Catalog excerpts
Thermo-FID PT63FH/LT Flameionisationdetector – Portable Technical data Models Weight PT/LT Weight PT with bottleholder (without bottles) Dimension PT/LT Dimesion PT with bottleholder Measured value display The Thermo-FID PT63 is a completely mounted analyser with a portable 2/3 19“ rack. Optional there can be adapted a bottleholder or a pressure-regulator for hydrogen and spangas. Burnerair and zerogas are standardised over catalyst. The sample gas conveyance takes place over the internal membrane pump. (Leakage control; Exhaust Emission control; Plant monitoring) < 4% above measurement range Measured value output 0(4)mA to 20mA; burden 600Ω not galvanically isolated General application The Thermo-FID is applied in a variety of applications for all kind of industries, environmental protection and as well for research and development. The implementations reach from an LEL-control, over emission and immission control to analytical exhaust control for the chemical industry and in the field of engine-development. Furthermore there is process optimisation and the FID is also used in the field of analytical control of TLV- and TRC- values. Technical design Ambient temperature PT63/LT Geographical altitude The electronic system of the FID allows several extra functions. The integrated CPU allows a menu-driven handling as well as a full automatic self-control and failure analysis of the system. On the alphanumeric display are shown several operation and service instructions in clear text which give an easy maintenance process. The process-controlled and dynamic amplifier analysis always within the optimum range. The amplified signals are digitised directly at the detector and get transmitted as digital data to the CPU for the analysis. Therefore there is no distortion of the little currents because of badly shielded or too long s
Open the catalog to page 1Accreditation 17. BImSchV / TA Air (936/806016) QAL 1 (DIN EN 14181 and DIN EN ISO 14956) MCerts (Sira MC 050062/00) Vacuum System Membrane pump 2 mg org.C/m³ to 100000 mg org.C/m³ Measurement range Detection limit < 0.05 mg org.C/m³ < 0.5 s if measured value > 20 mg org.C/m³ < 5.0 s if measured value < 20 mg org.C/m³ Response time (T90) Samplegas (self-drawed) Supplementary heating system (PT100) Ambient air above Membrane pump Hydrogen 0.7 Bar to 1.0 Bar / < 80 ml/min Quality 5.0 Over internal catalyst 2.0 Bar to 2.5 Bar / < 130 Nl/h concentration 60 % to 80 % of the measurement range In...
Open the catalog to page 2Front PT63/LT with stand Front PT63 with bottleholder Order data Thermo-FID 'PT63' Thermo-FID 'PT63/LT' Thermo-FID Portable 'PT' with bottleholder Thermo-FID Portable 'PT'/LT (without bottleholder) Options Gas bottle regulator/ pressure regulator 63 TE for Hydrogen and span gas Internal Membrane pump External Membrane pump Dilution probe 1:10/ 1:20 External Zerogas Synthetic Air for Burnerair Flame Trap ATEX 94/9/EG Dilution probe heated without enclosure Conversion kit Zero gas external Conversion kit Zero gas external and synthetic Air as Burnerair In Line Flame Trap FS 30 Eex dIIC
Open the catalog to page 3www.sk-elektronik.de sales@sk-elektronik.de
Open the catalog to page 4All SK ELEKTRONIK GMBH catalogs and technical brochures
-
Thermo-FID MK and MK IP65
4 Pages
-
Thermo-FID PT84/LT
4 Pages
-
Thermo-FID FE and FE IP65
4 Pages
-
Thermo-FID TG
4 Pages
-
Thermo-FID ES
4 Pages