video corpo cad

AC Series - Modular F.R.L. Units
70Pages

{{requestButtons}}

Catalog excerpts

AC Series - Modular F.R.L. Units - 1

Modular F.R.L. Units RoHS Modular Design with Uniform Body Style Better visibility & environmental resistance 2-layer construction The bowl is covered with a transparent bowl guard! * Body size 30 or more ¡The inside is visible from 360°. ¡ he bowl is completely T protected from the environment. Safety improved Transparent bowl guard Material: Polycarbonate Inner bowl Material: Polycarbonate

Open the catalog to page 1
AC Series - Modular F.R.L. Units - 2

Modular F.R.L. Units AC Series Transparent bowl guard M Better environmental resistance: Transparent bowl guard can protect the inner bowl! Windows on the bowl guard have been removed and the inner bowl is instead covered with a polycarbonate transparent bowl guard. Now, even if the environment changes and the bowl is exposed to corrosive chemical or oil splash, the foreign matter will not stick directly to the pressurized bowl. This can reduce risk of bowl breakage. Transparent bowl guard Previous model Cracks may occur in a portion where the internal pressure is applied. Inner bowl...

Open the catalog to page 2
AC Series - Modular F.R.L. Units - 3

Modular F.R.L. Units AC Series Selection of pressure gauges Square embedded type pressure gauge Round type pressure gauge Digital pressure switch Open/close type gauge cover q pen the O gauge cover. w djust the indicator to a A specified position. e lose the gauge cover. C Open the gauge cover in the direction of the arrow with fingertips. Adjust the indicator using a flat blade screwdriver. Close the gauge cover in the direction of the arrow and push it in until it clicks in place. Easy to handle Easy to hold when unlocked Finger grip Pressure regulation while unlocked Interchangeability...

Open the catalog to page 3
AC Series - Modular F.R.L. Units - 4

Modular F.R.L. Units AC Series Filter Regulator © Lubricator

Open the catalog to page 4
AC Series - Modular F.R.L. Units - 5

Modular F.R.L. Units AC Series Mist Separator Micro Mist Separator p. 30 ] Port size IT Interchangeable with existing model • New spacer can be connected to the existing AF-A, AR-B, AL-A, AW-B series. • Existing spacer can be connected to the new AF-D, AR(K)-D, AL-D, AW(K)-D series.

Open the catalog to page 5
AC Series - Modular F.R.L. Units - 6

Air Filter + Regulator + Lubricator TT • Option/Semi-standard: Select one each for a to i. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30-F03DE1-16NR-D

Open the catalog to page 6
AC Series - Modular F.R.L. Units - 7

Body size *1 Drain guide is NPT1/8 (applicable to the AC20-D) and NPT1/4 (applicable to the AC30-D to AC40-D). The auto drain port comes with a 03/8" One-touch fitting (applicable to the AC30-D to AC40-D). *2 Drain guide is G1/8 (applicable to the AC20-D) and G1/4 (applicable to the AC30-D to AC40-D). *3 Options G and M are not assembled and supplied loose at the time of shipment. *4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. *5 If the...

Open the catalog to page 7
AC Series - Modular F.R.L. Units - 8

AC20-D to AC40-D Series Inlet pressure of 0.1 MPa Inlet pressure of 0.7 MPa Flow Rate Characteristics (Representative values) AC20-D Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics (Representative values) Inlet pressure of 0.7 MPa, Outlet pressure of 0.2 MPa, Flow rate 20 L/min (ANR)

Open the catalog to page 8
AC Series - Modular F.R.L. Units - 9

r — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — t Be sure to read this before handling the products. Refer to the back cover for safety instructions. For F.R.L. units I precautions, refer to the “Handling Precautions for SMC Products” and the “Operation Manual”, https://www.smcworld.com 1. Use an air filter with 5 pm or less filtration rating on the inlet side of the valve to avoid any damage to the seat caused by dust when mounting a pressure relief 3-port valve on the inlet side. 1. When the bowl is installed on the air filter, filter...

Open the catalog to page 9
AC Series - Modular F.R.L. Units - 10

P2 (Pressure gauge port size) (Pressure gauge port size) (Pressure gauge port size)

Open the catalog to page 10
AC Series - Modular F.R.L. Units - 12

Filter Regulator + Lubricator • Option/Semi-standard: Select one each for a to i. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30A-F03DE1-16NR-D

Open the catalog to page 12
AC Series - Modular F.R.L. Units - 13

*1 Drain guide is NPT1/8 (applicable to the AC20A-D) and NPT1/4 (applicable to the AC30A-D to AC40A-D). The auto drain port comes with a 03/8" One-touch fitting (applicable to the AC30A-D to AC40A-D). *2 Drain guide is G1/8 (applicable to the AC20A-D) and G1/4 (applicable to the AC30A-D to AC40A-D). *3 Options G and M are not assembled and supplied loose at the time of shipment. *4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. *5 If the...

