Overview: The SILAREX NDIR Multi-Gas Sensor by smartGAS Mikrosensorik GmbH is designed for Continuous Emission Monitoring Systems (CEMS), capable of measuring CO2 up to 20 Vol.-% and CO up to 1000 ppm. It features dual active measurement channels, is pre-calibrated, and includes on-board cross and pressure compensation. Communication is facilitated via Modbus ASCII/RTU.
Specifications:
  • Measurement Principle: Non-Dispersive Infra-Red (NDIR), dual wavelength.
  • Measurement Range: CO2: 0 to 20 Vol.-%, CO: 0 to 1000 ppm.
  • Flow Rate: 0.1 to 1.0 l/min.
  • Response Time: Fast: < 4s, Medium: < 8s, Slow: < 60s at 0.7 l/min.
  • Digital Resolution: CO2: 0.01 Vol.-%, CO: 1 ppm.
  • Repeatability: CO2: ≤ ± 0.06 Vol.-%, CO: ≤ ± 6 ppm.
  • Linearity Error: CO2: ≤ ± 0.1 Vol.-%, CO: ≤ ± 10 ppm.
  • Long Term Stability: Zero: CO2: ≤ ± 0.01 Vol.-%, CO: ≤ ± 5 ppm after 1000 hours.
Environmental Conditions:
  • Operating Temperature: +10 to +40 °C with thermal isolation.
  • Storage Temperature: -20 to +60 °C.
  • Humidity: 0 to 95% relative humidity, non-condensing.
  • Air Pressure: 800 to 1150 hPa.
Electrical Inputs and Outputs:
  • Supply Voltage: 24 V DC ± 10%.
  • Power Consumption: < 6 W with heater on, < 1 W at stabilized temperature.
  • Inrush Current: < 400 mA.
  • Output Signal: Modbus ASCII/RTU via RS485.
Accessories and Options: The sensor can be equipped with insulation housing, gas cooler, particle filter, gas pump, and mounting equipment. It is available in 2-channel and 3-channel designs.
Recommendations: Initial and periodic recalibration is recommended depending on application and ambient conditions. For more information, visit the smartGAS website or contact their sales team.
See more

Catalog excerpts

NDIR Multi-Gas Sensor for CEMS CO2 20 Vol.-% // CO 1000 ppm-1

CEMS Dual Gas NDIR sensor 2 active measurement channels Ready to use calibrated On board cross compensation On board pressure compensation Modbus ASCII/RTU, autobaud, autoframe Status indicated by LED NDIR Multi-Gas Sensor for CEMS CO2 20 Vol.-% // CO 1000 ppm smartGAS item number: SX-200002-00000 Application Examples Emission monitoring CEMS Biogas Process measurement Accessories Insulation housing Gas cooler Particle filter Gas pump Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical Installation Data communication Gas pre-treatment

 Open the catalog to page 1
NDIR Multi-Gas Sensor for CEMS CO2 20 Vol.-% // CO 1000 ppm-2

SILAREX I CO2 // CO I SX-200002-00000 General features Measurement principle: Non Dispersive Infra-Red (NDIR), dual wavelength Target gas: Measurement range: by flow (nearly atmospheric pressure) Flow rate: Mounting dimensions: Warm-up time: < 2 minutes (start up time) < 30 minutes (full specification) Measuring response* Response time (t90) @ 0.7 l / min: < 4 s (fast), < 8 s (medium), < 60 s (slow) Digital resolution: Detection limit (3 σ) max.: in fast / medium / slow mode: Repeatability: Linearity error (straight line deviation): Long term stability (zero): after 1000 h operating time Long...

 Open the catalog to page 2
NDIR Multi-Gas Sensor for CEMS CO2 20 Vol.-% // CO 1000 ppm-3

Climatic conditions Sensor heating temperature Operating ambient temperature: appr. + 10 … + 40 °C (thermal isolation required) Storage temperature: Ambient humidity: Typical values related to 1013 hPa, Ta = 22 °C, flow = 0.7 l / min for dry (not condensing) and clean sample gas. Stated values exclude calibration gas tolerance. All rights reserved. Any logos and/or product names are trademarks of smartGAS. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of smartGAS is strictly prohibited. All specifications...

 Open the catalog to page 3

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.