Overview: The document details the PSG product series, modular feeders for SKF ProFlex and SKF CircOil lubrication systems, suitable for oil and grease applications in machinery such as metal-forming, tunnel boring, and paper machinery.
Fields of Application: Applicable in metal-forming, tunnel boring, paper machinery, and general mechanical engineering.
Advantages: Key benefits include easy servicing, flexibility with replaceable metering sections, expandability with additional components, efficient operation, and enhanced monitoring. Available in three sizes, they offer different flow rates and increased reliability due to integrated check valves.
Product Specifications: The PSG series includes models PSG1, PSG2, and PSG3 with maximum inlet volumes of 0.8, 2.5, and 6.0 l/min, respectively. They support various monitoring and attachment options, with corrosion-resistant designs for PSG2 and PSG3.
Design and Operation: Featuring a modular design, the feeders have replaceable metering sections on a common baseplate. Pistons meter lubricant to outlets in a predetermined ratio, with monitoring through indicators and detectors.
Monitoring and Attachments: Equipped with flow limiters, controllers, and solenoid valves, monitoring options include gear-type flow indicators, cycle indicators, and proximity switches.
Technical Data: Detailed specifications include dimensions, weight, material composition, operating pressure, and temperature range. Feeders are hydraulically controlled and mountable in any position.
Important Usage Information: SKF and Lincoln systems are not approved for certain gases and high vapor pressure fluids. Installation and operation guidelines ensure optimal performance.
Specifications: Baseplates are aluminum alloy, sections are galvanized steel, and seals are FKM. Maximum operating pressure is 200 bar, with inlet flow up to 2.5 l/min for PSG2 and 6 l/min for PSG3. Compatible with various oils and greases.
Procedures and Monitoring: Installation requires piston positioning at a 90° angle to machine force. Monitoring includes piston detectors, cycle indicators, and solenoid valves. Electrical components have a rated voltage of 10 to 36 V DC, with protection classes IP65 or IP67.
Technical Data: PSG2 features a 4-point LED design, max load current of 100 mA, and weight of 0.12 kg for the piston detector. PSG3 offers additional options for solenoid valves and flow controllers.
Recommendations: Ensure proper alignment and installation, and regularly monitor and maintain the system for optimal performance.
Installation and Retrofitting: Instructions for retrofitting cycle indicators and selecting frame size, monitoring options, and attachments are provided for customization.
Order and Configuration: Guidelines for selecting frame sizes, monitoring options, and attachments are included, with recommendations to use Cadenas for configuration and obtaining drawings and order codes.
See more

Catalog excerpts

PSG product brochure-1

Modular feeder PSG product series For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems Metal-forming machinery (presses) Tunnel boring machinery Paper machinery General mechanical engineering applications Advantages • Easy to service thanks to outlets located in the baseplate; tubes do not need to be removed during repair work; between 1 and 20 outlets • Flexible due to replaceable metering sections • Expandable by attaching flow limiters, flow controllers, gear-type flow indicators, and directional solenoid valves.Efficient due to low pressure loss • Can be monitored using piston detectors or visual cycle indicators • Adjustable by consolidating outlets internally and externally • 3 sizes for ranges up to 0.8, 2.5, and 6 l/min • Increased functional reliability due to check valve installed standard (PSG2 and PSG3) • Increased metering accuracy due to placement of integrated check valves immediately following metering piston (PSG2 and PSG3) • Increased corrosion resistance due to special design with anodized baseplate and chemically nickel-plated sections (basi

 Open the catalog to page 1
PSG product brochure-2

PSG product series Excerpt from product overview PSG1 Basic design Basic design Piston detector Piston detector Piston detector Visual cycle indicator Proximity switch Gear-type flow indicator Visual cycle indicator with housing (for attaching a sensor provided by customer) Directional solenoid valve Flow controller Basic design

 Open the catalog to page 2
PSG product brochure-3

PSG product series Product overview Product selection Product series Max. inlet volume Lubricant flow1)2) Oil Grease [l/min] Supported attachments Cycle Cycle Piston indicator indicator Proximity detector optical with housing switch Flow Flow controller limiter Gear-type type flow indicator Directional solenoid valve 4/2 2/2 Page Depending on the number and size of metering pistons. Other inlet volumes available on request. Corrosion-resistant design available on request. Overview of inlet volumes Max. inlet volumes [l/min] 1) 7 6.0 6 On feeder configuration with largest piston capacity Important...

