Catalog excerpts
Modular F.R.L. Units AC Series RoHS Better visibility and environmental resistance Double layer design The bowl is covered with a transparent bowl guard! ¡The inside is visible from 360°. ¡The bowl is completely protected from the environment. Safety improved Inner bowl Transparent bowl guard Material: Polycarbonate Material: Polycarbonate ∗ Body size: 30 or more Energy saving regulator Pressure drop: Max. Easy replacement of the element Reduced required maintenance space The element and the bowl are in one piece. Replacement can be done in hand. Body size 10, 50, 60 added! AR Size 10 Regulator Lubricator Mist Separator Filter Regulator Filter Regulator Current model Mist Separator Air Filter
Open the catalog to page 1AC Series Transparent bowl guard Better environmental resistance: Transparent bowl guard can protect the inner bowl! Windows on the bowl guard have been removed and the inner bowl is instead covered with a polycarbonate transparent bowl guard. Now, even if the environment changes and the case is exposed to corrosive chemical or oil splash, the foreign matter will not stick directly to the pressurized bowl. This can reduce risk of bowl breakage. Double layer Current design Transparent bowl guard Applicable model Air Filter AF Cracks may occur in a portion where the internal pressure is...
Open the catalog to page 2Series Configuration Filter Regulator (+ Lubricator
Open the catalog to page 3Series Configuration Product
Open the catalog to page 4Modular F.R.L. Units AC Series Simple Specials System Simple /O A system designed to respond quickly and easily to your special ordering needs pedals System / Short lead times This system enables us to respond to your special needs, such as additional machining, accessory assembly, or modular unit, and deliver such special products as quickly as standard products. Repeat orders Once we receive a Simple Special part number from your previous order, we will process the order, manufacture the product, and deliver it to you. Please contact your local sales representative for more details.
Open the catalog to page 5AC Series Attachment List Check valve A check valve with intermediate branch port can be easily installed to prevent a backflow of lubricant when branching the air flow and releasing the air on the outlet side of the regulator. Pressure switch A compact integrated pressure switch can be easily installed and facilitates the pressure detection of the line. Pressure switch Using a T-shaped spacer facilitates the branching of air flow. Applicable series Pipings are possible in all 4 directions. · Air Filter + Regulator + Lubricator (AC20-A to AC40-A) · Filter Regulator + Lubricator...
Open the catalog to page 6Pressure switch with piping adapter Accessories (Spacer/Spacer with bracket) Spacer with bracket Pressure switch with piping adapter Spacer with bracket * Needs to be ordered separately. * Needs to be ordered separately. Related Product Modular adapter Easy modular connections for all equipment! Example) Air filter + 3 port valve AF 3 port valve Modular adapter (E310-U02) Spacer with bracket (Y300T-A) Air filter (AF30-
Open the catalog to page 7Air Combination Air Filter + Regulator + Lubricator • Option/Semi-standard: Select one each for a to m. • Option/Attachment/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30-F03DM-KSTV-13NR-A
Open the catalog to page 8Note 1) Drain guide is NPT1/8 (applicable to the AC20-A) and NPT1/4 (applicable to the AC25-A to AC40-A). The auto drain port comes with 03/8” One-touch fitting (applicable to the AC25-A to AC40-A). Note 2) Drain guide is G1/8 (applicable to the AC20-A) and G1/4 (applicable to the AC25-A to AC40-A). Note 3) Option G, M are not assembled and supplied loose at the time of shipment. Note 4) When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. Note...
Open the catalog to page 9AC10-A to AC40-A Series Flow Rate Characteristics (Representative values) AC10-A Flow rate L/min (ANR) Conditions: Inlet pressure 0.7 MPa, Outlet pressure 0.2 MPa, Flow rate 20 L/min (ANR) Flow rate L/min (ANR) Pressure Characteristics (Representative values) Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) Flow rate L/min (ANR) Condition: Inlet pressure 0.7 MPa
Open the catalog to page 10Be sure to read this before handling the products. Refer to back page 50 for Safety Instructions and pages 387 * to 391 for F.R.L. Precautions. LI 1. When mounting a check valve, make sure the arrow (IN side) points in the correct direction of air flow. |Air Supply| Caution 1. Use an air filter with 5 ^m or less filtration rating on the inlet side of the valve to avoid any damage to the seat caused by dust when mounting a pressure relief 3 port valve on the inlet side. |Mounting/Adjustment| Caution 1. When the bowl is installed on the air filter, filter regulator, lubricator, mist...
Open the catalog to page 11Pressure gauge (Option) Pressure gauge (Option) Metal bowl With drain guide With auto drain (N.C.) (Pressure gauge port size) Applicable model Optional/Semi-standard specifications (Pressure gauge port size) Metal bowl with drain guide With auto drain (N.O./N.C.) Width across flats 14 Width across flats 14 Thread type/Rc, G: ø10 One-touch fitting Thread type/NPT: ø3/8" One-touch fitting Width across flats 17 Width across flats 17 With drain guide Metal bowl with level gauge, with drain guide Drain cock with barb fitting Width across flats 17 Metal bowl with level gauge Metal bowl with drain...
