Product series 143 brochure

Product series 143 brochure
1 / 24 PagesView full catalog

Product series 143 brochure

Product catalog summary
Overview: The SKF Gerotor Pumps, Product Series 143, are designed for SKF CircOil centralized lubrication systems, suitable for circulating-oil and total-loss lubrication systems in industries like mechanical engineering, shipbuilding, and heavy industries.
Specifications:
  • Delivery Range: 0.85 to 50 l/min at pressures up to 50 bar.
  • Viscosity Range: 20 to 1000 mm²/s for mineral and synthetic oils.
  • Temperature: Operates in ambient temperatures from 0 to +40°C and medium temperatures from 0 to +80°C.
  • Noise Level: 60 dBA.
  • Designs: Available in NBR and FKM with squirrel cage motors for 50 and 60 Hz.
Advantages:
  • High efficiency with low flow pulsation.
  • Good suction due to cycloid contour.
  • Compact and modular design.
Applications: Used in lubrication systems for bearings and friction points in industries such as shipbuilding, offshore, paper, and heavy industries.
Technical Data:
  • Operating Pressure: Up to 50 bar.
  • Drive Speed: 1400 and 2800 min-1.
  • Protection Class: IP 54.
  • Materials: Hydraulic cast housing, sintered gerotor, steel shafts, SKF bearing.
Installation: Can be installed horizontally or vertically with foot or flange versions.
Ordering Information: Order codes include model design, sealing design, and motor specifications.
Additional Notes: Ensure correct pump rotation and use pressure-regulating valves. Filters with a minimum purity class of 20/17/14 are recommended.
Motor Specifications: Motors meet temperature class 130 (B) with a coolant temperature of 40°C, providing a power reserve of +10% and a temperature reserve of +20 K. Protection class IP55 ensures dust and water jet protection.
Terminal Box: Protection class IP55, standard location on the right side, rotatable by 90°.
Rating Plates: Include detailed motor information such as type, voltage, frequency, and efficiency.
Voltage Codes: Motors ≥0.75 kW must be IE3 efficiency class.
Technical Data: Designed for -20 to +40 °C and up to 1000 m altitude, with surface cooling and no temperature monitoring.
Viscosity-Temperature Relationship: Diagram shows significant viscosity changes at lower temperatures.
Spare Parts: Exploded view and order numbers for components provided.
Gerotor Pump Series 143: Comparison of old and new order numbers, detailing delivery rates, back pressure, and viscosity ranges.
Important Usage Information: Not approved for use with gases or fluids with high vapor pressure.
Legal and Trademark Information: Includes trademark and copyright notices, requiring written permission for reproduction.
See more

Catalog excerpts

Product series 143 brochure-1

Gerotor Pumps Product series 143 For oil, for use in SKF CircOil centralized lubrication systems

 Open the catalog to page 1
Product series 143 brochure-2

Gerotor pumps, product series 143 SKF gerotor pump units of product series 143 are self-priming positive-displacement pumps with fixed displacement and high efficiency. They are used in SKF CircOil centralized lubrication systems for a variety of tasks and applications, especially in circulating-oil and total-loss lubrication systems. General mechanical and plant engineering Shipbuilding and offshore industry Paper, printing, and pulp industries Heavy industry Advantages: • Flexible delivery range from 0.85 to 50 l/min at system pressures up to 50 bar • Large viscosity range for standard mineral...

 Open the catalog to page 2
Product series 143 brochure-3

Gerotor pumps, product series 143 Illustration of designs and accessories Gerotor pump unit in foot design Gerotor pump unit in flange design Gerotor pump Pump flange Shaft coupling ICE squirrel cage motor Gerotor pump+pump flange+ shaft coupling

 Open the catalog to page 3
Product series 143 brochure-4

Gerotor pumps, product series 143 Fundamentals General use Delivery rates and characteristic curves SKF gerotor pump units of product series 143 are used in circulating-oil and total-loss lubrication systems in a flow rate range of 0.85 to 50 l/min. The standard permissible ambient temperature is between 0 and +40 °C. Higher ambient temperatures are possible, though they lead to a reduction in motor performance and thus the delivery rate. The permissible temperature of the pumped medium is between 0 and +80°C. The gerotor pumps are available in NBR and FKM designs. SKF gerotor pump units feed...

 Open the catalog to page 4
Product series 143 brochure-5

Gerotor pumps, product series 143 Fundamentals Design (→ Figure 1) SKF gerotor pump units of product series 143 have a constant displacement volume and one delivery circuit. The annular-toothed feeding element, also referred to as the gerotor, is equipped with a cycloid contour, which creates a large tooth meshing length. This yields a low volumetric flow pulsation and thus very smooth running, low noise production, and good suction characteristics. SKF gerotor pumps consist primarily of pump housing (1), the shaft (2), the displacement elements toothed rotor (3) and annular gear (4), and the...

 Open the catalog to page 5
Product series 143 brochure-6

Gerotor pumps, product series 143 Technical data Table 1 Gerotor pump unit in foot design Technical data Lubricant Operating viscosity standard mineral, synthetic lubricating and hydraulic oils 20–1000 mm2/s Flow range Operating pressure Ambient temperature range Medium temperature range Protection class acc. to DIN EN 60529 Operating noise level Drive speed depending on design Suction head, max. Varnishing Duty type per VDE 0530 Sealing material Mounting position Materials Pump housing Gerotor pump unit in flange design Gerotor insert Shafts Bearing hydraulic cast (pressure-proof) with good...

