SNP-Z06 series

SNP-Z06 series

SNP-Z06 series

Product catalog summary
Overview: The document is a technical data sheet for the SNP-Z06 Series power supply, intended for model selection purposes. It provides specifications, features, and performance details for various models within the series.
General Specifications:
  • Input Voltage: 90VAC to 264VAC
  • Input Frequency: 47Hz to 63Hz
  • Inrush Current: Less than 40A at 115VAC and less than 70A at 230VAC (cold start, 25°C)
  • Efficiency: Ranges from 77% to 87% depending on the model
  • Hold-up Time: 15ms typical at rated load and 115VAC or 230VAC
  • Protection: Overload and short circuit protection with auto recovery; over voltage protection with latch off
  • Operating Temperature: 0°C to 70°C with derating above 50°C
  • Cooling: Free air convection
  • Storage Temperature: -40°C to +85°C
  • EMI Compliance: FCC "B", EN55022 "B", EN55011 "B"
  • EMS Compliance: EN61000-4-2,-3,-4,-5,-6,-8,-11
  • Safety Standards: UL 60950-1, UL 60601-1, CSA C22.2 No. 60950-1, No. 60601.1, EN 60950-1, EN 60601-1
Mechanical Specifications:
  • Dimensions: 50.8 x 101.6 x 30 mm (2" x 4" x 1.18")
  • Weight: Net 140g per unit; Gross 13.5kg per carton (80 units per carton)
  • Connectors: AC input - JST B6P3-VH or equivalent; DC output - JST B6P-VH or equivalent for single output, JST B7P-VH or equivalent for multiple outputs
Output Specifications:
  • Peak Load Duration: 8 seconds without shutdown
  • Combinational Load: Maximum 30W for SNP-Z06D model (+3.3V & +5V)
  • Line Regulation: ±10% input voltage change at rated load
  • Load Regulation: ±40% output load change from 60% rated load
  • Ripple & Noise: Measured with 15MHz bandwidth limited oscilloscope
  • Efficiency: Measured at nominal line and rated load
Model-Specific Output Details:
  • SNP-Z061: +5V, +12V, -12V outputs with specific load and voltage accuracy
  • SNP-Z06D: +3.3V, +5V, +12V outputs with specific load and voltage accuracy
  • Other models (SNP-Z063, SNP-Z06A, etc.) have similar detailed specifications for different voltage outputs
Performance Characteristics:
  • Switching Frequency Ripple
  • Output Turn On/Off Waveform
  • Step Response for +5V and +12V
  • Over Voltage Protection
  • Compliance with FCC B and EN 55022 B standards
  • Power Derating Curve
See more

Catalog excerpts

SNP-Z06 series-1

Rated 65W Peak 90W SNP-Z06 Series General Purpose Only 1.18 inch height With ITE & Medical safety Operation from 0oC to 70oC by convection Mechanical Specifications: TO CHASSIS GROUND, INDICATED "A" x3 101.6 Dimensions shown in mm as left. Tolerance: + -0.4mm. Size: 50.8 X 101.6 X 30 (mm) 2" X 4" X 1.18" Packing: Net weight: 140 g approx. / unit Gross weight: 13.5 kg approx. / carton, 80 units / carton Carton size (mm): 382 (L) x 374 (W) x 277 (H) Connectors: AC input : JST B6P3-VH or equivalent DC output : JST B6P-VH or equivalent for single output JST B7P-VH or equivalent for multiple outputs Output Pin assignment: PIN NO. SNP-Z061 SNP-Z06D SNP-Z063 SNP-Z06A SNP-Z066-1 SNP-Z067 SNP-Z067-1 SNP-Z068 SNP-Z068-1 SNP-Z069 SNP-Z069-1 SNP-Z06T ** This data sheet is only for model selection. For business, engineering specification by model must be used.

 Open the catalog to page 1
SNP-Z06 series-2

Rated 65W Peak 90W SNP-Z06 Series General Purpose Output Specifications: OUTPUT RAIL RIPPLE NOISE EFFICIENCY TYPICAL 1. At peak load, the output can last for 8 seconds without shut down. 2. The maximum combinational load of SNP-Z06D for +3.3V & +5V is 30W. 3. At factory, all outputs in 60% rated load condition, each output is checked to be within the accuracy range while the main output is setting to within the specified accuracy range at rated load. 4. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. 5. Load regulation is defined by changing ±40%...

 Open the catalog to page 2
SNP-Z06 series-3

General Purpose Rated 65W Peak 90W SNP-Z06 Series Performance for SNP-Z061: 1. Switching frequency ripple 2. Line frequency ripple 4. Output turn off wave form 3. Output turn on wave form 6. Over voltage protection Trip point around 6.4V ** This data sheet is only for model selection. For business, engineering specification by model must be used.

 Open the catalog to page 3
SNP-Z06 series-4

General Purpose 11. Power derating curve Rated load - Operating Temperature This data sheet is only for model selection. For business, engineering specification by model must be used.

 Open the catalog to page 4

All Skynet Electronic catalogs and technical brochures

  1. SNP-F series

    2  Pages

  2. SNP-P series

    4  Pages

  3. SNP-V127

    4  Pages

  4. SNP-AF69

    4  Pages

  5. D12-AX25

    4  Pages

  6. SNP-CK66

    4  Pages

  7. SNP-H069-M

    1  Page

  8. SNP-P15G-SM

    1  Page

  9. SNP-P15G-S

    1  Page

  10. SNP-P159-SM

    1  Page

  11. SNP-P159-S

    1  Page

  12. SNP-825A

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.