1. Catalogs
  2. SMC Corporation of America
  3. AC Series - Modular F.R.L. Units
video corpo
cad

AC Series - Modular F.R.L. Units
1 /70Pages

AC Series - Modular F.R.L. Units

AC Series - Modular F.R.L. Units
1 /70Pages

Catalog excerpts

AC Series - Modular F.R.L. Units-1

Modular F.R.L. Units RoHS Modular Design with Uniform Body Style Better visibility & environmental resistance 2-layer construction The bowl is covered with a transparent bowl guard! * Body size 30 or more ¡The inside is visible from 360°. ¡ he bowl is completely T protected from the environment. Safety improved Transparent bowl guard Material: Polycarbonate Inner bowl Material: Polycarbonate

 Open the catalog to page 1
AC Series - Modular F.R.L. Units-2

Modular F.R.L. Units AC Series Transparent bowl guard M Better environmental resistance: Transparent bowl guard can protect the inner bowl! Windows on the bowl guard have been removed and the inner bowl is instead covered with a polycarbonate transparent bowl guard. Now, even if the environment changes and the bowl is exposed to corrosive chemical or oil splash, the foreign matter will not stick directly to the pressurized bowl. This can reduce risk of bowl breakage. Transparent bowl guard Previous model Cracks may occur in a portion where the internal pressure is applied. Inner bowl Transparent...

 Open the catalog to page 2
AC Series - Modular F.R.L. Units-3

Modular F.R.L. Units AC Series Selection of pressure gauges Square embedded type pressure gauge Round type pressure gauge Digital pressure switch Open/close type gauge cover q pen the O gauge cover. w djust the indicator to a A specified position. e lose the gauge cover. C Open the gauge cover in the direction of the arrow with fingertips. Adjust the indicator using a flat blade screwdriver. Close the gauge cover in the direction of the arrow and push it in until it clicks in place. Easy to handle Easy to hold when unlocked Finger grip Pressure regulation while unlocked Interchangeability is...

 Open the catalog to page 3
AC Series - Modular F.R.L. Units-4

Modular F.R.L. Units AC Series Filter Regulator © Lubricator

 Open the catalog to page 4
AC Series - Modular F.R.L. Units-5

Modular F.R.L. Units AC Series Mist Separator Micro Mist Separator p. 30 ] Port size IT Interchangeable with existing model • New spacer can be connected to the existing AF-A, AR-B, AL-A, AW-B series. • Existing spacer can be connected to the new AF-D, AR(K)-D, AL-D, AW(K)-D series.

 Open the catalog to page 5
AC Series - Modular F.R.L. Units-6

Air Filter + Regulator + Lubricator TT • Option/Semi-standard: Select one each for a to i. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30-F03DE1-16NR-D

 Open the catalog to page 6
AC Series - Modular F.R.L. Units-7

Body size *1 Drain guide is NPT1/8 (applicable to the AC20-D) and NPT1/4 (applicable to the AC30-D to AC40-D). The auto drain port comes with a 03/8" One-touch fitting (applicable to the AC30-D to AC40-D). *2 Drain guide is G1/8 (applicable to the AC20-D) and G1/4 (applicable to the AC30-D to AC40-D). *3 Options G and M are not assembled and supplied loose at the time of shipment. *4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. *5 If the compressor...

 Open the catalog to page 7
AC Series - Modular F.R.L. Units-8

AC20-D to AC40-D Series Inlet pressure of 0.1 MPa Inlet pressure of 0.7 MPa Flow Rate Characteristics (Representative values) AC20-D Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics (Representative values) Inlet pressure of 0.7 MPa, Outlet pressure of 0.2 MPa, Flow rate 20 L/min (ANR)

 Open the catalog to page 8
AC Series - Modular F.R.L. Units-9

r — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — t Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. units I precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual”, https://www.smcworld.com 1. Use an air filter with 5 pm or less filtration rating on the inlet side of the valve to avoid any damage to the seat caused by dust when mounting a pressure relief 3-port valve on the inlet side. 1. When the bowl is installed on the air filter, filter regulator,...

 Open the catalog to page 9
AC Series - Modular F.R.L. Units-10

P2 (Pressure gauge port size) (Pressure gauge port size) (Pressure gauge port size)

 Open the catalog to page 10
AC Series - Modular F.R.L. Units-12

Filter Regulator + Lubricator • Option/Semi-standard: Select one each for a to i. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30A-F03DE1-16NR-D

 Open the catalog to page 12
AC Series - Modular F.R.L. Units-13

*1 Drain guide is NPT1/8 (applicable to the AC20A-D) and NPT1/4 (applicable to the AC30A-D to AC40A-D). The auto drain port comes with a 03/8" One-touch fitting (applicable to the AC30A-D to AC40A-D). *2 Drain guide is G1/8 (applicable to the AC20A-D) and G1/4 (applicable to the AC30A-D to AC40A-D). *3 Options G and M are not assembled and supplied loose at the time of shipment. *4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. *5 If the compressor...

