Catalog excerpts
ANAREX Multigas Analyzer AX-212200-00100 Multigas analyzer Easy operation via touch screen Easy sensor calibration Best measurement performance For installation in a 19" rack Analog or digital output Photoacoustic sensors NDIR sensors Paramagnetic sensors Technology Electro chemical sensors The ANAREX gas analyzers of smartGAS are high-performance solutions for various sectors of industrial gas measurement technology. The fields of application range from process measurement technology and emissions to fruit ripening. It convinces with its highly accurate and stable measurement performance as well as its customer-friendly interfacing via touch screen along with a simple sensor calibration. The ANAREX is designed as a multi-gas analyzer and is suitable for installation in a 19" rack. The smartGAS analyzer can also use different technologies to fulfil all kinds of application requirement. The smartGAS Analyzer is equipped with a 5.6" touch screen, that displays the gas concentration as real-time reading. The internal software is designed to control zero, span and third point calibration to ensure a perfect accuracy of the measurement values. Application examples Emission monitoring CEMS Process control Measuring principles Infrared NDIR Peripherals Gas cooler Pumps Particle filter Tubes Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I sales@smartgas.eu I www.smartgas.eu Customizing options Measuring gases Detection ranges Design and Software Gas pre treatment
Open the catalog to page 1General features Measurement principle: Measurement range: Detection Limits: Repeatabiliy Drift: CO2 … NDIR CO … NDIR 0 … 20 Vol.-% (CO2) 0 … 10,000 ppm (CO) ≤ 0.26 Vol.-% (CO2) ≤ 116 ppm (CO) ≤ ± 0.06 Vol.-% (CO2) ≤ ± 35 ppm (CO) ≤ ± 0.02 Vol.-% over 1000 h period (CO2) ≤ ± 60 ppm over 1000 h period (CO) Basic information Display: Analogue output: 4-20 mA (in operation) 2 mA (Warm-up or alarm) Load resistance: Alarm output: Device status alarm // Measurement channel level alarm Relay will close and isolate if alarm limits are exceeded 1 A Trigger (250 V AC / 2 A, resistive load) Power...
Open the catalog to page 2Gas flow & Environment information Gas Inlet flow: (0.4 ~ 0.8) L/min (flow fluctuation ≤ 0.02 L/min) non-condensing Inlet dew point: 5°C ± 0.1°C 99.999 % N2 (NDIR) Clean air, free of sample gas (Photoacoustic) 75 % ~ 110 % of span point Clean air (0 ~ 25 % O2 measurement) Operation temperature: Typical values related to 1013 hPa, Ta = 22 °C, flow = 0.7 l / min for dry (not condensing) and clean sample gas. Stated values exclude calibration gas tolerance. All rights reserved. Any logos and/or product names are trademarks of smartGAS. The reproduction, transfer, distribution or storage of...
Open the catalog to page 3All SmartGAS Mikrosensorik GmbH catalogs and technical brochures
-
PA-232104-00000
2 Pages
-
PA-032204-00000
2 Pages
-
PA-032105-00000
2 Pages
-
B3-702205-03000
2 Pages
-
B3-862205-03000
2 Pages
-
B3-732105-03000
2 Pages
-
B3-732205-03000
2 Pages
-
B3-722205-03000
2 Pages
-
B3-712105-03000
2 Pages
-
B3-712205-03000
2 Pages
-
B3-742205-03000
2 Pages
-
B3-752105-03000
2 Pages
-
B3-802105-03000
2 Pages
-
B3-802205-03000
2 Pages
-
B3-822205-03000
2 Pages
-
B3-752205-03000
2 Pages
-
B3-762205-03000
2 Pages
-
B3-832205-03000
2 Pages
-
B3-842205-03000
2 Pages
-
B3-872205-03000
2 Pages
-
B3-892205-03000
2 Pages
-
B3-772105-03000
2 Pages
-
B3-772205-03000
2 Pages
-
B3-852205-03000
2 Pages
-
: B3-782105-03000
2 Pages
-
B3-782205-03000
2 Pages
-
B3-812105-03000
2 Pages
-
B3-812205-03000
2 Pages
-
B3-722105-03000
2 Pages
-
B3-712205-03800
3 Pages
-
AX-032150-00000
3 Pages
-
AX-212200-00000
3 Pages
-
AX-212223-43000
3 Pages
-
AX-212121-00000
3 Pages
-
AX-210000-00000
3 Pages
-
AX-215000-00000
3 Pages
-
AX-600000-00000
3 Pages
-
T4-602204-03000
2 Pages
-
PA-242204-00000
2 Pages
-
F3-042157-05005
2 Pages
-
Sulfur Dioxide SO2 2000 ppm
2 Pages
-
Carbon dioxide CO2 5000 ppm
2 Pages
-
Carbon dioxide CO2 1000 ppm
2 Pages
-
Carbon dioxide CO2 50 Vol.-%
2 Pages
-
Carbon dioxide CO2 30 Vol.-%
2 Pages
-
Carbon dioxide CO2 20 Vol.-%
2 Pages
-
Carbon dioxide CO2 10 Vol.-%
2 Pages
-
Carbon dioxide CO2 5 Vol.-%
2 Pages
-
Carbon dioxide CO2 2 Vol.-%
2 Pages
-
Carbon dioxide CO2 2000 ppm
2 Pages
-
Carbon dioxide CO2 500 ppm
2 Pages
-
Carbon dioxide CO2 100 ppm
2 Pages
-
Carbon dioxide CO 10.000 ppm
2 Pages
-
Carbon monoxide CO 5000 ppm
2 Pages
-
Carbon monoxide CO 10 Vol.-%
2 Pages
-
Carbon monoxide CO 5 Vol.-%
2 Pages
-
Carbon monoxide CO 2 Vol.-%
2 Pages
-
Carbon monoxide CO 2000 ppm
2 Pages
-
Carbon monoxide CO 50 Vol.-%
2 Pages
-
Carbon monoxide CO 30 Vol.-%
2 Pages
-
Carbon monoxide CO 20 Vol.-%
2 Pages
-
Carbon monoxide CO 15 Vol.-%
2 Pages
-
FLow_Evo_CH4_CH3Br_5.8Vol.-%
2 Pages
-
Methane CH4 5000 ppm
2 Pages
-
Methane CH4 100 Vol.-%
2 Pages
-
Methane CH4 50 Vol.-%
2 Pages
-
Methane CH4 15 Vol.-%
2 Pages
-
Methane CH4 5 Vol.-%
2 Pages
-
Flow Evo CH4 2.5Vol
2 Pages
-
Ethylene C2H4
2 Pages
-
FLOW EVO CH4 10 Vol.-%
2 Pages
-
PAS
4 Pages
-
SILAREX
4 Pages
-
FLOW EVO
2 Pages
-
TRANSMITTER EVO
2 Pages
-
ANAREX
4 Pages