Overview: The document provides detailed technical specifications and operational guidelines for the Flow Limiter SP/SMB13, designed for use in circulating-oil lubrication systems. It outlines the product's purpose, design, advantages, and operational procedures.
Specifications: The SP/SMB13 is a 2-way flow limiter valve with a volumetric flow check, suitable for line installation. It operates within an ambient temperature range of 0 to +70°C and is made from anodized aluminum alloy for corrosion resistance. The nominal volumetric flow can be adjusted from 6 to 38 l/min using interchangeable plug-in nozzles.
Design and Components: The flow limiter consists of a housing with a sensor, a regulating assembly with a control piston, plug-in nozzle, pressure spring, gear pair, and a cover with sight glass. The gear wheel-type flow indicator uses a Hall-Sensor to provide effective volumetric flow control.
Operation: The SP/SMB13 uses two restrictors in series to maintain constant volumetric flow, independent of system pressure and viscosity. The control piston adjusts the flow resistance to keep the differential pressure constant across the nonadjustable restrictor.
Advantages: Key benefits include reliable parallel distribution of flow, self-regulating metering, wide viscosity spectrum, easy system planning, simple start-up, and stable measuring procedures. An optional ATEX version is available for use in explosive environments.
Installation and Maintenance: The document provides detailed instructions for changing plug-in nozzles and emphasizes the importance of maintaining correct nozzle specifications on the rating plate. It also includes a table of nozzle sizes and corresponding order numbers.
Applications: The flow limiter is suitable for a broad range of applications, with a stable and reproducible measuring procedure. It is designed for use with mineral, synthetic, and eco-friendly oils within a lubricant temperature range of 0 to +90°C.
Ordering Information: Customers must specify the type designation and order number when purchasing. The document includes a key to order codes and an example of a type designation and order number.
Safety and Compliance: The document highlights the importance of using the product as intended and following all instructions. It also notes restrictions on the use of certain hazardous materials and provides contact information for SKF Lubrication Systems Germany GmbH.
See more

Catalog excerpts

SP/SMB13 product brochure-1

for line installation in circulating-oil lubrication systems. Flow limiters are used in circulating-oil lubrication systems. The task of a flow limiter is to divide up the volumetric flow of the main line into parallel individual volumetric flow quantities and to “limit” these according to requirements, or to keep them constant. The volumetric flow produced does not depend on the system pressure and is nearly independent of viscosity. Using interchangeable plug-in nozzles, the volumetric flow of the flow limiter SP/SMB13 can be set stepwise from 6 to 38 l/min. That makes it possible to adjust the volumetric flow rates at a later date. The SP/SMB 13 group comes with a visual/ electric gear wheel-type flow indicator that has a proportional factor of 39 ml per revolution. Advantages • reliable - Parallel distribution of individual flow quantities -Self-regulating metering, thus even volu metric flows for different back pressures. -Wide viscosity spectrum, practically independent of temperature and viscosity, thus stable system conditions. • simple start-up Preset volumetric flows allow short start-up times. • effective volumetric flow control by means of gear wheel-type flow indicator with Hall-Sensor • broad range of applications • easy system planning The required volumetric flow (the required flow limiter nozzle) has to be determined already during the project planning phase. • optional ATEX version • stable and reproducible measuring procedure, no corrective

 Open the catalog to page 1
SP/SMB13 product brochure-2

Dimension drawing The SP/SMB 13 flow limiter consists of the following: • Flow limiter housing (with sensor) flow limiter regulating assembly (with control piston, plug-in nozzle and pressure spring) • Gear pair • Flow limiter cover (with sight glass, seals, plugs and fastening screws) The housing, gears and cover consist of an anodized aluminum alloy to ensure corrosion-resistance and low weight. A round glass disk conforming to DIN 8902 (temperature stable pressed hard glass) is used for the sight-glass pane. The pane floats in the cover to avoid distortion and premature failure. The cover...

 Open the catalog to page 2
SP/SMB13 product brochure-3

System structure flow limiter The flow limiter SP/SMB 13 has two restrictors connected in series (D1, D2). Restrictor D1 involves an interchangeable plug-in nozzle, which as a nonadjustable restrictor defines the nominal volumetric flow. . The nonadjustable restrictor D1 is available in different nozzle sizes (refer to table on page 4). On the contrary, restrictor D2 is an adjustable restrictor, which has a different restrictor cross-section based on the position of the control piston RK. The flow resistance of restrictor D2 is automatically changed in such a manner by shifting the control piston...

 Open the catalog to page 3
SP/SMB13 product brochure-4

Technical Data Flow limiter General information Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . -way flow limiter valve with 2 volumetric flow check Application . . . . . . . . . . . . . . . . . . . . . . . for line installation Mounting position. . . . . . . . . . . . . . . . . . discretionary Ambient temperature range . . . . . . . . . 0 to + 70 °C Material. . . . . . . . . . . . . . . . . . . . . . . . . . AlCuPb F38, neutrally anodized Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . 2.4 kg Hydraulic Nominal volumetric flow . . . . . . . . . . . . tepwise from 6 to...

 Open the catalog to page 4
SP/SMB13 product brochure-5

Structure of the type designation for flow limiter ATEX ATEX = key is only for ATEX design (on request) Order example Code number of the nozzle size Nozzle index, see table page 4 Flow limiter, type SP/SMB and size 13 (SP/SMB13) outfitted with nozzle (2), with optical/electrical monitoring (gear wheel-type flow indicator) with Hall-Sensor, (E1), with a volumetric flow of 8 l/min and a nozzle diameter of 3 mm (nozzle index 300) results in the Type designation: SP/SMB13/2E1/300 and Order number: 24-2713-1300 Note The following flow limiters, type SP/SMB13, are available in ATEX design: Volumetric...

 Open the catalog to page 5
SP/SMB13 product brochure-6

Example of a circulating-oil lubrication system Example of a circulating-oil lubrication system Pump (1) delivers the lubricant to the main line (2). From the flow limiters arranged in parallel (3), the lubricant reaches the lubrication points directly. The pump's volumetric flow should be at least 15 % greater than the sum of nominal volumetric flows of all connected flow limiters. The pressure-regulating valve (4) integrated into the main line assumes the system pressure regulation. The gear wheel-type flow indicator (5) installed in the flow limiters (3) controls the volumetric flow. Display...

 Open the catalog to page 6
SP/SMB13 product brochure-7

Accessories/spare parts Accessories Designation Pulse meter with connection socket for PGA 3 Spare parts Designation Flow limiter SP/SMB13 without nozzle, with electrical monitoring Gasket set for SP/SMB 13 consisting of: Flat gasket D 32/45x05 O-ring 44x3 O-ring 90x3 Socket

 Open the catalog to page 7
SP/SMB13 product brochure-8

Order No. 1-3004-EN Subject to change without notice! (07/2014) Important product usage information All products from SKF may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed. Not all lubricants are suitable for use in centralized lubrication systems. SKF does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SKF lubrication systems or their components are not approved for use with gases, liquefied...

 Open the catalog to page 8

All SKF Lubrication Systems Germany GmbH catalogs and technical brochures

  1. 1154 flyer

    2  Pages

  2. LFC 5000

    4  Pages

  3. SSV-D

    2  Pages

  4. SL-V XL

    4  Pages

  5. HTL 429

    4  Pages

  6. Lincoln

    8  Pages

  7. AC FlowMaster

    12  Pages

  8. EOS

    2  Pages

  9. LFR Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.