 Open the catalog to page 13
AC Series - Modular F.R.L. Units-14

P2 (Pressure gauge port size) (Pressure gauge port size) (Pressure gauge port size)

 Open the catalog to page 14
AC Series - Modular F.R.L. Units-16

AC130B 03DE 6 © © © • Option/Semi-standard: Select one each for a to h. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30B-F03DE1-16NR-D

 Open the catalog to page 16
AC Series - Modular F.R.L. Units-17

*1 Drain guide is NPT1/8 (applicable to the AC20B-D) and NPT1/4 (applicable to the AC30B-D to AC40B-D). The auto drain port comes with a 03/8" One-touch fitting (applicable to the AC30B-D to AC40B-D). *2 Drain guide is G1/8 (applicable to the AC20B-D) and G1/4 (applicable to the AC30B-D to AC40B-D). *3 Options G and M are not assembled and supplied loose at the time of shipment. *4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. *5 If the compressor...

 Open the catalog to page 17
AC Series - Modular F.R.L. Units-18

(Pressure gauge port size) (Pressure gauge port size) (Pressure gauge port size)

 Open the catalog to page 18

All SMC Corporation of America catalogs and technical brochures

  1. LEHZ

    67  Pages

  2. CXSJ

    60  Pages

  3. CY3B

    17  Pages

  4. IFW5 series

    5  Pages

  5. ASG

    4  Pages

  6. IDG

    49  Pages

  7. CXSJ_M

    2  Pages

  8. JLV20/30

    8  Pages

  9. Series NCQ2/CQ2

    252  Pages

  10. KQG2

    18  Pages

  11. IDF*E

    48  Pages

  12. SYJ300

    60  Pages

  13. 3000 Series

    272  Pages

  14. MTS8

    23  Pages

  15. CXS-A

    60  Pages

  16. CXSL

    60  Pages

  17. MXQR

    36  Pages

  18. NC(D)Q2-Z

    252  Pages

  19. LEY series

    88  Pages

  20. MXH series

    18  Pages

  21. KQ2

    214  Pages

  22. MXQ series

    198  Pages

  23. Fieldbus System

    92  Pages

  24. CQ2 series

    25  Pages

  25. ISG

    10  Pages

  26. ISE3

    8  Pages

  27. ISE2

    7  Pages

  28. ISE1

    5  Pages

  29. ISA

    59  Pages

  30. IS3000

    2  Pages

  31. IS10/10M/10E

    4  Pages

  32. PSE series

    44  Pages

  33. ISE70/75/75H

    10  Pages

  34. ISE80

    17  Pages

  35. ISE40A

    29  Pages

  36. HED series

    16  Pages

  37. HEC series

    32  Pages

  38. HEB series

    9  Pages

  39. HRG series

    85  Pages

  40. HRZ series

    52  Pages

  41. HRW series

    28  Pages

  42. LQ series

    35  Pages

  43. PA series

    37  Pages

  44. LER series

    62  Pages

  45. LEJ series

    58  Pages

  46. LAT3 series

    24  Pages

  47. LEH series

    103  Pages

  48. CQS series

    59  Pages

  49. CH series

    175  Pages

  50. ARX series

    12  Pages

  51. HRS series

    47  Pages

  52. LES

    59  Pages

  53. MHS

    74  Pages

  54. MHY

    27  Pages

  55. MHC

    27  Pages

  56. MHR

    30  Pages

  57. MHZ series

    78  Pages

  58. MSQ

    37  Pages

  59. MGP

    127  Pages

  60. MXS

    38  Pages

  61. NRB

    10  Pages

  62. MXW

    22  Pages

  63. MHT

    11  Pages

  64. MY3

    54  Pages

  65. CQM

    15  Pages

  66. NCA1

    63  Pages

  67. CM2

    152  Pages

  68. NCM

    91  Pages

  69. NCG

    96  Pages

  70. NCRA1

    5  Pages

  71. CS2

    32  Pages

  72. T/TIA

    1  Page

  73. KR

    7  Pages

  74. KF

    16  Pages

  75. KQ

    80  Pages

  76. AFF

    80  Pages

  77. AMG

    80  Pages

  78. IDF

    16  Pages

  79. HAA

    3  Pages

  80. ZFA

    14  Pages

  81. ZA

    13  Pages

  82. MHF

    32  Pages

  83. CRB

    44  Pages

  84. D

    117  Pages

  85. RB

    23  Pages

  86. CEP

    44  Pages

  87. rsq

    30  Pages

  88. CLK

    51  Pages

  89. MK

    20  Pages

  90. CLJ

    65  Pages

  91. MGJ

    7  Pages

  92. ZSE30A

    17  Pages

  93. IDFB*E

    89  Pages

  94. ISE10

    16  Pages

  95. ITV1000/2000

    50  Pages

  96. AW

    27  Pages

  97. NVFM200

    12  Pages

  98. NVM100

    32  Pages

  99. LLA*A

    36  Pages

  100. VX3*

    41  Pages

  101. SY3000

    158  Pages

  102. CH(D)2

    175  Pages

  103. M(D)SUB

    31  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.