video corpo

AX-600000-00000

AX-600000-00000

AX-600000-00000

Product catalog summary
Overview: The ANAREX SF6 Analyzer by smartGAS Mikrosensorik GmbH is a high-performance device designed for detecting SF6 gas leaks in high voltage applications. It features a user-friendly touch screen interface and supports easy sensor calibration. The analyzer is suitable for installation in a 19" rack and can handle multiple gases using various sensor technologies.
Key Features:
  • Measurement Range: 0-50 ppm for SF6 with a detection limit of ≤ 1.15 ppm.
  • Repeatability: ≤ ± 0.5 ppm; Drift: ≤ ± 7 ppm over 240 hours.
  • Display: 5.6” LCD touch screen.
  • Output: Analog (4-20 mA) and digital (RS232).
  • Alarm System: Device status and measurement channel level alarms with relay triggers.
  • Power Requirements: 198-242 V AC, 50/60 Hz.
  • Protection Level: IP42.
  • Weight: 15 kg.
Gas Flow & Environmental Conditions:
  • Gas Inlet Flow: 0.4-0.8 L/min with minimal fluctuation.
  • Operating Temperature: 10°C to 40°C.
  • Humidity: 0-95% RH, non-condensing.
  • Pressure: 76-116 kPa.
Measurement Principles: The analyzer uses NDIR, photoacoustic, paramagnetic, and electrochemical sensors to ensure accurate gas detection and measurement.
Customization Options: The device can be customized for different gases, detection ranges, and software configurations to meet specific application requirements.
Recommendations: Regular recalibration is recommended, especially after initial setup and depending on application and ambient conditions.
Disclaimer: Specifications are subject to change without notice, and the document does not constitute a specification or offer for sale. For more information, visit the smartGAS website or contact their sales team.
See more

Catalog excerpts

AX-600000-00000-1

Multigas analyzer Easy operation via touch screen Easy sensor calibration Best measurement performance For installation in a 19" rack Analog or digital output Photoacoustic sensors NDIR sensors Paramagnetic sensors Technology Electro chemical sensors The ANAREX SF6 analyzer of smartGAS is a high-performance solution for the leakage detection in high voltage application. It convinces with its highly accurate and stable measurement performance as well as its customerfriendly interfacing via touch screen along with a simple sensor calibration. The ANAREX is designed as a multi-gas analyzer and is suitable for installation in a 19" rack. The smartGAS analyzer can also use different technologies to fulfil all kinds of application requirement. The smartGAS Analyzer is equipped with a 5.6" touch screen, that displays the gas concentration as real-time reading. The internal software is designed to control zero, span and third point calibration to ensure a perfect accuracy of the measurement values. Application examples High voltage Measuring principles Infrared NDIR Peripherals Gas cooler Pumps Particle filter Tubes Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Customizing options Measuring gases Detection ranges Design and Software Gas pre treatment

 Open the catalog to page 1
AX-600000-00000-2

General features* Measurement principle: Measurement range: Detection Limits: Basic information Display: Analogue output: 4-20 mA (in operation) 2 mA (Warm-up or alarm) Load resistance: Alarm output: Device status alarm // Measurement channel level alarm Relay will close and isolate if alarm limits are exceeded 1 A Trigger (250 V AC / 2 A, resistive load) Power connection: Rated current: 3A; Size: 5 x 20 mm Protection level: smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu

 Open the catalog to page 2
AX-600000-00000-3

Gas flow & Environment information Gas Inlet flow: (0.4 ~ 0.8) L/min (flow fluctuation ≤ 0.02 L/min) non-condensing Inlet dew point: 5°C ± 0.1°C 99.999 % N2 (NDIR) Clean air, free of sample gas (Photoacoustic) 75 % ~ 110 % of span point Clean air (0 ~ 25 % O2 measurement) Operation temperature: Typical values related to 1013 hPa, Ta = 22 °C, flow = 0.7 l / min for dry (not condensing) and clean sample gas. Stated values exclude calibration gas tolerance. All rights reserved. Any logos and/or product names are trademarks of smartGAS. The reproduction, transfer, distribution or storage of information...

 Open the catalog to page 3

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.