video corpo

PA-032105-00000

PA-032105-00000

PA-032105-00000

Product catalog summary
Overview: The document provides technical specifications and features of the PAS Photoacoustic Gas Sensor for Ethylene (C2H4) with a measurement range of up to 1000 ppm. The sensor is designed for continuous operation and can be controlled via a connected PLC or operate autonomously.
Key Features:
  • Self-controlled or partially controlled operation.
  • Compact design with zero-calibration capability.
  • Continuous data access via UART data stream.
  • Automatic water vapor cross-sensitivity compensation.
  • 24/7 operational design.
Applications: The sensor is suitable for gas analysis, biogas applications, environmental monitoring, process control, and emission monitoring.
Technical Specifications:
  • Measurement Principle: Photoacoustic.
  • Measurement Range: 0 to 1000 ppm Full Scale.
  • Flow Rate: 0.1 to 2.0 l/min.
  • Warm-up Time: ≤ 10 minutes.
  • Digital Resolution: 0.1 ppm.
  • Detection Limit: ≤ 5 ppm.
  • Repeatability: ≤ 1% of measured value plus ± 1.5 ppm.
  • Long Term Stability: Zero ≤ ± 1.5 ppm over 24 hours; Span ≤ 1% of value ± 3 ppm over 24 hours.
Electrical Parameters:
  • Power Supply: 12 Volts DC ± 1%.
  • Power Consumption: 45 Watts during heat-up, 15 Watts during operation.
  • Communication: TTL-UART and digital I/O’s.
  • Calibration: Zero-calibration by external command or automatic.
Climatic Conditions:
  • Operating Temperature: +10°C to +40°C.
  • Storage Temperature: +10°C to +40°C.
  • Air Pressure: 800 to 1150 hPa.
  • Ambient Humidity: 0 to 95% relative humidity (non-condensing).
Additional Information: The document notes that specifications are subject to change and recommends recalibration depending on application and ambient conditions. It also emphasizes the need for dry air or nitrogen purging of the housing to prevent condensation.
See more

Catalog excerpts

PA-032105-00000-1

PAS Photoacoustic gas Sensor Ethylene C2H4 1000 ppm smartGAS item number: PA-032105-00000 Self-controlledor partiallycontrol via a connected PLC Compact Design Zero-calibration by external command or automatic Measured values continuously accessible via UART data stream Status indicated by LED Automatic compensation of the water vapor cross-sensitivity Designed for 24/7 operation Application examples Gas analysis Biogas application Environmental monitoring Process control Emission monitoring Available equipment Gas cooler Particle filter Gas pump Mounting equipment Galvanically isolated output smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical Installation Data communication Gas pre-treatment

 Open the catalog to page 1
PA-032105-00000-2

PAS I Ethylene C2H4 I PA-032105-00000 General features Measurement principle: Measurement range: by flow (nearly atmospheric pressure) Flow rate: Mounting dimensions: Warm-up time: Measuring response* Digital resolution: ≤ 1% of measured value plus ± 1.5 ppm Long term stability (zero): Long term stability (span): ≤ 1% of value ± 3 ppm over 24 h period Electrical parameters Power Supply Power consumption: 10 minute heat up approx.45 Watts / Operation approx. 15 Watts Zero-calibration by external command or automatic Climatic conditions Operating temperature: Storage temperature: 800 – 1150 hPa...