Catalog excerpts
Thermo-FID TG Flameionisationdetector - tablehousing Technical data Weight Injectors Weight Membrane pump Dimension Injectors Dimension Membrane pump Measured value display < 4% above measurement range Measured value output 0(4)mA to 20mA; burden 600Ω not galvanically isolated Ambient temperature with injectors General application The Thermo-FID is applied in a variety of applications for all kind of industries, environmental protection and as well for research and development. The implementations reach from an LEL-control, over emission and immission control to analytical exhaust control for the chemical industry and in the field of engine-development. Furthermore there is process optimisation and the FID is also used in the field of analytical control of TLV- and TRC- values. Ambient temperature with membrane pump The Thermo-FID TG is a Totalhydrocarbon-analysor in a table housing. Burnerair and zerogas are standardised over catalyst. The sample gas conveyance takes place with injectors over the external instrument air. (Leakage control; Exhaust Emission control; Plant monitoring; Methanefree Measurements) Technical design < 50% rel. humidity, + 40°C Geographical altitude The electronic system of the FID allows several extra functions. The integrated CPU allows a menu-driven handling as well as a full automatic self-control and failure analysis of the system. On the alphanumeric display are shown several operation and service instructions in clear text which give an easy maintenance process. The process-controlled and dynamic amplifier analysis always within the optimum range. The amplified signals are digitised directly at the detector and get transmitted as digital data to the CPU for the analysis. Therefore there is no distortion of the little currents because of badly shielded or too long signa
Open the catalog to page 117. BImSchV / TA Air (936/806016) QAL 1 (DIN EN 14181 and DIN EN ISO 14956) MCerts (Sira MC 050062/00) Vacuum system Membrane pump Measurement range Detection limit Response time (T90) Samplegas (self-drawed) Supplementary heating system (PT100) < 0.5 s if measured value > 20 mg org.C/m³ < 5.0 s if measured value < 20 mg org.C/m³ ca. 25 l/h with 1013 hPa alternative ca. 2 l/h; ca. 5 l/h; ca. 60 l/h 3.0 Bar to 3.9 Bar / < 2 Nm³/h Quality to ISO8573-1 minimum 1.2.1 Ambient air over Membrane pump Hydrogen 0.7 Bar to 1.0 Bar / < 80 ml/min Quality 5.0 Over internal catalyst or optional Synthetic...
Open the catalog to page 2Back side FID TG with methane catalyst Front FID TG with methane catalyst and stand Order data Thermo-FID 'TG' Options 4x 0/4-20mA galv. separation/ 4 potentialfree alarmcontacts inclusive Status-/Alarmboard Internal Membrane pump Set membrane pump internal sample-gas pump External Membrane pumpe Set membrane pump external sample-gas pump Dilution Probe heated without enclosure Conversion kit Zero gas external to measure two measuring streams Status- and alarmboard Module Methanefree-Methane Dilution probe 1:10/ 1:20 External Zerogas Heated 2/3 Direction Control Valve 180°C max. For E S, TG...
Open the catalog to page 3www.sk-elektronik.de sales@sk-elektronik.de
Open the catalog to page 4All SK ELEKTRONIK GMBH catalogs and technical brochures
-
Thermo-FID MK and MK IP65
4 Pages
-
Thermo-FID PT84/LT
4 Pages
-
Thermo-FID PT63FH/LT
4 Pages
-
Thermo-FID FE and FE IP65
4 Pages
-
Thermo-FID ES
4 Pages