 Open the catalog to page 3
PSG product brochure-4

PSG product series Product description Operation († Figure 1) Observation of the movements begin the moment that all three pistons (A, B, C) on the left end stop show that the lubricant and operating pressures reach from the inlet through the through-duct in the middle to the pistons C-right, B-right and A-left; that is, while pistons C and B retain their positions, the A piston is pushed right. The lubricant volume specified by the piston diameter and stroke is pressed into a duct on the end (outlet 4) the same quantity exits. This stroke movement of piston A opens or closes multiple control...

 Open the catalog to page 4
PSG product brochure-5

PSG product series Monitoring and attachments Monitoring All standard sections can be monitored directly or retrofitted with a piston detector. However, if the piston movement will be monitored by a cycle indicator (visual stroke monitoring) or a proximity switch, the appropriate sections must be used. The modular structure of the modular feeders is particularly apparent in the range of available attachments. Depending on frame size, it can be equipped with the following upstream equipment: • Flow limiter • Flow controller • 4/2-directional solenoid valve • 2/2-directional solenoid valve If the...

 Open the catalog to page 5
PSG product brochure-6

PSG1 Modular Feeder Basic design for oil and grease Technical Data Type . . . . . . . . . . . . . Mounting position . . . . . . Ambient temperature range . Baseplate with . . . . . . . . Tightening torque feeder section . . . . Material Baseplate . . . . . . . . . . . . . . . . Sections . . . . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . . . . . Hydraulic system Operating pressure, max. . . . . . . . . Inlet volumetric flow . . . . . . . . . . . Volume per outlet and cycle3) . . . . . . Division ratio . . . . . . . . . . . . . . . Pressure loss with oil . . . . . . . . . . Lubricant...

 Open the catalog to page 6
PSG product brochure-7

PSG1 Modular Feeder Monitoring via piston detector, 3-pin, M12x1 plug and cycle indicator for oil and grease Technical Data With piston detector, 3-pin Basic design † see Technical Data, page 6 Piston detector, electrical 1) Ambient temperature range . Operating pressure, max. . . Weight . . . . . . . . . . . . Design . . . . . . . . . . . . Rated voltage . . . . . . . . Residual ripple . . . . . . . . Max. load current . . . . . . Protection class . . . . . . . Outlet function . . . . . . . . Cycle indicator, visual 2) Ambient temperature range . . . . . . . Operating pressure, max. . . . ....

 Open the catalog to page 7
PSG product brochure-8

PSG1 Modular Feeder Monitoring via proximity switch and visual cycle indicator with housing for oil and grease Technical Data With with proximity switch PSG1proximity switch Basic design † Technical Data, page 6 Proximity switch M12×1, electrical Ambient temperature range . . . . . Operating pressure, max. . . . . . . Weight . . . . . . . . . . . . . . . . Design . . . . . . . . . . . . . . . . Rated voltage . . . . . . . . . . . . Max. load current . . . . . . . . . . Protection class . . . . . . . . . . . Outlet function . . . . . . . . . . . . Cycle indicator with housing 1)2) Ambient temperature...

 Open the catalog to page 8
PSG product brochure-9

PSG2 Modular Feeder Basic design for oil and grease Technical Data Type . . . . . . . . . . . . . Mounting position . . . . . . Ambient temperature range . Baseplate with . . . . . . . . Tightening torque feeder section . . . . Material Baseplate . . . . . . . . . . . . . . . . Sections . . . . . . . . . . . . . . . . . Seals . . . . . . . . . . . . . . . . . . . Hydraulic system Operating pressure, max. . . . . . . . . Inlet volumetric flow . . . . . . . . . . . Volume per outlet and cycle3) . . . . . . Division ratio . . . . . . . . . . . . . . . Pressure loss with oil . . . . . . . . . . Lubricant...

 Open the catalog to page 9
PSG product brochure-10

PSG2 Modular Feeder Monitoring via piston detector, 3-pin, M12x1 plug and cycle indicator for oil and grease Technical Data With piston detector Basic design † Technical Data, page 9 Piston detector, electrical 1) Ambient temperature range . Operating pressure, max. . . Weight . . . . . . . . . . . . Design . . . . . . . . . . . . Rated voltage . . . . . . . . Residual ripple . . . . . . . . Max. load current . . . . . . Protection class . . . . . . . Outlet function . . . . . . . . Cycle indicator, visual 2) Ambient temperature range . . . . . . . Operating pressure, max. . . . . . . . . Weight...

 Open the catalog to page 10

All SKF Lubrication Systems Germany GmbH catalogs and technical brochures

  1. 1154 flyer

    2  Pages

  2. LFC 5000

    4  Pages

  3. SSV-D

    2  Pages

  4. SL-V XL

    4  Pages

  5. HTL 429

    4  Pages

  6. Lincoln

    8  Pages

  7. AC FlowMaster

    12  Pages

  8. EOS

    2  Pages

  9. LFR Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.