Open the catalog to page 12Air Combination Filter Regulator + Lubricator • Option/Semi-standard: Select one each for a to l. • Option/Attachment/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30A-F03DM-KSV-13NR-A
Open the catalog to page 13Note 1) Drain guide is NPT1/8 (applicable to the AC20A-A) and NPT1/4 (applicable to the AC30A-A to AC40A-A). The auto drain port comes with o3/8" One-touch fitting (applicable to the AC30A-A to AC40A-A). Note 2) Drain guide is G1/8 (applicable to the AC20A-A) and G1/4 (applicable to the AC30A-A to AC40A-A). Note 3) Option G, M are not assembled and supplied loose at the time of shipment. Note 4) When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is...
Open the catalog to page 14All SMC Corporation of America catalogs and technical brochures
-
Aluminum High Vacuum Angle Valve
26 Pages
-
AP Ultra High Purity
25 Pages
-
IFW5 series
5 Pages
-
Air Management System
64 Pages
-
25A-ZSE20(F)/ISE20 Series
12 Pages
-
ASG
4 Pages
-
IDG
49 Pages
-
CXSJ_M
2 Pages
-
JLV20/30
8 Pages
-
Series NCQ2/CQ2
252 Pages
-
AC Series - Modular F.R.L. Units
70 Pages
-
KQG2
18 Pages
-
IDF*E
48 Pages
-
VQZ115, 100 Series
41 Pages
-
SYJ300
60 Pages
-
3000 Series
272 Pages
-
MTS8
23 Pages
-
CXS-A
60 Pages
-
CXSL
60 Pages
-
MXQR
36 Pages
-
NC(D)Q2-Z
252 Pages
-
LEY series
88 Pages
-
MXH series
18 Pages
-
KQ2
214 Pages
-
Modular F.R.L. Units
108 Pages
-
MXQ series
198 Pages
-
Fieldbus System
92 Pages
-
Fluoropolymer Piping Equipment
82 Pages
-
Digital Flow Switch
24 Pages
-
Vacuum Pad with Ejector
8 Pages
-
Intrinsically safe Valve
43 Pages
-
CQ2 series
25 Pages
-
IDH, Thermo-dryer
12 Pages
-
ISG
10 Pages
-
ISE3
8 Pages
-
ISE2
7 Pages
-
ISE1
5 Pages
-
ISA
59 Pages
-
IS3000
2 Pages
-
IS10/10M/10E
4 Pages
-
PSE series
44 Pages
-
ISE70/75/75H
10 Pages
-
ISE80
17 Pages
-
ISE40A
29 Pages
-
HED series
16 Pages
-
HEC series
32 Pages
-
HEB series
9 Pages
-
HRG series
85 Pages
-
HRZ series
52 Pages
-
HRW series
28 Pages
-
LQ series
35 Pages
-
LVQ series catalog
75 Pages
-
PA series
37 Pages
-
EX600, Analog Input/Output Unit
59 Pages
-
LER series
62 Pages
-
LEJ series
58 Pages
-
ISE/ZSE30A series
18 Pages
-
LAT3 series
24 Pages
-
LEH series
103 Pages
-
CQS series
59 Pages
-
CH series
175 Pages
-
ARX series
12 Pages
-
HRS series
47 Pages
-
LES
59 Pages
-
MHS
74 Pages
-
MHY
27 Pages
-
MHC
27 Pages
-
MHR
30 Pages
-
MHZ series
78 Pages
-
MSQ
37 Pages
-
MGP
127 Pages
-
MXS
38 Pages
-
NRB
10 Pages
-
MXW
22 Pages
-
MHT
11 Pages
-
MY3
54 Pages
-
CQM
15 Pages
-
NCA1
63 Pages
-
CM2
152 Pages
-
NCM
91 Pages
-
NCG
96 Pages
-
NCRA1
5 Pages
-
CS2
32 Pages
-
T/TIA
1 Pages
-
KR
7 Pages
-
KF
16 Pages
-
KQ
80 Pages
-
AFF
80 Pages
-
AMG
80 Pages
-
IDF
16 Pages
-
HAA
3 Pages
-
ZFA
14 Pages
-
ZA
13 Pages
-
MHF
32 Pages
-
CRB
44 Pages
-
D
117 Pages
-
RB
23 Pages
-
CEP
44 Pages
-
rsq
30 Pages
-
CLK
51 Pages
-
MK
20 Pages
-
CLJ
65 Pages
-
MGJ
7 Pages
-
ZSE30A
17 Pages
-
IDFB*E
89 Pages
-
ISE10
16 Pages
-
ITV1000/2000
50 Pages
-
AW
27 Pages
-
NVFM200
12 Pages
-
NVM100
32 Pages
-
LLA*A
36 Pages
-
VX3*
41 Pages
-
SY3000
158 Pages
-
CH(D)2
175 Pages
-
LEHZ
82 Pages
-
M(D)SUB
31 Pages
-
CXSJ
58 Pages
-
CY3B
39 Pages
-
C(D)Q2W-Z
208 Pages
Archived catalogs
-
ZSE1 series
12 Pages
-
Rack and Pinion Rotary Actuators
37 Pages
-
Rodless cylinder
52 Pages
-
VV061 series
11 Pages
-
Special Fittings
14 Pages
-
SX series
138 Pages
-
ACG series
25 Pages
-
C95 Pneumatic Cylinder
50 Pages
-
Toggle Grippers
16 Pages
-
Shock Absorber
16 Pages
-
Silencer
4 Pages
-
Air Filter Catalog
18 Pages
-
heavy Duty Actuators
88 Pages
-
Self-seal Fittings Catalog
13 Pages
-
Connectors Catalog
53 Pages