SKF 728619 E

SKF 728619 E
1 / 188 PagesView full catalog

SKF 728619 E

Product catalog summary
Safety Precautions: The document highlights the necessity of thoroughly reading instructions and adhering to safety measures to prevent injuries or damage. Key points include ensuring only trained personnel operate the equipment, wearing protective gear, inspecting equipment before use, and using recommended hydraulic oils. It warns against using damaged components, exceeding maximum hydraulic pressure, and modifying equipment.
EU and UK Declarations of Conformity: The product complies with the Machinery Directive 2006/42/EC and the Supply of Machinery (Safety) Regulations 2008, conforming to standards EN-ISO 12100:2010 and EN-ISO 4413.
Description: The SKF 728619 E is a two-stage pump designed for high flow rates below switching pressure, with automatic flow reduction above it. It includes a high-pressure hose with quick-connection couplings and comes prefilled with SKF mounting fluid.
Technical Data: The pump operates at a maximum pressure of 150 MPa, with specific volume per stroke details provided. It includes a 3-meter pressure hose and has a weight of 11.4 kg when filled with oil.
Operating Instructions: Instructions include checking oil levels, maintaining a horizontal pump position, and ensuring proper connection of the quick connection nipple. It advises on the use of specific oil viscosities for mounting and dismounting bearings.
Maintenance: Maintenance involves filling the oil container correctly, ensuring no air in the system, and using clean hydraulic oils. It provides guidance on connecting hoses and operating the pump safely.
Storage and Transportation: The document advises storing the equipment in a dry, well-ventilated area, with specific temperature and humidity conditions. It emphasizes using the provided carrying case for transportation to prevent damage.
Specifications: Key specifications for the hydraulic pump model 728619 E include a maximum pressure of 150 MPa, a weight of 11.4 kg when filled with oil, and a handle force of 370 N. The pump dimensions are A: 170 mm, B: 620 mm, C: 130 mm, and D: 128 mm. The oil viscosity for operation is specified at 300 mm²/s for assembly and 900 mm²/s for disassembly at 20°C.
Usage Instructions: Usage instructions include checking the oil level by removing the tank plug under the pump handle, ensuring the pump is kept horizontal, and securely attaching the quick-connect nipple to the workpiece. The pump should be operated until the required pressure is reached, with a safety valve opening if pressure exceeds 150 MPa. After use, the release valve should be opened to allow oil to flow back into the tank.
Maintenance: Maintenance involves filling the oil tank by placing the pump on a flat surface and ensuring no air is in the oil system. Only clean hydraulic oils like SKF LHMF 300 or LHDF 900 should be used. The document emphasizes the importance of cleanliness to prevent contamination that could reduce the pump's lifespan.
Storage and Transportation: The pump should be stored in a dry, dust-free, well-ventilated area with a relative humidity of less than 75% and a temperature range of +10°C to +40°C. It should be protected from direct sunlight and extreme temperatures. For transportation, the product should be kept in its original container to prevent damage.
Safety Measures: Safety instructions include using the equipment only by trained personnel, wearing appropriate protective gear, and not exceeding the maximum hydraulic pressure. It is crucial to ensure that no air is present in the hydraulic system before increasing pressure.
Compliance and Warranty: The document includes an EC Declaration of Conformity, stating compliance with the Machinery Directive 2006/42/EC and standards EN-ISO 12100:2010 and EN-ISO 4413. It also mentions that the content is protected by copyright and cannot be reproduced without permission.
See more

Catalog excerpts

SKF 728619 E-1

Instructions for use Bedienungsanleitung | Instrucciones de uso | Mode d’emploi | Manuale d’istruzioni | Instruções de uso Инструкция по эксплуатации | 使用说明书 | Ръководство за употреба | Návod k použití | Betjeningsvejledning Οδηγίες χρήσης | Kasutusjuhend | Käyttöohjeet | Upute za korisnike | Használati útmutató | Naudojimo instrukcija Lietošanas instrukcija | Gebruiksaanwijzing | Instruksjoner for bruk | Instrukcja obsługi | Instrucţiuni de utilizare

 Open the catalog to page 1
SKF 728619 E-5

Read this instruction for use fully. Follow all safety precautions to avoid personal injury or property damage during equipment operation. SKF cannot be responsible for damage or injury resulting from unsafe product use, lack of maintenance or incorrect equipment operation. In case of any uncertainties as regards the use of the equipment contact SKF. Failure to comply with the following could cause equipment damage and personal injury. • Do ensure that the equipment is only operated by trained personnel. • Do wear proper personal protective gear, such as eye protection, protective gloves and...

 Open the catalog to page 5
SKF 728619 E-6

EU Declaration of Conformity 728619 E We, SKF MPT, Meidoornkade 14, 3992 AE Houten, The Netherlands herewith declare under our sole responsibility that the products described in these instructions for use, are in accordance with the conditions of the following Directive(s): MACHINERY DIRECTIVE 2006/42/EC and are in conformity with the following standards: EN-ISO 12100:2010, EN-ISO 4413 Houten, The Netherlands, March 2024 1. Description The 728619 E is a two stage pump. The pump supplies a high rate of flow (20 cm3 per stroke) below the switching pressure. Above the switching pressure the flow...

 Open the catalog to page 6
SKF 728619 E-8

• Remove the container plug under the pump handle to check the oil level. Make sure there is sufficient oil to complete the operation. Use oil with a viscosity at operating temperature of 300 mm2/s (1 400 SUS) to mount bearings with the SKF Oil Injection Method or a hydraulic nut. Use oil with a viscosity at operating temperature of 900 mm2/s (4 100 SUS) for dismounting bearings. • Hold the pump in a horizontal position and tilt forward as necessary to make sure the oil supply is constant. • Screw the quick connection nipple (G V4) tightly into the workpiece. Connect the hose to the quick connection...

