Electrically operated compact pump ECP Reliable and adaptable pump for single-line lubrication systems
Open the catalog to page 1Product information 1,7 liter Filling strainer prevents dirt from entering when filling Mounting plate with six optional mounting bores for max. installation flexibilities Fill-level monitoring also for cartridges Fill-level monitor with pre-warning functionality Power connection and connection to PLC Venting screw for simple venting during system start-up or after cartridge exchange Manual lubrication push button for easy system start-up or venting Two quick connector fitting lubricant outlets for up to 12 cm3/min Description The electrically driven compact pump ECP for oil and fluid grease...
Open the catalog to page 2Minimum mounting dimensions: Height: A-1 = 440 mm A-2 = pump height plus 100 mm Width: B = 240 mm Depth: C = 210 mm Control and monitoring options The ECP works independently of the reservoir used with 24 V DC and can easily be integrated into any existing machine control system (PLC). Controlled lubrication intervals, lubricant quantities and level reports are no problem. In addition, the pump is capable of manually activating a lubrication cycle. An easy-to-access venting screw enables simple installation and operational start-up. With an ECP pump based lubrication system and a few lubricant...
Open the catalog to page 3Order information identification code Pump type_ Electric Compact Pump Delivery volume_ Warning switch for minimum filling level_ W = Warning level (pre-warning empty) * 0 = No warning switch Wall bracket_ A = With standard bracket 0 = Without Electric connection_ A = Square plug according to DIN EN 175301-803-A Main-line connection_ 1 = Connection thread M10x1 2 = Quick connector for tube 06 mm 3 = Banjo quick connector for tube 06 mm 4 = Quick connector for tube 08 mm X = Closed Cartridge or reservior version_ 00000 = without cartridge F00138 = 380 ml cartridge (prefilled with Zeller+Gmelin...
Open the catalog to page 4Main-line connectors Pre-filled standard cartridges Order number Designation Conntection Order number Lubricant 1) Package Castrol Tribol GR 3020/1000-000 PD 2) 10 pcs Castrol Tribol GR 3020/1000-000 PD 3) 10 pcs Zeller Gmelin Divinol Lithogrease 00 1 10 pcs Electrical connectors 1) Further lubricants on request Order number Designation 2) 120 ml 0,5 liter reservoir, spare part kit 1,0 liter reservoir, spare part kit 1,7 liter reservoir, spare part kit Main-line pressure-relief valves Order number Designation Tube0 levelswitch kit, fluid grease levelswitch kit, oil filling strainer operating...
Open the catalog to page 5340 metering devices Offered in two-, three- and five-port models, series 340 metering devices were developed for use with single-line, centralized lubrication systems for oil and fluid grease. These metering devices are designed for installation directly on the machine/system requiring lubrication. • 0,01 to 0,16 cm3 metering quantity (oil) • Designed for installation directly on the machine/system requiring lubrication • Select optional push-in or screw-in type metering nipples for feed line connections • Choose optional push-in or screw-in type main line fittings 341 metering devices Developed...
Open the catalog to page 6Quick connector fittings SKF quick connectors are the faster alternative when it comes to connecting pipes Push-in type connectors are available for fast establishment of secure connections Simply plug the end of the line into the pre-installed connector - all done! No wrench is required Connections can be made more easily and quickly, especially in difficult-to-access areas Push-in type fittings can be used to connect the entire system of lines from the pump to the metering devices, pressure switches, etc - all the way to the lubrication points. • Fast and virtually leakage-free connection •...
Open the catalog to page 7Choose the right lubricant for your application SKF single-line systems are available for all types of lubricants: oil, fluid and hard grease. Selecting the right lubricant for your application can be a differentiator in terms of productivity and environmental impact. The ECP and 340/341 metering devices are designed for use with either oil or fluid grease. Both lubricant types prevent crush and excessive abrasion on linear guides or bearings. Oil Oils are measured in viscosity. The viscosity is an expression of a fluid's internal friction. Oils are classified in ISO VG viscosity classes from...
Open the catalog to page 88 Pages
4 Pages
4 Pages
24 Pages
8 Pages
16 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
8 Pages
4 Pages
8 Pages
8 Pages
18 Pages
4 Pages
8 Pages
8 Pages
36 Pages
20 Pages
20 Pages
12 Pages
8 Pages
8 Pages
6 Pages
12 Pages
4 Pages
2 Pages
4 Pages
4 Pages
15 Pages
2 Pages
2 Pages
12 Pages
30 Pages
12 Pages
2 Pages
16 Pages
8 Pages
2 Pages
2 Pages
24 Pages
28 Pages
8 Pages
4 Pages
4 Pages
4 Pages
2 Pages
12 Pages
4 Pages
2 Pages
12 Pages
4 Pages
8 Pages
12 Pages
2 Pages
4 Pages
6 Pages
16 Pages