Product Overview
The BASICEVO Infrared Gas Sensor is designed for detecting Chlorodifluoromethane R22 with a measurement range of 0 to 2000 ppm. It is pre-calibrated, features low drift, and operates with a supply voltage of 3.3 to 6 V DC. The sensor communicates via Modbus ASCII or RTU and includes an LED status indicator.

Applications
This sensor is suitable for use in hotel air conditioning, food storage rooms, industrial refrigeration, food transport, and research.

Available Equipment
Accessories include a connect interface, wall mount enclosure, calibration software, and mounting equipment. It is also available as a complete transmitter.

Technical Specifications
  • Measurement Principle: Non-Dispersive Infra-Red (NDIR), dual wavelength
  • Response Time (t90): Approximately 60 seconds
  • Digital Resolution: 1 ppm
  • Detection Limit: ≤ 10 ppm
  • Repeatability: ≤ ± 20 ppm
  • Linearity Error: ≤ ± 30 ppm
  • Long Term Stability: Zero ≤ ± 30 ppm, Span ≤ ± 40 ppm over 12 months

Environmental and Electrical Parameters
  • Operating Temperature: -20 to +40 °C
  • Storage Temperature: -20 to +60 °C
  • Air Pressure: 800 to 1150 hPa
  • Humidity: 0 to 95% relative humidity (non-condensing)
  • Supply Current: Peak < 400 mA @ 3.3 V, < 240 mA @ 5.0 V
  • Average Power Consumption: < 800 mW

Additional Information
Recalibration is recommended at first initiation and periodically depending on application and ambient conditions. The document notes that specifications are subject to change and advises consulting smartGAS for specific requirements.
See more

Catalog excerpts

B3-702205-03000-1

BASICEVO Infrared gas Sensor Chlorodifluoromethane R22 2000 ppm smartGAS item number: B3-702205-03000 Pre calibrated Low drift Gas entry by diffusion 3.3 - 6 V DC supply voltage Modbus ASCII or RTU Status indication by LED Application examples Hotel air conditioning Food storage rooms Industrial Refrigeration Food Transport Research Available equipment Connect Interface Wall mount enclosure Calibration software Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Available design in support Mechanical installation Data communication also, as complete Transmitter

 Open the catalog to page 1
B3-702205-03000-2

BASICEVO I Chlorodifluoromethane R22 I B3-702205-03000 General features Measurement principle: Non Dispersive Infra-Red (NDIR), dual wavelength Measurement range: 0 … 2000 ppm Full Scale (FS) by diffusion (atmospheric pressure) Gas supply: Mounting dimensions: Warm-up time: 62 mm x 37 mm x 30 mm (L x W x H) < 2 minutes (start up time) < 11 minutes (fade in finished) < 30 minutes (full specification) Measuring response* Response time (t90): Digital resolution: Linearity error (straight line deviation): Long term stability (zero): ≤ ± 30 ppm over 12 month period Long term stability (span): ≤ ±...