Product catalog summary
Product Overview
The BASICEVO Infrared Gas Sensor for Chlorodifluoromethane R407f is designed for detecting gas concentrations up to 2000 ppm. It features pre-calibration, low drift, and gas entry by diffusion. The sensor operates on a 3.3 - 6 V DC supply voltage and supports Modbus ASCII or RTU communication protocols. Status is indicated via LED.

Applications
This sensor is suitable for use in hotel air conditioning, food storage rooms, industrial refrigeration, food transport, and research.

Available Equipment
Accessories include a connect interface, wall mount enclosure, calibration software, and mounting equipment. It is also available as a complete transmitter.

General Features
The sensor uses a Non-Dispersive Infra-Red (NDIR) dual wavelength measurement principle. It has a measurement range of 0 to 2000 ppm and operates by gas diffusion at atmospheric pressure. The dimensions are 62 mm x 37 mm x 30 mm, with a warm-up time of less than 30 minutes for full specification.

Measuring Response
The response time is approximately 60 seconds with a digital resolution of 1 ppm. The detection limit is ≤ 10 ppm, with repeatability and linearity error both ≤ ± 10 ppm. Long-term stability is ≤ ± 30 ppm for zero and ≤ ± 40 ppm for span over a 12-month period.

Influence of Temperature, Pressure, and Flow Rate
Temperature dependence is ≤ ± 2 ppm per °C for zero and ≤ ± 4 ppm per °C for span. Pressure dependence is +0.100% of the actual reading per hPa.

Electrical Parameters
The sensor requires a supply voltage of 3.3 V to 6.0 VDC, with a peak supply current of < 400 mA at 3.3 V and < 240 mA at 5.0 V. Inrush current is < 450 mA, and average power consumption is < 800 mW. It outputs a digital signal via Modbus ASCII/RTU.

Climatic Conditions
Operating temperature ranges from -20 to +40 °C, with storage temperatures from -20 to +60 °C. It can operate in air pressure conditions of 800 to 1150 hPa and ambient humidity of 0 to 95% relative humidity (non-condensing).

Additional Information
All specifications are subject to change without notice. Recalibration is recommended at first initiation and periodically thereafter. For more information, visit the smartGAS website or contact their sales team.
See more

Catalog excerpts

B3-822205-03000-1

BASICEVO Infrared gas Sensor Chlorodifluoromethane R407f 2000 ppm smartGAS item number: B3-822205-03000 Pre calibrated Low drift Gas entry by diffusion 3.3 - 6 V DC supply voltage Modbus ASCII or RTU Status indication by LED Application examples Hotel air conditioning Food storage rooms Industrial Refrigeration Food Transport Research Available equipment Connect Interface Wall mount enclosure Calibration software Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical installation Data communication also, as complete Transmitter

 Open the catalog to page 1
B3-822205-03000-2

BASICEVO I Chlorodifluoromethane R407f I B3-822205-03000 General features Measurement principle: Non Dispersive Infra-Red (NDIR), dual wavelength Measurement range: 0 … 2000 ppm Full Scale (FS) by diffusion (atmospheric pressure) Gas supply: Mounting dimensions: Warm-up time: 62 mm x 37 mm x 30 mm (L x W x H) < 2 minutes (start up time) < 11 minutes (fade in finished) < 30 minutes (full specification) Measuring response* Response time (t90): Digital resolution: Linearity error (straight line deviation): Long term stability (zero): ≤ ± 30 ppm over 12 month period Long term stability (span): ≤...

 Open the catalog to page 2

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.