Catalog excerpts

PJB single-blade air dampers-1

CIRCULAR SINGLE-BLADE DAMPER Characteristics: A circular single-blade damper used for airflow control or closing. Controlled manually or by an electric actuator. Single-blade dampers are used for airflow control or closing in circular ventilation ducts. Operating temperature: -20 °C to +90 °C, (+50 °C for the actuator version). Damper: galvanised sheet steel SO or sheet stainless steel (1.4301) SN Mechanism elements: moulded from galvanised steel or stainless steel. Normally - no flanges, adjusted for connection with SPIRO ducts. Upon special request, we can manufacture the following dampers: • Adjusted to other types of connection in a version including external insulation • In a version with a rubber gasket at the connection • In an airtight damper version (a gasket on the baffle). The device holds hygiene certificate no. HK/B/1514/01/2012. Manufacturing versions • PJB - Control damper (a baffle without a gasket), • PJB-U - Shut-off damper (a baffle with a gasket). • T1 - Damper with an actuator, • T2 - Damper with a manual mechanism • T3 - Damper with an extended axle (for the actuator installation) Table 1. Types of actuators and the net surface area for the PJB damper in a fully open position. Note: the parameters given in the table apply to the version -U \(a baffle with a gasket) Table 2. Type of the actuator. The given actuator types can be used in several variants differing in communication and supply voltage. Circular single-blade damper

 Open the catalog to page 1
PJB single-blade air dampers-2

Technical Data Chart 1. Pressure loss for the PJB damper (in a fully open position). Chart 3. Air leaks through the PJB-U damper baffle (in a fully closed position). Circular single-blade damper Chart 2. Pressure loss for the PJB damper (in a fully open position). Chart 4. Air leaks through the PJB-U damper housing (in a fully closed position).

 Open the catalog to page 2
PJB single-blade air dampers-3

none - A baffle without a gasket U - A baffle with a gasket CX - Housing: C, baffle: none (a baffle without a gasket) C4 - Housing: C, baffle: 4 (a baffle with a gasket) Circular single-blade damper

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.