Flowline Monitor product brochure
8Pages

{{requestButtons}}

Catalog excerpts

Flowline Monitor product brochure - 1

SKF Flowline Monitor Flow rate control and monitoring for oil circulation lubrication systems

Open the catalog to page 1
Flowline Monitor product brochure - 2

Reliable flow rate control and monitoring Oil circulation systems are used for lubrication, cooling and particle removal in pulp and paper, mining and many other heavy industry applications. The SKF Flowline Monitor was developed to measure and control the oil flow rates in these lubrication systems. The SKF Flowline Monitor is simple to use and allows operators to see the flow rate status of each individual lubrication point. The three different FL types enable control and monitoring of oil flows from 0,1 to 100 l/min with operating oil viscosities from 32 to 1 000 mm2/s. Utilizing...

Open the catalog to page 2
Flowline Monitor product brochure - 3

Energy efficient and accurate operation User-friendly keypad Traffic light feature The SKF Flowline Monitor’s keypad is easy to operate. Flow rates and settings can be viewed on the digital display. All settings can be adjusted using the keypad. The LED indicators in the flow meters show a visual indication of oil flow volume. Any deviation from set point can be detected by the different LED indicator colours. Red indicates that the flow rate is below the low alarm-limit value and yellow indicates that the flow rate is above the high alarm-limit value. When the green LED indicators are on,...

Open the catalog to page 3
Flowline Monitor product brochure - 4

Modular system to meet customer’s monitoring requirements A standard SKF Flowline Monitor includes one common alarm, which is included in basic FL group electronics. In addition to the standard version, optional modular interfaces make it easy to choose the right monitoring options for your solution: • CAN module with CAN bus connections • Analogue module with 4-20 mA output for each lubrication point • RC module with combined relay and CAN bus connections (RCM) There is a reserved slot for this optional module in all SKF Flowline Monitor models: FL15, FL50 and FL100. Interface to process...

Open the catalog to page 4
Flowline Monitor product brochure - 5

CAN module The CAN bus interface is used for connecting the monitors to remote control and monitoring systems. Various fieldbus alternatives are available for connecting to customer’s DCS systems by using standard CAN/Fieldbus gateways: • Modbus RTU • Modbus TCP • Profibus • Ethernet/IP SKF Flowline Hub and Flowline Software can be used with CAN bus interface to build a stand-alone, PC-based control and monitoring system. Applications: • Systems where one or several lubrication points must be monitored individually or are located in a wide area • Paper machine dryer sections, etc. Analogue...

Open the catalog to page 5
Flowline Monitor product brochure - 6

Technical data Flow meter type FL15 Flow rate Group size Viscosity range Operating pressure (max.) Operating temperature Protection class Power supply Power consumption Alarm relay 32–1 000 mm2/s 10 bar (145 psi) 0 to + 65 °C (+32 to 150 °F) IP 65 20–36 V DC 24 V AC (-20 to + 5%) 5W Potential free contact; max. load 30 V DC / 1 A, 120 V AC / 1 A, resistive load Inlet connections Outlet connections Flow meter type Mounting options Supply piping assembly • Easy and flexible panel installation with optional legs, wall brackets or hood mounting frame • Many standard panel sizes for up to 60...

Open the catalog to page 6
Flowline Monitor product brochure - 7

Identification code Product series SKF Flowline Monitor Product type 15 = FL15 Number of flow meters 01 = FL50 or FL100 with 1 single flow meter 02 = FL15 or FL50 with 2 flow meters 04 = FL15 with 4 flow meters 06 = FL15 with 6 flow meters 08 = FL15 with 8 flow meters 10 = FL15 with 10 flow meters Connection thread R = BSPP Interface card (optional) CAN = CAN bus interface module RCM = Relay and CAN bus interface module Flow meters with BSPP connection thread Flow meters with NPT connection thread Order number Number of flow meters Interface card Order number Number of flow meters Interface...

Open the catalog to page 7
Flowline Monitor product brochure - 8

Important information on product usage SKF and Lincoln lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure (1 013 mbar) by more than 0,5 bar at their maximum permissible temperature. skf.com | skf.com/flowlinemonitor | skf-lube@skf.com ® SKF is a registered trademark of the SKF Group. © SKF Group 2022 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is...

Open the catalog to page 8

All SKF Lincoln Automatic Lubrication Systems catalogs and technical brochures

  1. 1154 flyer

    2 Pages

  2. LFC 5000

    4 Pages

  3. SSV-D

    2 Pages

  4. SL-V XL

    4 Pages

  5. HTL 429

    4 Pages

  6. Lincoln

    8 Pages

  7. AC FlowMaster

    12 Pages

  8. EOS

    2 Pages

  9. LFR Series

    4 Pages