SP/SMB14 product brochure
8Pages

{{requestButtons}}

Catalog excerpts

SP/SMB14 product brochure - 1

Flow limiter SP/SMB14 for line installation in circulating-oil lubrication systems. Flow limiters are used in circulating-oil lubrication systems. The task of a flow limiter is to divide up the volumetric flow of the main line into parallel individual volumetric flow quantities and to “limit” these according to requirements, or to keep them constant. The volumetric flow produced does not depend on the system pressure and is nearly independent of viscosity. Using interchangeable plug-in nozzles, the volumetric flow of the flow limiter SP/SMB14 can be set stepwise from 25 to 90 l/min. That makes it possible to adjust the volumetric flow rates at a later date. The SP/SMB14 group comes with a visual/ electric gear wheel-type flow indicator that has a proportional factor of 106 ml per revolution. Advantages • reliable - Parallel distribution of individual flow quantities - Self-regulating metering, thus even volumetric flows for different back pressures - Wide viscosity spectrum, practically independent of temperature and viscosity, thus stable system conditions. • easy system planning The required volumetric flow (the required flow limiter nozzle) has to be determined already during the project planning phase. • simple start-up Preset volumetric flows allow short start-up times. • effective volumetric flow control by means of gear wheel-type flow indicator with Hall-Sensor • broad range of applications • optional ATEX version • stable and reproducible measuring procedure, no corrective

Open the catalog to page 1
SP/SMB14 product brochure - 2

Dimension drawing The SP/SMB14 flow limiter consists of the following: • Flow limiter housing (with sensor) flow limiter regulating assembly (with control piston, plug-in nozzle and pressure spring) • Gear pair • Flow limiter cover (with sight glass, seals, plugs and fastening screws). The housing, gears and cover consist of an anodized aluminum alloy thats results in corrosion-resistance and low weight. A round glass disk conforming to DIN 8902 (temperature stable pressed hard glass) is used for the sight-glass pane. The pane floats in the cover to avoid distortion and premature failure....

Open the catalog to page 2
SP/SMB14 product brochure - 3

System structure flow limiter The flow limiter SP/SMB14 has two restrictors connected in series (D1, D2). Restrictor D1 involves an interchangeable plug-in nozzle, which as a nonadjustable restrictor defines the nominal volumetric flow. . The nonadjustable restrictor D1 is available in different nozzle sizes (refer to table on page 4). On the contrary, restrictor D2 is an adjustable restrictor, which has a different restrictor cross-section based on the position of the control piston RK. The flow resistance of restrictor D2 is automatically changed in such a manner by shifting the control...

Open the catalog to page 3
SP/SMB14 product brochure - 4

Technical Data Flow limiter General information Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-way flow limiter valve with volumetric flow check Application . . . . . . . . . . . . . . . . . . . . . . . . for line installation Mounting position . . . . . . . . . . . . . . . . . . any Ambient temperature range . . . . . . . . . . . 0 to +70 °C Material . . . . . . . . . . . . . . . . . . . . . . . . . . . AlCuPb F38, neutrally anodized Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.8 kg Hydraulic Nominal volumetric flow. . . . . . . . . . . . . . stepwise...

Open the catalog to page 4
SP/SMB14 product brochure - 5

Order example Flow limiter, type SP/SMB and size 14 (SP/SMB14) outfitted with nozzle (2), with optical/electrical monitoring (gear wheel-type flow indicator) with Hall-Sensor (E1), with a volumetric flow of 65 l/min and a nozzle diameter of 9.6 mm (nozzle index 960) gives the Type designation: SP/SMB14/2E1/960 and Order number: 24-2714-4960 Structure of the type designation for flow limiter ATEX = key is only for ATEX design (on request) Code number of the nozzle size Nozzle index, see table on page 4 Volumetric flow control /0 = without electrical monitoring E1 = with optical/electrical...

Open the catalog to page 5
SP/SMB14 product brochure - 6

Example of a circulating-oil lubrication system Example of a circulating-oil lubrication system Pump (1) delivers the lubricant to the main line (2). From the flow limiters arranged in parallel (3), the lubricant reaches the lubrication points directly. The pump's volumetric flow should be at least 15 % greater than the sum of nominal volumetric flows of all connected flow limiters. The pressure-regulating valve integrated into the main line (4) assumes the system pressure regulation. The gear wheel-type flow indicator (5) integrated in the flow limiters (3) controls the volumetric flow....

Open the catalog to page 6
SP/SMB14 product brochure - 7

Accessories/spare parts Accessories Designation Pulse meterwith connection socket for PGA 3 Spare parts Designation Flow limiter SP/SMB14 without nozzle, with electrical monitoring Gasket set for SP/SMB 14 consisting of: Flat gasket D 32/45x0.5 O-ring 44x3 O-ring 90x3

Open the catalog to page 7
SP/SMB14 product brochure - 8

Order No. 1-3005-EN Subject to change without notice! (10/2021) Important product usage information All products from SKF may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed. Not all lubricants are suitable for use in centralized lubrication systems. SKF does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SKF lubrication systems or their components are not approved for use with gases,...

Open the catalog to page 8

All SKF Lincoln Automatic Lubrication Systems catalogs and technical brochures

  1. 1154 flyer

    2 Pages

  2. LFC 5000

    4 Pages

  3. SSV-D

    2 Pages

  4. SL-V XL

    4 Pages

  5. HTL 429

    4 Pages

  6. Lincoln

    8 Pages

  7. AC FlowMaster

    12 Pages

  8. EOS

    2 Pages

  9. LFR Series

    4 Pages