Product series 143 brochure
24Pages

{{requestButtons}}

Catalog excerpts

Product series 143 brochure - 1

Gerotor Pumps Product series 143 For oil, for use in SKF CircOil centralized lubrication systems

Open the catalog to page 1
Product series 143 brochure - 2

Gerotor pumps, product series 143 SKF gerotor pump units of product series 143 are self-priming positive-displacement pumps with fixed displacement and high efficiency. They are used in SKF CircOil centralized lubrication systems for a variety of tasks and applications, especially in circulating-oil and total-loss lubrication systems. General mechanical and plant engineering Shipbuilding and offshore industry Paper, printing, and pulp industries Heavy industry Advantages: • Flexible delivery range from 0.85 to 50 l/min at system pressures up to 50 bar • Large viscosity range for standard...

Open the catalog to page 2
Product series 143 brochure - 3

Gerotor pumps, product series 143 Illustration of designs and accessories Gerotor pump unit in foot design Gerotor pump unit in flange design Gerotor pump Pump flange Shaft coupling ICE squirrel cage motor Gerotor pump+pump flange+ shaft coupling

Open the catalog to page 3
Product series 143 brochure - 4

Gerotor pumps, product series 143 Fundamentals General use Delivery rates and characteristic curves SKF gerotor pump units of product series 143 are used in circulating-oil and total-loss lubrication systems in a flow rate range of 0.85 to 50 l/min. The standard permissible ambient temperature is between 0 and +40 °C. Higher ambient temperatures are possible, though they lead to a reduction in motor performance and thus the delivery rate. The permissible temperature of the pumped medium is between 0 and +80°C. The gerotor pumps are available in NBR and FKM designs. SKF gerotor pump units...

Open the catalog to page 4
Product series 143 brochure - 5

Gerotor pumps, product series 143 Fundamentals Design (→ Figure 1) SKF gerotor pump units of product series 143 have a constant displacement volume and one delivery circuit. The annular-toothed feeding element, also referred to as the gerotor, is equipped with a cycloid contour, which creates a large tooth meshing length. This yields a low volumetric flow pulsation and thus very smooth running, low noise production, and good suction characteristics. SKF gerotor pumps consist primarily of pump housing (1), the shaft (2), the displacement elements toothed rotor (3) and annular gear (4), and...

Open the catalog to page 5
Product series 143 brochure - 6

Gerotor pumps, product series 143 Technical data Table 1 Gerotor pump unit in foot design Technical data Lubricant Operating viscosity standard mineral, synthetic lubricating and hydraulic oils 20–1000 mm2/s Flow range Operating pressure Ambient temperature range Medium temperature range Protection class acc. to DIN EN 60529 Operating noise level Drive speed depending on design Suction head, max. Varnishing Duty type per VDE 0530 Sealing material Mounting position Materials Pump housing Gerotor pump unit in flange design Gerotor insert Shafts Bearing hydraulic cast (pressure-proof) with...

Open the catalog to page 6
Product series 143 brochure - 7

Gerotor pumps, product series 143 Order code Product series 143 Model design 1 = Motor in foot design (IMB34) 2 = Motor in flange design (IMB14) 3 = Gerotor pump+pump flange+shaft coupling (without motor) 4 = Only gerotor pump (without motor) 1) Sealing design F = FKM Code for pump design 1) † Table 2 Terminal box position 2) as seen from shaft extension of drive side R = Right O = Top X = On motor in flange design (IMB14), Terminal box position on suction port side of pump Motor certification 2) (others on request) A = CE (Europe) Voltage code 2) † page 16 2) Not applicable on designs...

Open the catalog to page 7
Product series 143 brochure - 8

Gerotor pumps, product series 143 Gerotor pump design, technical data and dimensions Figure 2 Gerotor pump Fig. 1 Shaft extension 1) For securing the coupling boss in axial direction. Gerotor pump († Figure 2) Niminal delivery rate [l/min] Back Perm. pressure viscosity max. range [bar] [mm2/s] Required Char. Nominal drive Suction curve output Speed power port No. 1) [cm3/rev.] [min–1] [kW] S

Open the catalog to page 8
Product series 143 brochure - 9

Gerotor pumps, product series 143 Gerotor pump+pump flange+shaft coupling design, technical data and dimensions Figure 3 Gerotor pump + pump flange Coupling assembly ∅SD/PD ∅S/P Pump with mounting plate 3) Motor connection 3) Mounting plate only for delivery rate 30, 40, and 50 l/min. T 4) Supplied detached, tightening torque for M6 = 10 Nm±2Nm; for M8 = 18 Nm±2Nm; for M10 = 30 Nm±2Nm Table 3 Gerotor pump + pump flange († Figure 3) Design N (NBR) / F (FKM) Order No. 5) Coupling assembly († Firgure 4) Motor connection († Figure 5) M68 tief M812 tief M812 tief M812 tief M812 tief M813 tief...

Open the catalog to page 9
Product series 143 brochure - 10

Gerotor pumps, product series 143 Foot and flange designs, technical data and dimensions Figure 6 Foot design (type IMB34) max. XB Delivery Back Viscosity rate pres- range sure max. Char. Food design curve N (NBR) / No. 1) F (FKM) Order No. 2)3) Nominal Suctionoutput port Pressure port Flange design N (NBR) / F (FKM) Order No. 2)3) 1) † see page 12 2) Supplement the order No. with the code letter for the desired seal design. Seal design NBR (N) or FKM (F). 3) Sup

Open the catalog to page 10
Product series 143 brochure - 11

Gerotor pumps, product series 143 Foot and flange designs, technical data and dimensions Figure 7 Flange design (type IMB14) 1) Mounting plate only for delivery rate 30, 40 and 50 l/min. Table 4 Dimensions [mm] († Drawing 6+7)

Open the catalog to page 11
Product series 143 brochure - 12

Gerotor pumps, product series 143 Characteristic curves Chart 1 Delivery rate Q [l/min] Delivery rate Q [l/min] 10 Legend to diagrams 1–4: Characteristic curve 1: 0.85 l/min Characteristic curve 2: 1.7 l/min Characteristic curve 3: 2.5 l/min Characteristic curve 4: 5.25 l/min Characteristic curve 5: 9 l/min Characteristic curve 6: 12.5 l/min Characteristic curve 7: 19 l/min Characteristic curve 8: 30 l/min Characteristic curve 9: 40 l/min Characteristic curve 10: 50 l/min Tolerances: VDMA 24284-II For connection with a frequency of 60 Hz, the speed and the volumetric flow are increased by...

Open the catalog to page 12
Product series 143 brochure - 13

Gerotor pumps, product series 143 Characteristic curves Chart 3 Operating viscosity 750 mm2/s, 50 Hz Chart 4 Operating viscosity 1000 mm2/s, 50 Hz Delivery rate Q [l/min] Delivery rate Q [l/min] 10 Legend to diagrams 1–4: Characteristic curve 1: 0.85 l/min Characteristic curve 2: 1.7 l/min Characteristic curve 3: 2.5 l/min Characteristic curve 4: 5.25 l/min Characteristic curve 5: 9 l/min Characteristic curve 6: 12.5 l/min Characteristic curve 7: 19 l/min Characteristic curve 8: 30 l/min Characteristic curve 9: 40 l/min Characteristic curve 10: 50 l/min For connection with a frequency of 60...

Open the catalog to page 13

All SKF Lincoln Automatic Lubrication Systems catalogs and technical brochures

  1. 1154 flyer

    2 Pages

  2. LFC 5000

    4 Pages

  3. SSV-D

    2 Pages

  4. SL-V XL

    4 Pages

  5. HTL 429

    4 Pages

  6. Lincoln

    8 Pages

  7. AC FlowMaster

    12 Pages

  8. EOS

    2 Pages

  9. LFR Series

    4 Pages