video corpo

AX-212200-00100

AX-212200-00100

AX-212200-00100

Product catalog summary
Overview: The ANAREX Multigas Analyzer by smartGAS Mikrosensorik GmbH is a high-performance solution designed for industrial gas measurement applications. It features easy operation via a touch screen, simple sensor calibration, and is suitable for installation in a 19" rack. The analyzer supports both analog and digital outputs and utilizes various sensor technologies including photoacoustic, NDIR, paramagnetic, and electrochemical sensors.
Specifications:
  • Measurement Principle: NDIR for CO2 and CO.
  • Measurement Range: 0-20 Vol.-% for CO2 and 0-10,000 ppm for CO.
  • Detection Limits: ≤ 0.26 Vol.-% for CO2 and ≤ 116 ppm for CO.
  • Repeatability: ≤ ± 0.06 Vol.-% for CO2 and ≤ ± 35 ppm for CO.
  • Drift: ≤ ± 0.02 Vol.-% over 1000 hours for CO2 and ≤ ± 60 ppm over 1000 hours for CO.
General Features:
  • Display: 5.6” LCD touch screen.
  • Analog Output: 4-20 mA during operation, 2 mA during warm-up or alarm.
  • Alarm Output: Device status and measurement channel level alarms with relay closure.
  • Communication: RS232 (DB-9 Female).
  • Power: 198-242 V AC, 50/60 Hz with a 3A fuse.
  • Protection Level: IP42.
  • Weight: 15 kg.
Gas Flow & Environmental Conditions:
  • Gas Inlet Flow: 0.4-0.8 L/min with ≤ 0.02 L/min fluctuation.
  • Gas Temperature: 5-35°C.
  • Gas Pressure: 76-116 kPa.
  • Humidity: Non-condensing, 0-95% RH.
  • Zero Gas: 99.999% N2 for NDIR, clean air for photoacoustic.
  • Span Gas: 75-110% of span point, clean air for O2 measurement.
  • Operation Temperature: 10-40°C.
Additional Information: The document emphasizes the importance of recalibration at first initiation and recommends recurring recalibration cycles. It also notes that specifications are subject to change and advises consulting smartGAS sales for specific requirements.
See more

Catalog excerpts

AX-212200-00100-1

ANAREX Multigas Analyzer AX-212200-00100 Multigas analyzer Easy operation via touch screen Easy sensor calibration Best measurement performance For installation in a 19" rack Analog or digital output Photoacoustic sensors NDIR sensors Paramagnetic sensors Technology Electro chemical sensors The ANAREX gas analyzers of smartGAS are high-performance solutions for various sectors of industrial gas measurement technology. The fields of application range from process measurement technology and emissions to fruit ripening. It convinces with its highly accurate and stable measurement performance as well as its customer-friendly interfacing via touch screen along with a simple sensor calibration. The ANAREX is designed as a multi-gas analyzer and is suitable for installation in a 19" rack. The smartGAS analyzer can also use different technologies to fulfil all kinds of application requirement. The smartGAS Analyzer is equipped with a 5.6" touch screen, that displays the gas concentration as real-time reading. The internal software is designed to control zero, span and third point calibration to ensure a perfect accuracy of the measurement values. Application examples Emission monitoring CEMS Process control Measuring principles Infrared NDIR Peripherals Gas cooler Pumps Particle filter Tubes Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Customizing options Measuring gases Detection ranges Design and Software Gas pre treatment

 Open the catalog to page 1
AX-212200-00100-2

General features Measurement principle: Measurement range: Detection Limits: Repeatabiliy Drift: CO2 … NDIR CO … NDIR 0 … 20 Vol.-% (CO2) 0 … 10,000 ppm (CO) ≤ 0.26 Vol.-% (CO2) ≤ 116 ppm (CO) ≤ ± 0.06 Vol.-% (CO2) ≤ ± 35 ppm (CO) ≤ ± 0.02 Vol.-% over 1000 h period (CO2) ≤ ± 60 ppm over 1000 h period (CO) Basic information Display: Analogue output: 4-20 mA (in operation) 2 mA (Warm-up or alarm) Load resistance: Alarm output: Device status alarm // Measurement channel level alarm Relay will close and isolate if alarm limits are exceeded 1 A Trigger (250 V AC / 2 A, resistive load) Power connection:...

 Open the catalog to page 2
AX-212200-00100-3

Gas flow & Environment information Gas Inlet flow: (0.4 ~ 0.8) L/min (flow fluctuation ≤ 0.02 L/min) non-condensing Inlet dew point: 5°C ± 0.1°C 99.999 % N2 (NDIR) Clean air, free of sample gas (Photoacoustic) 75 % ~ 110 % of span point Clean air (0 ~ 25 % O2 measurement) Operation temperature: Typical values related to 1013 hPa, Ta = 22 °C, flow = 0.7 l / min for dry (not condensing) and clean sample gas. Stated values exclude calibration gas tolerance. All rights reserved. Any logos and/or product names are trademarks of smartGAS. The reproduction, transfer, distribution or storage of information...

 Open the catalog to page 3

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. Ethylene C2H4

    2  Pages

  2. PAS

    4  Pages

  3. SILAREX

    4  Pages

  4. FLOW EVO

    2  Pages

  5. ANAREX

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.