Catalog excerpts
Thermo-FID PT84/LT Flameionisationdetecor – Portable Technical data Models Weight PT/LT Weight PT with bottleholder (without bottles) Dimension PT/LT Dimension PT with bottleholder Measured value display The Thermo-FID PT84 is a completely mounted analyser with a portable 2/3 19" rack. Optional there ca be adapted a bottleholder or a pressure-regulator for hydrogen and spangas. Burnerair and zerogas are standardised over catalyst. The sample gas conveyance takes place over the internal membrane pump.(Leakage control; Exhaust Emission control; Plant monitoring; Methanefree measurements) < 4% above measurement range Measured value output 0(4)mA to 20mA; burden 600Ω not galvanically isolated General application The Thermo-FID is applied in a variety of applications for all kind of industries, environmental protection and as well for research and development. The implementations reach from an LEL-control, over emission and immission control to analytical exhaust control for the chemical industry and in the field of engine-development. Furthermore there is process optimisation and the FID is also used in the field of analytical control of TLV- and TRC- values. Technical design Ambient temperature PT63/LT Geographical altitude The electronic system of the FID allows several extra functions. The integrated CPU allows a menu-driven handling as well as a full automatic self-control and failure analysis of the system. On the alphanumeric display are shown several operation and service instructions in clear text which give an easy maintenance process. The process-controlled and dynamic amplifier analysis always within the optimum range. The amplified signals are digitised directly at the detector and get transmitted as digital data to the CPU for the analysis. Therefore there is no distortion of the little currents because of badly shielded or too long sig
Open the catalog to page 1Accredita 17. BImSchV / TA Air (936/806016) QAL 1 (DIN EN 14181 and DIN EN ISO 14956) MCerts (Sira MC 050062/00) Vaccum System Membrane pump 2 mg org.C/m³ to 100.000 mg org.C/m³ Measurement range Detection limit < 0.05 mg org.C/m³ < 0.5 s if measured value > 20 mg org.C/m³ < 5.0 s if measured value < 20 mg org.C/m³ Response time (T90) Samplegas (self-drawed) Supplementary heating system (PT100) Ambient air above Membrane pump Hydrogen 0.7 Bar to 1.0 Bar / < 80 ml/min Quality 5.0 Over internal catalyst 2.0 Bar bis 2.5 Bar / < 130 Nl/h Konzentration 60 % to 80 % of the measurement range In...
Open the catalog to page 2Back PT84 with bottleholder Order data Thermo-FID ‚PT84’ Thermo-FID ‚PT84/LT’ Thermo-FID Portable ‚PT84’ with bottleholder Thermo-FID Portable ‚PT84’/LT (without bottleholer) Options Gas bottle regulator/ pressure regulator 84 TE for Hydrogen and span gas Modul Methanefree-Methane Inclusive Status-/Alarmboard Supplementary regulators Internal Membrane pump External Membrane pump Dilution probe 1:10/ 1:20 Conversion kit Zero gas external Conversion kit Zero gas external and synthetic Air as Burnerair In Line Flame Trap FS 30 Eex dIIC Flame Trap ATEX 94/9/EG Dilution probe heated without...
Open the catalog to page 3www.sk-elektronik.de sales@sk-elektronik.de
Open the catalog to page 4All SK ELEKTRONIK GMBH catalogs and technical brochures
-
Thermo-FID MK and MK IP65
4 Pages
-
Thermo-FID PT63FH/LT
4 Pages
-
Thermo-FID FE and FE IP65
4 Pages
-
Thermo-FID TG
4 Pages
-
Thermo-FID ES
4 Pages