knob ACG30B-B, ACG40B-B Semi-standard (-Y) Upward facing knobA N P G Model * 1 In the case of the ACG20B-B’s standard specification (downward facing knob), the wall mounting is not possible using the lower side mounting hole on the spacer with a bracket. Use the upper side mounting hole when wall mounting. *2 In the case of the upward facing knob in the semi-standard specification, the C dimension will change. Also, in the case of the ACG20B-B, wall mounting is possible by...
Open the catalog to page 14All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
AC10-A to AC40-A
82 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages