Thermo-FID TG

Thermo-FID TG

Thermo-FID TG

Product catalog summary
Technical Specifications:
The Thermo-FID TG is a flame ionization detector housed in a table unit. It weighs 9 kg for injectors and 10 kg for the membrane pump. The dimensions for injectors are 483 mm (W) x 135 mm (H) x 310 mm (D), and for the membrane pump, 445 mm (W) x 154 mm (H) x 320 mm (D). The device displays measured values in ppm, mg/m³, g/m³, Vol%, and %UEG with a linearity of less than 4% above the measurement range. It operates within ambient temperatures of -5°C to 40°C with injectors and +5°C to 40°C with the membrane pump, and supports air humidity levels of less than 90% at 20°C and less than 50% at 40°C. The geographical altitude range is 0 to 1500 m above NN, and it has a protection class of IP20.
General Application:
The Thermo-FID TG is used across various industries for environmental protection, research, and development. Applications include LEL-control, emission and immission control, analytical exhaust control in the chemical industry, engine development, process optimization, and analytical control of TLV and TRC values.
Technical Design:
The FID features an electronic system with an integrated CPU for menu-driven handling, automatic self-control, and failure analysis. It includes an alphanumeric display for operation and service instructions, and a process-controlled dynamic amplifier for optimal range analysis. Signals are digitized directly at the detector to prevent distortion.
Accreditation:
The device is accredited under 17. BImSchV / TA Air (936/806016), QAL 1 (DIN EN 14181 and DIN EN ISO 14956), and MCERTS (Sira MC 050062/00).
Measurement and Detection:
The measurement range for injectors is 0.5 mg org.C/m³ to 100000 mg org.C/m³, and for the membrane pump, 2 mg org.C/m³ to 100000 mg org.C/m³. The detection limit is less than 0.01 mg org.C/m³ for injectors and less than 0.05 mg org.C/m³ for the membrane pump. Response time (T90) is less than 0.5 s for values above 20 mg org.C/m³ and less than 5.0 s for values below 20 mg org.C/m³.
Order Data and Options:
Various options are available, including status and alarm boards, methane-free modules, internal and external membrane pumps, dilution probes, external zero gas conversion kits, and heated control valves. Additional accessories include in-line strippers and flame traps.
Contact Information:
SK Elektronik GmbH, Benzstr. 23-25, D-51381 Leverkusen, Tel. +49 2171 3955-0, Fax. +49 3955-49, www.sk-elektronik.de, [email protected]
See more

Catalog excerpts

Thermo-FID TG-1

Thermo-FID TG Flameionisationdetector - tablehousing Technical data Weight Injectors Weight Membrane pump Dimension Injectors Dimension Membrane pump Measured value display < 4% above measurement range Measured value output 0(4)mA to 20mA; burden 600Ω not galvanically isolated Ambient temperature with injectors General application The Thermo-FID is applied in a variety of applications for all kind of industries, environmental protection and as well for research and development. The implementations reach from an LEL-control, over emission and immission control to analytical exhaust control for the chemical industry and in the field of engine-development. Furthermore there is process optimisation and the FID is also used in the field of analytical control of TLV- and TRC- values. Ambient temperature with membrane pump The Thermo-FID TG is a Totalhydrocarbon-analysor in a table housing. Burnerair and zerogas are standardised over catalyst. The sample gas conveyance takes place with injectors over the external instrument air. (Leakage control; Exhaust Emission control; Plant monitoring; Methanefree Measurements) Technical design < 50% rel. humidity, + 40°C Geographical altitude The electronic system of the FID allows several extra functions. The integrated CPU allows a menu-driven handling as well as a full automatic self-control and failure analysis of the system. On the alphanumeric display are shown several operation and service instructions in clear text which give an easy maintenance process. The process-controlled and dynamic amplifier analysis always within the optimum range. The amplified signals are digitised directly at the detector and get transmitted as digital data to the CPU for the analysis. Therefore there is no distortion of the little currents because of badly shielded or too long signa

 Open the catalog to page 1
Thermo-FID TG-2

17. BImSchV / TA Air (936/806016) QAL 1 (DIN EN 14181 and DIN EN ISO 14956) MCerts (Sira MC 050062/00) Vacuum system Membrane pump Measurement range Detection limit Response time (T90) Samplegas (self-drawed) Supplementary heating system (PT100) < 0.5 s if measured value > 20 mg org.C/m³ < 5.0 s if measured value < 20 mg org.C/m³ ca. 25 l/h with 1013 hPa alternative ca. 2 l/h; ca. 5 l/h; ca. 60 l/h 3.0 Bar to 3.9 Bar / < 2 Nm³/h Quality to ISO8573-1 minimum 1.2.1 Ambient air over Membrane pump Hydrogen 0.7 Bar to 1.0 Bar / < 80 ml/min Quality 5.0 Over internal catalyst or optional Synthetic air...

 Open the catalog to page 2
Thermo-FID TG-3

Back side FID TG with methane catalyst Front FID TG with methane catalyst and stand Order data Thermo-FID 'TG' Options 4x 0/4-20mA galv. separation/ 4 potentialfree alarmcontacts inclusive Status-/Alarmboard Internal Membrane pump Set membrane pump internal sample-gas pump External Membrane pumpe Set membrane pump external sample-gas pump Dilution Probe heated without enclosure Conversion kit Zero gas external to measure two measuring streams Status- and alarmboard Module Methanefree-Methane Dilution probe 1:10/ 1:20 External Zerogas Heated 2/3 Direction Control Valve 180°C max. For E S, TG and...