Gear Pump Units For single-line centralized lubrication systems These units comprising the MFE Group are designed to supply the lubricant used in intermittently operated, single-line centralized lubrication systems.
Open the catalog to page 1Pump overview Flow rate Oil Fluid grease [l/min] Reservoir capacity Reservoir material [litres] Design features / Special technical features 24 V mit lubricant level switch with M12×1 plug connector 24 V level monitoring with M12×1 plug connector Motor with Harting connector Two 24 V lubricant level switches for minimum and advance warning Two 24 V lubricant level switches for minimum and advance warning Two 24 V lubricant level switches for minimum and advance warning Two 24 V lubricant level switches for min. and max. level Two 24 V lubricant level switches for minimum and advance warning...
Open the catalog to page 2Pump overview CAUTION The important information on product usage located on the back cover applies to all systems described in this brochure. Gear pump units MFE2 Reservoir material Plastic Metal Lubricant Fluid grease Page 4/5 Fill level monitoring optional Reservoir capacity 3 or 6 litres Flow rate 0.2 l/min Gear pump units MFE5 Reservoir material Plastic Lubricant Oil Page 10 Fill level monitoring optional Reservoir capacity 3, 6 or 15 litres Flow rate 0.5 l/min Gear pump units MFE5 Reservoir material Metal Lubricant Oil Page 9/11 Fill level monitoring optional Reservoir capacity 3, 6 or...
Open the catalog to page 3MFE2 gear pump unit for fluid grease with main line automatic pressure relief These units are designed for centralized lubrication systems used in conjunction with piston distributors (total-loss lubrication) and are equipped with the required relief and safety valves. The drive is provided by a three-phase motor. The pumps are located below the grease level, in contrast to oil units. Intermittent operation is required for the distributors’ sequence of operation: when the pump is running, the distributors are pressurized, when the pump is at rest, the main line is relieved of pressure and...
Open the catalog to page 4MFE2 gear pump unit for fluid grease with main line automatic pressure relief Technical data Voltage (please indicate range when ordering) Unit Flow rate . . . . . . . . . . . . . . . . . . . . . . . Continuous operation at p max. . . . . . Brief operation at p max. . . . . . . . . . . . Operation temperature . . . . . . . . . . . . Mounting position . . . . . . . . . . . . . . . . Lubricant . . . . . . . . . . . . . . . . . . . . . . . Motor Rated power . . . . . . . . . . . . . . . . . . . . . Speed 1) . . . . . . . . . . . . . . . . . . . . . . . . Type of enclosure to DIN 40050 . . . ....
Open the catalog to page 5MFE5 gear pump unit for oil Gear pump unit mounted separate from oil reservoir Order No. Gear pump unit for flange-mounting on oil reservoir Please provide voltage and frequency when ordering. A special sealed pump must be used for horizontal flange-mounting of the unit in a position below the oil level. For gear pump unit model MFE5 complete with metal or plastic reservoir (3, 6 and 15 liters) see the pages 9 – 11.
Open the catalog to page 6MFE5 gear pump unit for oil Explanation of hydraulic function Both (ME5, MFE5) types have the same hydraulic function. Oil is sucked in at S and flows under pressure through the duct in the direction P. The oil pressure closes valve V and opens valve E3, at the same time closing valve E1 against spring tension. If air is entrained (due to low oil level in the reservoir), valve V remains open and diverts the air or, respectively, the air-oil mixture into the return duct (see bubble (o) marking in direction R1). Valve C allows oil under overpressure to flow out into the return duct (see cross...
Open the catalog to page 7Multi-voltage motors for pump units (assembly M..) Many export oriented companies have to deal with voltages/frequencies that deviate from those in Germany. To make it easier for them to buy the most common pump units for centralized lubrication systems, we have developed 3 multirange motors that cover a wide range of three-phase voltages and frequencies. Pump units with or without oil reservoirs are included, provided the hydraulic power data listed in the brochures are not exceeded (limit values). These pump units are designated as: M2, MF2, MFE2, M5, MF5, MFE5, FLM12-3, FLMF12-3, M202...