 Open the catalog to page 6
Product series 143 brochure-7

Gerotor pumps, product series 143 Order code Product series 143 Model design 1 = Motor in foot design (IMB34) 2 = Motor in flange design (IMB14) 3 = Gerotor pump+pump flange+shaft coupling (without motor) 4 = Only gerotor pump (without motor) 1) Sealing design F = FKM Code for pump design 1) † Table 2 Terminal box position 2) as seen from shaft extension of drive side R = Right O = Top X = On motor in flange design (IMB14), Terminal box position on suction port side of pump Motor certification 2) (others on request) A = CE (Europe) Voltage code 2) † page 16 2) Not applicable on designs without...

 Open the catalog to page 7
Product series 143 brochure-8

Gerotor pumps, product series 143 Gerotor pump design, technical data and dimensions Figure 2 Gerotor pump Fig. 1 Shaft extension 1) For securing the coupling boss in axial direction. Gerotor pump († Figure 2) Niminal delivery rate [l/min] Back Perm. pressure viscosity max. range [bar] [mm2/s] Required Char. Nominal drive Suction curve output Speed power port No. 1) [cm3/rev.] [min–1] [kW] S

 Open the catalog to page 8
Product series 143 brochure-9

Gerotor pumps, product series 143 Gerotor pump+pump flange+shaft coupling design, technical data and dimensions Figure 3 Gerotor pump + pump flange Coupling assembly ∅SD/PD ∅S/P Pump with mounting plate 3) Motor connection 3) Mounting plate only for delivery rate 30, 40, and 50 l/min. T 4) Supplied detached, tightening torque for M6 = 10 Nm±2Nm; for M8 = 18 Nm±2Nm; for M10 = 30 Nm±2Nm Table 3 Gerotor pump + pump flange († Figure 3) Design N (NBR) / F (FKM) Order No. 5) Coupling assembly († Firgure 4) Motor connection († Figure 5) M68 tief M812 tief M812 tief M812 tief M812 tief M813 tief M812...

 Open the catalog to page 9
Product series 143 brochure-10

Gerotor pumps, product series 143 Foot and flange designs, technical data and dimensions Figure 6 Foot design (type IMB34) max. XB Delivery Back Viscosity rate pres- range sure max. Char. Food design curve N (NBR) / No. 1) F (FKM) Order No. 2)3) Nominal Suctionoutput port Pressure port Flange design N (NBR) / F (FKM) Order No. 2)3) 1) † see page 12 2) Supplement the order No. with the code letter for the desired seal design. Seal design NBR (N) or FKM (F). 3) Sup

 Open the catalog to page 10
Product series 143 brochure-11

Gerotor pumps, product series 143 Foot and flange designs, technical data and dimensions Figure 7 Flange design (type IMB14) 1) Mounting plate only for delivery rate 30, 40 and 50 l/min. Table 4 Dimensions [mm] († Drawing 6+7)

 Open the catalog to page 11
Product series 143 brochure-12

Gerotor pumps, product series 143 Characteristic curves Chart 1 Delivery rate Q [l/min] Delivery rate Q [l/min] 10 Legend to diagrams 1–4: Characteristic curve 1: 0.85 l/min Characteristic curve 2: 1.7 l/min Characteristic curve 3: 2.5 l/min Characteristic curve 4: 5.25 l/min Characteristic curve 5: 9 l/min Characteristic curve 6: 12.5 l/min Characteristic curve 7: 19 l/min Characteristic curve 8: 30 l/min Characteristic curve 9: 40 l/min Characteristic curve 10: 50 l/min Tolerances: VDMA 24284-II For connection with a frequency of 60 Hz, the speed and the volumetric flow are increased by 20%...

 Open the catalog to page 12
Product series 143 brochure-13

Gerotor pumps, product series 143 Characteristic curves Chart 3 Operating viscosity 750 mm2/s, 50 Hz Chart 4 Operating viscosity 1000 mm2/s, 50 Hz Delivery rate Q [l/min] Delivery rate Q [l/min] 10 Legend to diagrams 1–4: Characteristic curve 1: 0.85 l/min Characteristic curve 2: 1.7 l/min Characteristic curve 3: 2.5 l/min Characteristic curve 4: 5.25 l/min Characteristic curve 5: 9 l/min Characteristic curve 6: 12.5 l/min Characteristic curve 7: 19 l/min Characteristic curve 8: 30 l/min Characteristic curve 9: 40 l/min Characteristic curve 10: 50 l/min For connection with a frequency of 60 Hz,...

 Open the catalog to page 13

All SKF Lubrication Systems Germany GmbH catalogs and technical brochures

  1. 1154 flyer

    2  Pages

  2. LFC 5000

    4  Pages

  3. SSV-D

    2  Pages

  4. SL-V XL

    4  Pages

  5. HTL 429

    4  Pages

  6. Lincoln

    8  Pages

  7. AC FlowMaster

    12  Pages

  8. EOS

    2  Pages

  9. LFR Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.