Product Overview
The FLOWEVO Infrared Gas Sensor is designed for detecting Ethylene (C2H4) with a measurement range of 0 to 2000 ppm. It features a pre-calibrated, compact design with a 3/5 mm gas line connector and operates on a 3.3–6 V DC supply voltage. The sensor supports Modbus ASCII or RTU communication and indicates status via an LED. It is noted for its low drift and is suitable for applications such as process control, fruit ripening, degreening, and analysis.
Specifications
  • Measurement Principle: Non-Dispersive Infra-Red (NDIR), dual wavelength
  • Flow Rate: 0.1 to 1.0 l/min
  • Mounting Dimensions: 156 mm x 30 mm x 50 mm
  • Warm-up Time: Less than 2 minutes for start-up, less than 30 minutes for full specification
Measuring Response
  • Digital Resolution: 1 ppm
  • Response Time: t90 ≤ 11.6 s, ton ≤ 15.9 s
  • Detection Limit: ≤ 20 ppm
  • Repeatability: ≤ ± 20 ppm
  • Linearity Error: ≤ ± 30 ppm
  • Long Term Stability: Zero ≤ ± 250 ppm, Span ≤ ± 300 ppm over 240 hours
Environmental and Electrical Parameters
  • Operating Temperature: 0 to +50 °C
  • Storage Temperature: -20 to +60 °C
  • Air Pressure: 800 to 1150 hPa
  • Humidity: 0 to 95% relative humidity (non-condensing)
  • Supply Voltage: 3.3 V to 6.0 VDC
  • Power Consumption: Average < 800 mW
Additional Information
The sensor requires a stable gas dew point of less than +5°C and a clean, particle-free sample gas. Calibration is recommended at first initiation and periodically thereafter. The sensor's performance may vary based on application, target gas, and measurement range. For further details, visit the smartGAS website or contact their sales team.
See more

Catalog excerpts

Ethylene C2H4-1

FLOWEVO Infrared gas Sensor Ethylene C2H4 2000 ppm smartGAS item number: F3-032205-05000 Pre calibrated Compact Design 3/5 mm gas line connector 3.3–6 V DC supply voltage Modbus ASCII or RTU Status indicated by LED Low drift Application examples Process control Fruit ripening Degreening Analysis Available equipment Gas cooler Particle filter Gas pump Calibration Software Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical Installation Data communication Gas pre-treatment

 Open the catalog to page 1
Ethylene C2H4-2

FLOWEVO I Ethylene C2H4 I F3-032205-05000 General features Measurement principle: Non-Dispersive Infra-Red (NDIR), dual wavelength Measurement range: by flow (nearly atmospheric pressure) Flow rate: Mounting dimensions: Warm-up time: < 2 minutes (start-up time) < 30 minutes (full specification) Measuring response* Digital resolution: Linearity error (straight line deviation): Long term stability (zero): Long term stability (span): Influence of T, P, flow rate, other* Temp. dependence (zero): Temp. dependence (span): Pressure dependence: Flow rate dependence: Cross sensitivity (zero) other gases:...

 Open the catalog to page 2

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. PAS

    4  Pages

  2. SILAREX

    4  Pages

  3. FLOW EVO

    2  Pages

  4. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.