Multigas analyzer Easy operation via touch screen Easy sensor calibration Best measurement performance For installation in a 19" rack Analog or digital output Photoacoustic sensors NDIR sensors Paramagnetic sensors Technology Electro chemical sensors The ANAREX CEMS analyzer of smartGAS is a high-performance solution for TOC and process control applications. It convinces with its highly accurate and stable measurement performance as well as its customerfriendly interfacing via touch screen along with a simple sensor calibration. The ANAREX is designed as a multi-gas analyzer and is suitable for installation in a 19" rack. The smartGAS analyzer can also use different technologies to fulfil all kinds of application requirement. The smartGAS Analyzer is equipped with a 5.6" touch screen, that displays the gas concentration as real-time reading. The internal software is designed to control zero, span and third point calibration to ensure a perfect accuracy of the measurement values. Application examples TOC Process control Measuring principles Infrared NDIR Peripherals Gas cooler Pumps Particle filter Tubes Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I sales@smartgas.eu I www.smartgas.eu Customizing options Measuring gases Detection ranges Design and Software Gas pre treatment

Open the catalog to page 1
AX-212121-00000 - 2

General features Measurement principle: Measurement range: 0 … 100 ppm 0 … 1,000 ppm 0 … 10,000 ppm ≤ 2.6 ppm ≤ 21.6 ppm ≤ 130 ppm ≤ ± 0.4 ppm ≤ ± 3.5 ppm ≤ ± 35 ppm ≤ ± 2.4 ppm over 1000 h period ≤ ± 16 ppm over 1000 h period ≤ ± 461 ppm over 1000 h period Detection Limits: Basic information Display: Analogue output: 4-20 mA (in operation) 2 mA (Warm-up or alarm) Load resistance: Alarm output: Device status alarm // Measurement channel level alarm Relay will close and isolate if alarm limits are exceeded 1 A Trigger (250 V AC / 2 A, resistive load) Power connection: Rated current: 3A;...

Open the catalog to page 2
AX-212121-00000 - 3

non-condensing Inlet dew point: 5°C ± 0.1°C 99.999 % N2 (NDIR) Clean air, free of sample gas (Photoacoustic) 75 % ~ 110 % of span point Clean air (0 ~ 25 % O2 measurement) Operation temperature: Typical values related to 1013 hPa, Ta = 22 °C, flow = 0.7 l / min for dry (not condensing) and clean sample gas. Stated values exclude calibration gas tolerance. All rights reserved. Any logos and/or product names are trademarks of smartGAS. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of smartGAS is...

Open the catalog to page 3

All SmartGAS Mikrosensorik GmbH catalogs and technical brochures

  1. PAS

    4 Pages

  2. SILAREX

    4 Pages

  3. FLOW EVO

    2 Pages

  4. ANAREX

    4 Pages