Open the catalog to page 13
AC Series - Modular F.R.L. Units - 14

P2 (Pressure gauge port size) (Pressure gauge port size) (Pressure gauge port size)

Open the catalog to page 14
AC Series - Modular F.R.L. Units - 16

AC130B 03DE 6 © © © • Option/Semi-standard: Select one each for a to h. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30B-F03DE1-16NR-D

Open the catalog to page 16
AC Series - Modular F.R.L. Units - 17

*1 Drain guide is NPT1/8 (applicable to the AC20B-D) and NPT1/4 (applicable to the AC30B-D to AC40B-D). The auto drain port comes with a 03/8" One-touch fitting (applicable to the AC30B-D to AC40B-D). *2 Drain guide is G1/8 (applicable to the AC20B-D) and G1/4 (applicable to the AC30B-D to AC40B-D). *3 Options G and M are not assembled and supplied loose at the time of shipment. *4 When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl. Releasing the residual condensate before ending operations for the day is recommended. *5 If the...

Open the catalog to page 17
AC Series - Modular F.R.L. Units - 18

(Pressure gauge port size) (Pressure gauge port size) (Pressure gauge port size)

Open the catalog to page 18
AC Series - Modular F.R.L. Units - 20

Air Filter + Mist Separator + Regulator • Option/Semi-standard: Select one each for a to h. • Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AC30C-F03DE1-16NR-D

Open the catalog to page 20

All SMC Corporation of America catalogs and technical brochures

  1. IFW5 series

    5 Pages

  2. ASG

    4 Pages

  3. IDG

    49 Pages

  4. CXSJ_M

    2 Pages

  5. JLV20/30

    8 Pages

  6. Series NCQ2/CQ2

    252 Pages

  7. KQG2

    18 Pages

  8. IDF*E

    48 Pages

  9. SYJ300

    60 Pages

  10. 3000 Series

    272 Pages

  11. MTS8

    23 Pages

  12. CXS-A

    60 Pages

  13. CXSL

    60 Pages

  14. MXQR

    36 Pages

  15. NC(D)Q2-Z

    252 Pages

  16. LEY series

    88 Pages

  17. MXH series

    18 Pages

  18. KQ2

    214 Pages

  19. MXQ series

    198 Pages

  20. CQ2 series

    25 Pages

  21. ISG

    10 Pages

  22. ISE3

    8 Pages

  23. ISE2

    7 Pages

  24. ISE1

    5 Pages

  25. ISA

    59 Pages

  26. IS3000

    2 Pages

  27. IS10/10M/10E

    4 Pages

  28. PSE series

    44 Pages

  29. ISE70/75/75H

    10 Pages

  30. ISE80

    17 Pages

  31. ISE40A

    29 Pages

  32. HED series

    16 Pages

  33. HEC series

    32 Pages

  34. HEB series

    9 Pages

  35. HRG series

    85 Pages

  36. HRZ series

    52 Pages

  37. HRW series

    28 Pages

  38. LQ series

    35 Pages

  39. PA series

    37 Pages

  40. LER series

    62 Pages

  41. LEJ series

    58 Pages

  42. LAT3 series

    24 Pages

  43. LEH series

    103 Pages

  44. CQS series

    59 Pages

  45. CH series

    175 Pages

  46. ARX series

    12 Pages

  47. HRS series

    47 Pages

  48. LES

    59 Pages

  49. MHS

    74 Pages

  50. MHY

    27 Pages

  51. MHC

    27 Pages

  52. MHR

    30 Pages

  53. MHZ series

    78 Pages

  54. MSQ

    37 Pages

  55. MGP

    127 Pages

  56. MXS

    38 Pages

  57. NRB

    10 Pages

  58. MXW

    22 Pages

  59. MHT

    11 Pages

  60. MY3

    54 Pages

  61. CQM

    15 Pages

  62. NCA1

    63 Pages

  63. CM2

    152 Pages

  64. NCM

    91 Pages

  65. NCG

    96 Pages

  66. NCRA1

    5 Pages

  67. CS2

    32 Pages

  68. T/TIA

    1 Pages

  69. KR

    7 Pages

  70. KF

    16 Pages

  71. KQ

    80 Pages

  72. AFF

    80 Pages

  73. AMG

    80 Pages

  74. IDF

    16 Pages

  75. HAA

    3 Pages

  76. ZFA

    14 Pages

  77. ZA

    13 Pages

  78. MHF

    32 Pages

  79. CRB

    44 Pages

  80. D

    117 Pages

  81. RB

    23 Pages

  82. CEP

    44 Pages

  83. rsq

    30 Pages

  84. CLK

    51 Pages

  85. MK

    20 Pages

  86. CLJ

    65 Pages

  87. MGJ

    7 Pages

  88. ZSE30A

    17 Pages

  89. IDFB*E

    89 Pages

  90. ISE10

    16 Pages

  91. ITV1000/2000

    50 Pages

  92. AW

    27 Pages

  93. NVFM200

    12 Pages

  94. NVM100

    32 Pages

  95. LLA*A

    36 Pages

  96. VX3*

    41 Pages

  97. SY3000

    158 Pages

  98. CH(D)2

    175 Pages

  99. LEHZ

    82 Pages

  100. M(D)SUB

    31 Pages

  101. CXSJ

    58 Pages

  102. CY3B

    39 Pages

  103. C(D)Q2W-Z

    208 Pages

Archived catalogs

  1. ZSE1 series

    12 Pages

  2. VV061 series

    11 Pages

  3. SX series

    138 Pages

  4. ACG series

    25 Pages

  5. Shock Absorber

    16 Pages

  6. Silencer

    4 Pages