video corpo

Methane CH4 5 Vol.-%

Methane CH4 5 Vol.-%

Methane CH4 5 Vol.-%

Product catalog summary
Product Overview
The FLOWEVO Infrared Gas Sensor for Methane (CH4) by smartGAS Mikrosensorik GmbH is a pre-calibrated, compact device designed for gas analysis, biogas applications, and environmental monitoring. It features a 3/5 mm gas line connector and operates on a 3.3–6 V DC supply voltage. The sensor supports Modbus ASCII or RTU communication and includes an LED status indicator.

Specifications
  • Measurement Principle: Non-Dispersive Infra-Red (NDIR), dual wavelength
  • Measurement Range: 0 to 5 Vol.-% Full Scale (FS)
  • Flow Rate: 0.1 to 1.0 l/min
  • Dimensions: 156 mm x 30 mm x 50 mm
  • Warm-up Time: Less than 2 minutes for start-up, less than 30 minutes for full specification

Measuring Response
  • Digital Resolution: 0.001 Vol.-%
  • Response Time: t90 ≤ 11.6 s (standard), ≤ 0.9 s (fast)
  • Detection Limit: ≤ 0.03 Vol.-% (standard), ≤ 0.07 Vol.-% (fast)
  • Repeatability: ≤ ± 0.05 Vol.-%
  • Linearity Error: ≤ ± 0.05 Vol.-%
  • Long Term Stability: Zero ≤ ± 0.044 Vol.-% over 1000 hours, Span ≤ ± 0.315 Vol.-% over 1000 hours

Environmental and Electrical Parameters
  • Operating Temperature: 0 to +50 °C
  • Storage Temperature: -20 to +60 °C
  • Air Pressure: 800 to 1150 hPa
  • Humidity: 0 to 95% relative humidity (non-condensing)
  • Supply Voltage: 3.3 V to 6.0 VDC
  • Power Consumption: Average < 800 mW

Additional Information
The sensor requires a stable gas dew point of less than +5°C and a clean, particle-free sample gas. Calibration is recommended at first initiation and periodically thereafter. The device's specifications are subject to change without notice, and users are advised to consult smartGAS for specific applications and recalibration needs.
See more

Catalog excerpts

Methane CH4 5 Vol.-%-1

FLOWEVO Infrared gas Sensor Methane CH4 5 Vol.-% smartGAS item number: F3-042506-05000 Pre calibrated Compact Design 3/5 mm gas line connector 3.3–6 V DC supply voltage Modbus ASCII or RTU Status indicated by LED Low drift Application examples Gas analysis Biogas application Environmental monitoring Available equipment Gas cooler Particle filter Gas pump Calibration Software Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical Installation Data communication Gas pre-treatment

 Open the catalog to page 1
Methane CH4 5 Vol.-%-2

FLOWEVO I Methane CH4 I F3-042506-05000 General features Measurement principle: Non-Dispersive Infra-Red (NDIR), dual wavelength Measurement range: by flow (nearly atmospheric pressure) Flow rate: Mounting dimensions: Warm-up time: < 2 minutes (start-up time) < 30 minutes (full specification) Measuring response* Digital resolution: Linearity error (straight line deviation): Long term stability (zero): Long term stability (span): Influence of T, P, flow rate, other* Temp. dependence (zero): Temp. dependence (span): Pressure dependence: Flow rate dependence: Cross sensitivity (zero) other gases:...

 Open the catalog to page 2

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.