ICP-MS2000
1 /2Pages

ICP-MS2000

ICP-MS2000
1 /2Pages

Catalog excerpts

ICP-MS2000-1

Skyray Instrument TO BE A WORLD-LEADING ANALYTICAL TESTING SOLUTIONS PROVIDER ! □ Inletsystenrlt has open-type inlet stem structure, outside installing atomizer which location by itself and needn’t be adjusted O Peristaltic pump:The Low Pulse peristaltic pump which the computer controlled 3 channels and 12 rollers can be adjust rotate speed n Atomizer:The atomizer is a quartz glass concentric atomizer. (0.8 mL/min) Atomizing chamber:The high-purity quartz atomizing chamber which use semiconductor refrigerating plant is a small size, short memory effect, single channel, pear shape, Impact bead possessed atomizing chambe □ Torch tube.The quartz torch tube has 1.5 mm caliber to spray □ 1CP source:27.12 MHz Solid State Technology, water-cooling, power 1600 W controlled by computer, fire up automatically Cl Adjustment system of torch tube position:The computer controls x, y, z three-dimensional accurate position. All the tuning parameter is accessed to analytical method □ Control system of gases:3 mass flow meters controlled by computer controls all the gas flow atomization gas, Aux gas, plasma gas □ Power-off protection system:when power off, it can shut down by itself with no damage the instrument system □ Connector:Nickel Cone special event connector structure, easy to replace, installation, demolition, sampling and skimmer cone □ Activities valve:lt is a computer control valv. It protect instrument vacuum convenient for installing and dismantling sampling cone and skimmer cone when the vacuum system working □ Ion lens systemdt has high efficiency hexapole ion guiding system. In all the mass range, it can get the best ion transmission efficiency. It has Ions deflection system. Lens installation and easy removal □ Quadrupoles characteristic:Mo Quadrupoie, main Quadrupole 180 mm»12 mm, head Quadrupole 20 mmxl2 mm, uncover to Installing and dismantling □ Quadrupoles RF generatonair patenting, solid state, 2.0 MHz, mass number adjust stability <0.05 amu/day □ Mass spectra range:2~255 amu □ Detector:ETP dual mode detector, Divided into two parts in dynode electron multiplier, without digital / analog switch □ Test range:>10“ □ Multichannel signal analyzer:65000 channels to adapt to the requirements of the transient signal analysis □ Signal acquisition mode:Jump peak, scanning, sectional scanning, at the same time jump peak and scanning of mixed type □ Software:To provide automatic control instruments and their accessories ability, Windows 2000/XP/vista/win7(32 bit or 64 bit) Professional operating system □ Water circulation system:Temperature control: 10-40'C; Minimum velocity:5L/Min, Pressure control:0-600 kPa Contact the Leader in XRF Analysis Skyray Instrument Inc. 50 Braintree Hill Park, Suite 201 Braintree, MA 02184 USA www.skyrayinstrument.com email: [email protected] tel: 617.202.3879 ICP-MS 2000 Inductively Coupled Plasma Mass Spectrometry • Cost-effective • Satisfy the clientele's requirements • Quick analysis speed

 Open the catalog to page 1
ICP-MS2000-2

ICP-MS 2000 Inductively Coupled Plasma Mass Spectrometry ICP-MS 2000-good analyse effect! Skyray Instrument Inductively Coupled Plasma Mass Spectrometry Introduction: Inductively Coupled Plasma Mass Spectrometry (ICP-MS),has a microscale(10'6), trace(10'9), ultratrace(10'12) element analyses technique. It can analyses most of the elements in the periodic table. It has very low detection limit, wide trends linearity range, lew interference, high accuracy, high analyzed speed, and it also can analyze isotope. Instrument features: □ Open-type inlet system, plug-in installing atomizer, self positioning,...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.