SNP-Z15 series
4Pages

{{requestButtons}}

Catalog excerpts

SNP-Z15 series - 1

General Purpose Rated 150W Peak 220W SNP-Z15 Series Only 1.5 inch height With ITE & Medical safety Operation from 0oC to 70oC by convection Mechanical Specifications: Screw protrusion customer system Chassis Mounting screw BOTTOM VIEW Dimensions shown in mm as left. Tolerance: +/-1mm (Excluding cables). Size: 96.5 X 172.7 X 38.1 (mm) 3.8" X 6.8" X 1.5" Packing: Net weight: 555 g / unit Gross weight: 13.7 kg / carton, 20 units / carton Carton size (mm): 453 (L) x 362 (W) x 279 (H) Connectors (a) TB1-AC input : Molex 5277-02A or equivalent (b) TB2-DC output : Molex 5273-12A and Molex 5273-09A (c) TB3-LED : Molex 5045-02A or equivalent for all models (d) TB4-FAN : Molex 5045-02A or equivalent for all models (e) TB4-Remote sense : Molex 5045-02A or equivalent for SNP-Z156 Output Pin assignment: PIN NO. AUG. 2012 ** This data sheet is only for models selection. For business, engineering specification by model must be used.

Open the catalog to page 1
SNP-Z15 series - 2

General Purpose Rated 150W Peak 220W SNP-Z15 Series Output Specifications: OUTPUT RAIL EFFICIENCY TYPICAL 1. Each output can last for 8 seconds without shut down. 2. At factory, all outputs in 60% rated load condition, each output is checked to be within voltage accuracy range while the main output is setting to within the specified accuracy range at rated load. 3. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 4. Load regulation is defined by changing ±40% of measured output load from 60% rated load at another output set to 60% rated load. 5....

Open the catalog to page 2
SNP-Z15 series - 3

General Purpose Rated 150W Peak 220W SNP-Z15 Series Performance for SNP-Z157: 1. Switching frequency ripple 2. Line frequency ripple 3. Output turn on wave form 4. Output turn off wave form 6. Over voltage protection Trip point around 15V AUG. 2012 ** This data sheet is only for models selection. For business, engineering specification by model must be used.

Open the catalog to page 3
SNP-Z15 series - 4

General Purpose other output at 60% rated load other output at 60% rated load 11. Power derating curve Rated load Operating Temperature This data sheet is only for models selection. For business, engineering specification by model must be used. AUG. 2012

Open the catalog to page 4

All Skynet Electronic catalogs and technical brochures

  1. SNP-F series

    2 Pages

  2. SNP-P series

    4 Pages

  3. SNP-V127

    4 Pages

  4. SNP-AF69

    4 Pages

  5. D12-AX25

    4 Pages

  6. SNP-CK66

    4 Pages

  7. SNP-H069-M

    1 Pages

  8. SNP-P15G-SM

    1 Pages

  9. SNP-P15G-S

    1 Pages

  10. SNP-P159-SM

    1 Pages

  11. SNP-P159-S

    1 Pages

  12. SNP-825A

    4 Pages

Archived catalogs