 Open the catalog to page 8
SKF 728619 E-9

SKF 728619 E4, Double outlet adapter

 Open the catalog to page 9
SKF 728619 E-10

• Dry place without dust, storage in a well-ventilated dry room • Shelf life: max. 36 months. • No direct sunlight or UV radiation. • Protection from nearby sources of heat or cold. Products should be carried out in the carrying case provided by SKF in all instances regardless of distance. In order to ensure proper protection of the products during transportation, reloading and storage, they must be packed in their carrying cases or other packaging materials that protect the product from damage and loss. The contents of this publication are the copyright of the publisher and may not be reproduced...

 Open the catalog to page 10
SKF 728619 E-12

BITTE ZUERST LESEN Sicherheitsvorkehrungen Bedienungsanleitung vollständig lesen. Sicherheitsvorkehrungen befolgen, um Verletzungen an Personen oder Sachschäden während des Betriebs der Ausrüstung zu vermeiden. SKF haftet nicht für Schäden oder Verletzungen, die sich aus einem unsachgemäßen Gebrauch des Produkts, einer mangelhaften Wartung oder einer fehlerhaften Bedienung der Ausrüstung ergeben. Falls Fragen zur Handhabung der Ausrüstung offen sind oder Unsicherheiten bestehen, bitte mit SKF Kontakt aufnehmen. Werden die folgenden Anweisungen nicht beachtet, kann dies zu Schäden an der Ausrüstung...

 Open the catalog to page 12
SKF 728619 E-13

1. Technische Beschreibung Die Pumpe 728619 E ist eine zweistufige Pumpe. Unterhalb des Arbeitsdrucks arbeitet die Pumpe mit einem großen Hubvolumen (20 cm3 per Hub). Oberhalb dieses Arbeitsdrucks beträgt das Hubvolumen automatisch nur noch 1 cm3 pro Hub. Zum Anschluss der Pumpe an ein Bauteil oder Werkzeug wird ein 3 Meter langer Hochdruckschlauch mitgeliefert. Das eine Schlauchende verfügt über eine Schnellkupplung für den Anschluss an die Pumpe. Das andere Ende ist zum Anschluss an das Werkzeug mit einem G 1/4” Anschlussnippel versehen. Die Handpumpe wird mit der SKF Montageflüssigkeit LHMF...

 Open the catalog to page 13
SKF 728619 E-15

Den Öleinfüllstutzen unterhalb des Pumpengriffs öffnen und den Ölstand prüfen. Vergewissern, ob ausreichend Öl vorhanden ist. Drucköle mit einer Viskosität von 300 mm2/s bei Umgebungstemperatur verwenden, wenn Lager mit Hilfe des SKF Drückölverfahrens oder einer SKF Hydraulikmutter montiert werden sollen. Zum Lösen von Lagern auf zylindrischem oder kegeligem Sitz Drucköle mit einer Viskosität von 900 mm2/s bei Betriebstemperatur verwenden. Die Pumpe horizontal oder leicht nach vorne geneigt platzieren, um eine konstante Ölversorgung im Druckzylinder der Pumpe sicherzustellen. Den Schnellschlussnippel...

 Open the catalog to page 15
SKF 728619 E-16

SKF 728619 E4, Adapter fur doppelte Austrittsoffnung

 Open the catalog to page 16
SKF 728619 E-17

Trockene und staubfreie Aufbewahrung in einem gut belufteten Raum • Keine direkte Sonneneinstrahlung oder UV-Strahlung • Schutz vor Warme- bzw. Kaltequellen Bei samtlichen Transportmitteln und Entfernungen hat der Transport im Behalter des Herstellers zu erfolgen. Um die Sicherheit der Produkte beim Transport, Umladen und Aufbewahren der Produkte zu gewahrleisten, mussen diese in Behalter, andere Komponenten und Materialien verpackt sein, die die Produkte vor Beschadigung und Verlust schutzen. Nachdruck, auch auszugsweise, nur mit unserer vorherigen schriftlichen Genehmigung gestattet. Die Angaben...

 Open the catalog to page 17
SKF 728619 E-18

Traducción de las instrucciones originales 16

 Open the catalog to page 18
SKF 728619 E-19

LEA ESTO EN PRIMER LUGAR Recomendaciones de seguridad Lea atentamente estas instrucciones de uso. Respete las normas de seguridad para evitar lesiones personales o daños materiales durante el funcionamiento del equipo. SKF no se responsabiliza de los daños o lesiones derivados del uso no seguro del producto, de la falta de mantenimiento o del funcionamiento incorrecto del equipo. En caso de duda relacionada con el uso del equipo, contacte con SKF. De no cumplirse lo siguiente podrían producirse daños en el equipo y lesiones personales. • Asegúrese de que el equipo sea manejado exclusivamente...

 Open the catalog to page 19

All SKF Maintenance,Lubrication and Power Transmission catalogs and technical brochures

  1. TKBA 21

    2  Pages

  2. THHP 300

    2  Pages

  3. SKF TMJL 100

    136  Pages

  4. SKF 729124

    136  Pages

Archived catalogs

  1. SKF Vibracon

    8  Pages

  2. SKF TWIM 15

    4  Pages

  3. SKF Gloves

    2  Pages

  4. SKF Couplings

    112  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.