Overview: The ANAREX Multigas Analyzer by smartGAS Mikrosensorik GmbH is a high-performance solution designed for various industrial gas measurement applications, including emission monitoring, biogas, process control, and fruit ripening. It features easy operation via a touch screen, simple sensor calibration, and is suitable for installation in a 19" rack.
Key Features:
  • Utilizes multiple sensor technologies: photoacoustic, NDIR, paramagnetic, and electrochemical sensors.
  • Equipped with a 5.6" touch screen for real-time gas concentration readings.
  • Supports analog or digital output and offers customizable options for measuring gases and detection ranges.
Measurement Principles and Ranges:
  • C2H4: Photoacoustic, 5-1000 ppm range, detection limit ≤ 5 ppm.
  • CO2: NDIR, 0-5 Vol.-% range, detection limit ≤ 0.03 Vol.-%.
  • O2: Paramagnetic, 0-25 Vol.-% range, detection limit ≤ ± 0.03 Vol.-%.
Technical Specifications:
  • Display: 5.6” LCD touch screen.
  • Analog output: 4-20 mA, with alarm and warm-up indicators.
  • Communication: RS232 interface.
  • Power: 198-242 V AC, 50/60 Hz, with a 3A fuse.
  • Protection level: IP42.
  • Weight: 15 kg.
Environmental and Operational Conditions:
  • Gas inlet flow: 0.4-0.8 L/min, with minimal flow fluctuation.
  • Operating temperature: 10°C to 40°C.
  • Humidity: 0-90% RH, non-condensing.
  • Pressure: 76-116 kPa.
Additional Information: The document emphasizes the importance of recalibration at first initiation and periodically, depending on application and ambient conditions. It also notes that specifications are subject to change and advises consulting smartGAS for specific requirements.
See more

Catalog excerpts

AX-032150-00000-1

ANAREX Multigas Analyzer AX-032150-00000 Multigas analyzer Easy operation via touch screen Easy sensor calibration Best measurement performance For installation in a 19" rack Analog or digital output Photoacoustic sensors NDIR sensors Paramagnetic sensors Technology Electro chemical sensors The ANAREX gas analyzers of smartGAS are high-performance solutions for various sectors of industrial gas measurement technology. The fields of application range from process measurement technology and emissions to fruit ripening. It convinces with its highly accurate and stable measurement performance as well as its customer-friendly interfacing via touch screen along with a simple sensor calibration. The ANAREX is designed as a multi-gas analyzer and is suitable for installation in a 19" rack. The smartGAS analyzer can also use different technologies to fulfil all kinds of application requirement. The smartGAS Analyzer is equipped with a 5.6" touch screen, that displays the gas concentration as real-time reading. The internal software is designed to control zero, span and third point calibration to ensure a perfect accuracy of the measurement values. Application examples Emission monitoring CEMS Biogas Process control Fruit ripening High voltage Measuring principles Infra red NDIR Photo accoustic Electro chemical Paramagnetic O2 Peripherals Gas cooler Pumps Particle filter Tubes Mounting equipment smartGAS Mikrosensorik GmbH I Huenderstr. 1 I 74080 Heilbronn I Germany T +49 7131 797553-0 I F +49 7131 797553-10 I [email protected] I www.smartgas.eu Customizing options Measuring gases Detection ranges Design and Software Gas pre treatment Global Datasheet ANAREX E

 Open the catalog to page 1
AX-032150-00000-2

General features Measurement principle: Measurement range: Detection Limits: C2H4 … Photoacoustic CO2 … NDIR O2 … Paramagnetic 5 ... 1000 ppm (C2H4) 0 … 5 Vol.-% (CO2) 0 …25 Vol.-% (O2) ≤ 5 ppm (C2H4) ≤ 0.03 Vol.-% (CO2) ≤ ± 0.03 Vol.-% (O2) ≤ 1% of measured value plus ± 1.5 ppm (C2H4) ≤ ± 0.04 Vol.-% (CO2) ≤ ± 0.03 Vol.-% (O2) ≤ 1% of value ± 3 ppm over 24 h period (C2H4) ≤ ± 0.6 Vol.-% over 1000 h period (CO2) ≤ ± 0.1 Vol.-% over 168 h period (O2) Basic information Display: Analogue output: 4-20 mA (in operation) 2 mA (Warm-up or alarm) Load resistance: Alarm output: Device status alarm //...

 Open the catalog to page 2
AX-032150-00000-3

Gas flow & Environment information Gas Inlet flow: (0.4 ~ 0.8) L/min (flow fluctuation ≤ 0.02 L/min) non-condensing Inlet dew point: 5°C ± 0.1°C 99.999 % N2 (NDIR) Clean air, free of sample gas (Photoacoustic) 75 % ~ 110 % of span point Clean air (0 ~ 25 % O2 measurement) Operation temperature: Typical values related to 1013 hPa, Ta = 22 °C, flow = 0.7 l / min for dry (not condensing) and clean sample gas. Stated values exclude calibration gas tolerance. All rights reserved. Any logos and/or product names are trademarks of smartGAS. The reproduction, transfer, distribution or storage of information...