Open the catalog to page 8MFE5 gear pump unit with 3 or 6 liter meatl reservoir Reservoir Reservoir capacity material [litres] Order No. without float switch die-cast aluminum sheet steel Flow rate [l/min] 4) When ordering, the order no. should be supplemented with the power key. Technical data Float switch (WS) for monitoring of minimum oil level 1 changeover 230 V AC / 230 V DC 1.0 A 60 VA / 40 W 5) IP 65 –10 to +60 °C Return G 1/2 with screw plug Type of contact . . . . . . . . . . . . . . . . . . . . Max. switching voltage . . . . . . . . . . . . . . Max. switching current . . . . . . . . . . . . . . Max....
Open the catalog to page 9MFE5 gear pump unit with 3 or 6 liter plastic reservoir Flow rate [l/min] Reservoir Reservoir capacity material [litres] Order No. without float switch 4) When ordering, the order no. should be supplemented with the power key. Technical data Float switch (WS) for monitoring the minimum level Type of contact . . . . . . . . . . . . . . . . . . . . Max. switching voltage . . . . . . . . . . . . . . Max. switching current . . . . . . . . . . . . . . Max. switching capacity . . . . . . . . . . . . . Type of enclosure . . . . . . . . . . . . . . . . . . Temperature range . . . . . . . . . . . ....
Open the catalog to page 10MFE5 gear pump unit with 15 liter sheet steel reservoir Flow rate [l/min] Reservoir Reservoir capacity material [litres] foot-mounted reservoir sheet steel reservoir 3) When ordering, the order no. should be supplemented with the power key. max. Technical data Float switch (WS) to monitor the critical level of oil with advance warning about 25 mm before the minimum oil level is reached. Type of contact . . . . . . . . . . . . . . . . . . . . Max. switching voltage . . . . . . . . . . . . . . Max. switching current . . . . . . . . . . . . . . Max. switching capacity . . . . . . . . . . . . ....
Open the catalog to page 11All SKF Lincoln Automatic Lubrication Systems catalogs and technical brochures
-
Pump unit PPS30
4 Pages
-
ECP Product brochure
8 Pages
-
Product series 143 brochure
24 Pages
-
Wire rope lubrication system
8 Pages
-
Single- and Multi-circuit Pumps
16 Pages
-
LubriLean brochure
4 Pages
-
1154 flyer
2 Pages
-
EDL1 product brochure
4 Pages
-
DSA product brochure
4 Pages
-
DSC3 product brochure
4 Pages
-
DSB product brochure
4 Pages
-
HCC product brochure
2 Pages
-
LMC 301 product brochure
8 Pages
-
SFZM product brochure
4 Pages
-
SP/SMB14 product brochure
8 Pages
-
SP/SMB13 product brochure
8 Pages
-
SMBM product brochure
18 Pages
-
Safeflow product brochure
4 Pages
-
SMT 1 product brochure
8 Pages
-
LP2 / LPC product brochure
8 Pages
-
PSG product brochure
36 Pages
-
VP product brochure
20 Pages
-
VPK product brochure
20 Pages
-
VPB product brochure
12 Pages
-
SPVS product brochure
8 Pages
-
SKF Maxilube Solution
8 Pages
-
SGA/SG product brochure
6 Pages
-
SLC product brochure
12 Pages
-
SL-6 product brochure
4 Pages
-
SL-32HV product brochure
2 Pages
-
310 series product brochure
4 Pages
-
BPH product brochure
4 Pages
-
Lubrigun product brochure
15 Pages
-
EOP2 product brochure
2 Pages
-
MPB product brochure
2 Pages
-
FK product brochure
12 Pages
-
VectoLub product brochure
30 Pages
-
P502 product brochure
2 Pages
-
LubriLean product brochure
16 Pages
-
P603S product brochure
8 Pages
-
P212 product brochure
2 Pages
-
P205/ P215 product brochure
2 Pages
-
MKx series product brochure
24 Pages
-
Product Series OLA, MV and 161
28 Pages
-
CLK product brochure
8 Pages
-
Pulse meter IPM
4 Pages
-
Gear wheel indicator SFZM
4 Pages
-
Oil conditioning unit OCU
4 Pages
-
LFC 5000
4 Pages
-
SSV-D
2 Pages
-
Improved Centro-Matic SL-11
12 Pages
-
SL-V XL
4 Pages
-
12-volt Reel 'n F
2 Pages
-
New 90-lb. Reservoir
12 Pages
-
HTL 429
4 Pages
-
Lincoln
8 Pages
-
AC FlowMaster
12 Pages
-
EOS
2 Pages
-
LFR Series
4 Pages
-
Hand Vacuum Pumps
6 Pages
-
Pumps PMV Pump Family
16 Pages