SNP-X12 Series

SNP-X12 Series

SNP-X12 Series

Product catalog summary
Mechanical Specifications:
1. Dimensions: 76.2 x 127 x 33.5 mm (3" x 5" x 1.319"). Tolerance: +/-0.4mm.
2. Weight: Net 290g per unit; Gross 13.0 kg per carton (36 units).
3. Connectors: AC input - Molex 5277-02A; DC output - Molex 5273; Remote Sense - Molex 5045-02A.
Protection and Performance:
- Short circuit protection: Auto recovery.
- Over voltage protection: Latch off.
- Max capacitive load: 30000uF.
- Remote Sense: Compensates for 0.5V load drop min.
- Operating temperature: -20°C to 70°C (derating 2.5%/°C > 40°C).
- Cooling: Free air convection for 120W, 18CFM forced air for 130W.
- Storage temperature: -20°C to +85°C.
- EMI: EN55022 "B", FCC "B".
- Harmonics: EN61000-3-2.
- EMS: EN61000-4-2,-3,-4,-5,-6,-11.
- Safety: UL60950-1, EN 60950-1, ANSI/AAMI ES60601-1, EN 60601-1.
Electrical Specifications:
- Input voltage: 90 VAC to 264 VAC.
- Input frequency: 47 Hz to 63 Hz.
- Inrush current: <30A at 115VAC, <60A at 230VAC (cold start, 25°C).
- Efficiency: 87% typical.
- Hold up time: 20ms typical at rated load and 115VAC.
- Average efficiency: >87% at 25%, 50%, 75%, 100% of rated load.
- No-load input power: <0.5W.
- Energy saving: Energy Star Ver. 2.0.
- Overload protection: Auto recovery.
Features:
- Meets Energy Star Version 2.0.
- Built-in active PFC.
- Height: 1.36 inches.
- Power density: 5.8 Watt per cubic inch.
- ITE & Medical safety compliant.
- Efficiency: 85% to 90%.
- Operating temperature range: -20°C to 70°C by convection.
Output Specifications:
- SNP-X127: +12V, 0A to 11A, Voltage accuracy: +11.9V~+12.1V, Ripple: 120mVpp.
- SNP-X128: +15V, 0A to 8.8A, Voltage accuracy: +14.25V~+15.25V, Ripple: 120mVpp.
- SNP-X125: +18V, 0A to 7.4A, Voltage accuracy: +17.1V~+18.9V, Ripple: 100mVpp.
- SNP-X129: +24V, 0A to 5.5A, Voltage accuracy: +23.8V~+24.2V, Ripple: 200mVpp.
- SNP-X12T: +48V, 0A to 2.75A, Voltage accuracy: +47.5V~+50.4V, Ripple: 200mVpp.
- SNP-X12H: +60V, 0A to 2.4A, Voltage accuracy: +57V~+63V, Ripple: 150mVpp.
Notes:
1. Total output current is rated load with free air convection and max. load with 18CFM of forced air flow.
2. Voltage accuracy checked at 60% rated load.
3. Line regulation defined by changing ±10% of input voltage.
4. Load regulation defined by changing ±40% of measured output load.
5. Ripple & noise measured with 15MHz bandwidth limited oscilloscope.
6. Hold up time measured from end of last charging pulse.
7. Efficiency measured at rated load and nominal line.
See more

Catalog excerpts

SNP-X12 Series-1

General Purpose Rated 120W SNP-X12 Series ITE & Medical Safety Meet Energy Star Version 2.0 With built-in active PFC Only 1.36 inch height 5.8 Watt per cubic inch With ITE & Medical safety Operation from -20oC to 70oC by convection Mechanical Specifications: Dimensions shown in mm as left. Tolerance: +/-0.4mm. Size: 76.2 X 127 X 33.5 (mm) 3" X 5" X 1.319" Packing: Net weight: 290 g approx. / unit Gross weight: 13.0 kg approx. / carton, 36 units / carton Carton size (mm): 339 (L) x 339 (W) x 327 (H) Connectors: AC input : Molex 5277-02A or equivalent DC output : Molex 5273 or equivalent Remote Sense : Molex 5045-02A or equivalent ** This data sheet is only for models selection. For business, engineering specification by model must be used.

 Open the catalog to page 1
SNP-X12 Series-2

General Purpose Rated 120W SNP-X12 Series ITE & Medical Safety Output Specifications: LINE LOAD The total output current is rated load with free air convection and max. load with 18CFM of forced air flow over the unit. At factory, in 60% rated load condition, each output is checked to be within voltage accuracy. Line regulation is defined by changing ±10% of input voltage from nominal line at rated load. Load regulation is defined by changing ±40% of measured output load from 60% rated load at another output set to 60% rated load. 5. Ripple & noise is measured by using 15MHz bandwidth limited...

 Open the catalog to page 2
SNP-X12 Series-3

General Purpose Performance for SNP-X127 (input voltage is 115VAC, unless others specified); 1. Switching frequency ripple 2. Line frequency ripple 3. Output turn on wave form JUL. 2013 ** This data sheet is only for models selection. For business, engineering specification by model must be used.

 Open the catalog to page 3
SNP-X12 Series-4

General Purpose 10. Power derating curve Rated load Operating Temperature ** This data sheet is only for models selection. For business, engineering specification by model must be used.

 Open the catalog to page 4

All Skynet Electronic catalogs and technical brochures

  1. SNP-F series

    2  Pages

  2. SNP-P series

    4  Pages

  3. SNP-V127

    4  Pages

  4. SNP-AF69

    4  Pages

  5. D12-AX25

    4  Pages

  6. SNP-CK66

    4  Pages

  7. SNP-H069-M

    1  Page

  8. SNP-P15G-SM

    1  Page

  9. SNP-P15G-S

    1  Page

  10. SNP-P159-SM

    1  Page

  11. SNP-P159-S

    1  Page

  12. SNP-825A

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.