Block metering device VPB Block feeder for use in oil or grease lubrication systems
Open the catalog to page 1Block metering device VPB Block metering devices or feeders of the VPBM/VPBG series are used in small circulating-oil lubrication systems as well as in grease and oil total loss lubrication systems. Fields of application are, for example, metal-forming machines, vehicles, production systems in the automotive industry as well as packaging and printing machines. Advantages: • Robust and cost-eficient • Usable for the widest possible range of applications with regards to mode of operation (continuous/intermittent) and lubricants • Central function monitoring of all feeder ports with a minimum of...
Open the catalog to page 2Block metering device VPB General information The block metering device VPB, which belongs to the progressive feeder range, is available in the designs VPBM (metric threaded connectors) and VPBG (inch threaded connectors). The block feeders VPBM and VPBG are pre-set to a fix dosing volume of 0.2 cm3 per outlet and cycle. The volumetric low, which is sent via a tube, is forcibly distributed in a predetermined ratio to the outlets, i.e. to the lubrication points or the downstream progressive feeders. Pistons, which are aligned in series, meter the lubricant for two opposite outlets each and control...
Open the catalog to page 3Block metering device VPB Information on the VPB design The general criteria for the design of progressive feeders also apply without restrictions to the sectional metering device VPB. In case of an installation on movable machine parts or in case of strong vibrations (e.g. on grease guns), the piston position of the feeder should not correspond with the direction of movement of the machine part. A maximum of 200 cycles/min is recommended. The block feeder can be monitored directly by means of a piston detector (compare in the oder code: parameters piston detector, monitoring type P2, P3) and...
Open the catalog to page 4Block metering device VPB, basic design for oil or grease, without attachments, without monitoring Fig. 6 Block feeder VPB, basic design lubricant outlet lubricant inlet Oil 200 bar, grease 300 bar 0.20 cm3 Mineral oils, grease based on mineral oil, environmentally friendly and synthetic oils and greases > 12 mm2/s ≥ 265 x 0.1 mm (up to NLGI-grade 2) Operating pressure max. Volumen per outlet and cycle Lubricant Style Mounting position Screw connection Inlet / outlet Ambient temperature range Feeder sections Quantity of outlets Material Technical Data Operating viscosity Worked penetration VPBM...
Open the catalog to page 5Block metering device VPB monitored by piston detector, for oil and grease with piston detector, electrical Technical Data For further technical data † basic design, page 5 Piston detector, electrical * Internal thread Ambient temperature range Load current max. Protection class Piston detector (short-circuit protection, intermittent and protected against polarity reversal) Design Rated voltage Residual ripple Output function Minimum load current with 4-point-LED, 2 pin connection 10 to 36 V DC 3% to 15% NC contact 4 mA Piston detector, (short-circuit protection, intermittent and protected against...
Open the catalog to page 6Block metering device VPB with 2/2 directional solenoid valve for grease Fig. 9 Block metering device VPB with directional solenoid valve, for further technical data † page 5, ig. 6 Technical Data Note Line sockets must be ordered separatly † page 10. For further technical data † basic design, page 5 Inlet thread connection Ambient temperature range Operating pressure max. Lubricant 2/2-directional solenoid valve Type Electrical connection Voltage Rated current Nominal output On-time Protection class Basic position Spherical seat valve Plug / DIN43650-AF3 24 V DC 0,67 A 16 W 100% ED (at max....
Open the catalog to page 7Order code Order code Block metering device Thread inlet and outlet screw connection M = M 10 x 1 G = G 1/8 Number of feeder sections 03 = for 3 sections (max. 6 outlets) 1) 04 = for 4 sections (max. 8 outlets) 05 = for 5 sections (max. 10 outlets) 06 = for 6 sections (max. 12 outlets) 07 = for 7 sections (max. 14 outlets) 08 = for 8 sections (max. 16 outlets) 09 = for 9 sections (max. 18 outlets) 10 = for 10 sections (max. 20 outlets) Number of occupied outlets 06 = 6 outlets open ... 20 = 20 outlets open Monitoring type 00 = without P 2 = Piston detector, 2-pin connection 2) P3 = Piston detector,...
Open the catalog to page 8Example of possible variations Example of possible variations Crossporting versions Example VPBM/VPBG for 1 to 6 lube points on one 3-section feeder Fig. 10 Variations Designation dual, with one outlet and check valve Designation triple, with one outlet and check valve Designation fourfold, with one outlet and check valve M10x1 = VPBM-C4 G1/8 = VPBG-C4 Designation dual, without outlet, without check valve 6 outlets Crossport, assembly position left right side Table 4 Crossports for connecting nearby outlets Number of connecting Outlets Order code for the complete crossport incl. hollow screws...
Open the catalog to page 9Accessories Check valves for the direct screw-in in a feeder outlet VPKG-RV 6 R1/8 tap. VPKM-RV-S4 6 M10×1 tap. for plug-in connector VPKG-RV4-VS 4 VPKG-RV-VS 6 VPKM-RV-VS 6 Order code Accessories Electrical Plug-in connectors Speciication Rectangular plug DIN EN 175301-803A, for 2/2-way-valve, 2-pin with splashed cable; 3 m, 3×0.75 mm2 Circular plug straight (A), Cable diameter 4–6 mm, 4-polig, max. 0.75 mm2 Circular plug straight (B), 4-pin with splashed cable; 5 m, 4×0.25 mm2 Order code Circular plug angled (C), Cable diameter 4–6 mm, 4-pin, max. 0.75 mm2 Circular plug angled (D), 4-pin with...
Open the catalog to page 10Spare parts Spare parts Designation Order code Piston detector, 2-pin Piston detector, 3-pin Corresponding O-ring 2/2-way valve, 24 V DC Cable socket - 2/2 way valve VPKM Screw connection G1/4 to M10×1 O-ring VPKG Screw connection G1/4 to G1/8
Open the catalog to page 11Important information on product usage SKF and Lincoln lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1 013 mbar) by more than 0,5 bar at their maximum permissible temperature. skf.com | skf.com/lubrication ® SKF is a registered trademark of the SKF Group. © SKF Group 2018 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken...
Open the catalog to page 128 Pages
4 Pages
8 Pages
4 Pages
24 Pages
8 Pages
16 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
8 Pages
4 Pages
8 Pages
8 Pages
18 Pages
4 Pages
8 Pages
8 Pages
36 Pages
20 Pages
20 Pages
8 Pages
8 Pages
6 Pages
12 Pages
4 Pages
2 Pages
4 Pages
4 Pages
15 Pages
2 Pages
2 Pages
12 Pages
30 Pages
12 Pages
2 Pages
16 Pages
8 Pages
2 Pages
2 Pages
24 Pages
28 Pages
8 Pages
4 Pages
4 Pages
4 Pages
2 Pages
12 Pages
4 Pages
2 Pages
12 Pages
4 Pages
8 Pages
12 Pages
2 Pages
4 Pages
6 Pages
16 Pages