Product Overview: The FLOWEVO Infrared Gas Sensor by smartGAS Mikrosensorik GmbH is designed for detecting Sulfuryl Fluoride (SO2F2) at concentrations up to 100 ppm. It features a pre-calibrated, compact design with a 3/5 mm gas line connector and operates on a 3.3–6 V DC supply voltage. The sensor supports Modbus ASCII or RTU communication and includes an LED status indicator.
Applications: The sensor is suitable for fumigation monitoring, leak detection, and occupational health and safety monitoring. Additional equipment available includes a gas cooler, particle filter, gas pump, calibration software, and mounting equipment.
Technical Specifications: The sensor uses a Non-Dispersive Infra-Red (NDIR) dual wavelength measurement principle. It has a measurement range of 0 to 100 ppm with a flow rate of 0.1 to 1.0 l/min. The sensor dimensions are 336 mm x 30 mm x 50 mm, with a warm-up time of less than 2 minutes for start-up and less than 30 minutes for full specification.
Performance: The digital resolution is 0.01 ppm, with a response time of ≤ 13.2 seconds for standard and ≤ 1.1 seconds for fast response at 0.7 l/min. The detection limit is ≤ 2 ppm for standard and ≤ 5 ppm for fast response. Repeatability and linearity error are both ≤ ± 1 ppm. Long-term stability is ≤ ± 4 ppm (zero) and ≤ ± 5 ppm (span) over 1000 hours.
Environmental and Electrical Parameters: The sensor operates within a temperature range of 0 to +50 °C and can be stored between -20 to +60 °C. It functions under air pressure from 800 to 1150 hPa and relative humidity from 0 to 95% (non-condensing). The supply current peaks at < 400 mA at 3.3 V and < 240 mA at 5.0 V, with an average power consumption of < 800 mW.
Additional Information: The sensor requires a stable gas dew point of < +5°C and a clean, particle-free sample gas. Calibration is performed via software for zero and span adjustments. The document notes that specifications are subject to change and recommends recalibration depending on application and ambient conditions.
See more

Catalog excerpts

Sulfuryl Flouride SO2F2 100 ppm-1

FLOWEVO Infrared gas Sensor Sulfuryl Flouride SO2F2 100 ppm smartGAS item number: F3-412104-05000 Pre calibrated Compact Design 3/5 mm gas line connector 3.3–6 V DC supply voltage Modbus ASCII or RTU Status indicated by LED Low drift Application examples Fumigation monitoring Leak detection Occupational health and safety monitoring Available equipment Gas cooler Particle filter Gas pump Calibration Software Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical Installation Data communication Gas pre-treatment

 Open the catalog to page 1
Sulfuryl Flouride SO2F2 100 ppm-2

FLOWEVO I Sulfuryl Flouride SO2F2 I F3-412104-05000 General features Measurement principle: Non-Dispersive Infra-Red (NDIR), dual wavelength Measurement range: by flow (nearly atmospheric pressure) Flow rate: Mounting dimensions: Warm-up time: < 2 minutes (start-up time) < 30 minutes (full specification) Measuring response* Digital resolution: Linearity error (straight line deviation): Long term stability (zero): Long term stability (span): Influence of T, P, flow rate, other* Temp. dependence (zero): Temp. dependence (span): Pressure dependence: Flow rate dependence: Cross sensitivity (zero)...

 Open the catalog to page 2

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.