Product Overview
The FLOWEVO Infrared Gas Sensor for Sulfuryl Fluoride (SO2F2) is a pre-calibrated, compact device designed for applications such as fumigation monitoring, pest control, and process control. It features a 3/5 mm gas line connector and operates on a 3.3–6 V DC supply voltage. The sensor communicates via Modbus ASCII or RTU and indicates status through an LED.
Specifications
  • Measurement Principle: Non-Dispersive Infra-Red (NDIR), dual wavelength
  • Measurement Range: 0 ... 4 Vol.-% Full Scale (FS)
  • Flow Rate: 0.1 ... 1.0 l/min
  • Mounting Dimensions: 70 mm x 60 mm x 40 mm
  • Warm-up Time: Less than 2 minutes for start-up, less than 30 minutes for full specification
Measuring Response
  • Digital Resolution: 0.001 Vol.-%
  • Response Time: Standard t90 ≤ 12.6 s, Fast t90 ≤ 1.2 s
  • Detection Limit: ≤ 0.004 Vol.-% (Standard), ≤ 0.008 Vol.-% (Fast)
  • Repeatability: ≤ ± 0.02 Vol.-%
  • Linearity Error: ≤ ± 0.04 Vol.-%
  • Long Term Stability: Zero ≤ ± 0.025 Vol.-% over 1000 hours, Span ≤ ± 0.045 Vol.-% over 1000 hours
Environmental and Electrical Parameters
  • Operating Temperature: 0 to +50 °C
  • Storage Temperature: -20 to +60 °C
  • Air Pressure: 800 to 1150 hPa
  • Humidity: 0 to 95% relative humidity (non-condensing)
  • Supply Voltage: 3.3 V to 6.0 VDC
  • Power Consumption: Average < 800 mW
Additional Information
The sensor requires a stable gas dew point of less than +5°C and a clean, particle-free sample gas. Calibration is recommended at first initiation and periodically thereafter. The device is made in Germany and all specifications are subject to change without notice. For further details, visit the smartGAS website or contact their sales team.
See more

Catalog excerpts

Sulfuryl Flouride SO2F2 4 Vol.-%-1

FLOWEVO Infrared gas Sensor Sulfuryl Flouride SO2F2 4 Vol.-% smartGAS item number: F3-412406-05000 Pre calibrated Compact Design 3/5 mm gas line connector 3.3–6 V DC supply voltage Modbus ASCII or RTU Status indicated by LED Low drift Application examples Fumigation monitoring Pest control Process control Available equipment Gas cooler Particle filter Gas pump Calibration Software Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical Installation Data communication Gas pre-treatment

 Open the catalog to page 1
Sulfuryl Flouride SO2F2 4 Vol.-%-2

FLOWEVO I Sulfuryl Flouride SO2F2 I F3-412406-05000 General features Measurement principle: Non-Dispersive Infra-Red (NDIR), dual wavelength Measurement range: by flow (nearly atmospheric pressure) Flow rate: Mounting dimensions: Warm-up time: < 2 minutes (start-up time) < 30 minutes (full specification) Measuring response* Digital resolution: Linearity error (straight line deviation): Long term stability (zero): Long term stability (span): Influence of T, P, flow rate, other* Temp. dependence (zero): Temp. dependence (span): Pressure dependence: Flow rate dependence: Cross sensitivity (zero)...

 Open the catalog to page 2

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.