Thermo-FID FE and FE IP65
4Pages

{{requestButtons}}

Catalog excerpts

Thermo-FID FE and FE IP65 - 1

Thermo-FID FE and FE IP65 Flameionisationdetector – Fieldhousing Technical data Models Measured value display Completely mounted analyser in a fieldhousing for the rough applications in the field. Especially for wall fastening or a panel construction within analytical chambers. Over a status signal or by the remotecontrol-function it is possible to control and see the analyser function in real-time. The housing is in protection class IP54, but there is as well a version for the Exarea of zone 1 including the protection class „over pressure casing" EEx p following ATEX 94/9/EG and the version IP65. (Leakage control; Exhaust Emission control; Plant monitoring) General application < 4% above measurement range Measured value output 0(4)mA to 20mA; burden 600Ω not galvanically isolated Ambient temperature The Thermo-FID is applied in a variety of applications for all kind of industries, environmental protection and as well for research and development. The implementations reach from a LEL-control, over emission and immission control to analytical exhaust control for the chemical industry and in the field of engine-development. Furthermore there is process optimisation and the FID is also used in the field of analytical control of TLV- and TRC- values. Technical design The electronic system of the FID allows several extra functions. The integrated CPU allows a menu-driven handling as well as a full automatic self-control and failure analysis of the system. On the alphanumeric display are shown several operation and service instructions in clear text which give an easy maintenance process. The process-controlled and dynamic amplifier analysis always within the optimum range. The amplified signals are digitised directly at the detector and get transmitted as digital data to the CPU for the analysis. Therefore there is no distortion of the little currents because of badly shielded or too long signal ways. Geographical altitude

Open the catalog to page 1
Thermo-FID FE and FE IP65 - 2

Vacuum system Measurement range Detection limit Response time (T90) 17. BImSchV / TA Air (936/806016) QAL 1 (DIN EN 14181 and DIN EN ISO 14956) MCerts (Sira MC 050062/00) Injectors 0.5 mg org.C/m³ to 100000 mg org.C/m³ < 0.01 mg org.C/m³ < 0.5 s if measured value > 20 mg org.C/m³ < 5.0 s if measured value < 20 mg org.C/m³ Samplegas (self-drawed) Supplementary heating system (PT100) 3.0 Bar to 3.9 Bar /< 2 Nm³/h Quality to ISO8573-1 minimum 1.2.1 Hydrogen 0.7 Bar to 1,0 Bar / < 80 ml/min Quality 5.0 Over internal catalyst or optional Synthetic air 1.0 Bar to 1.5 Bar 2.0 Bar to 2.5 Bar / <...

Open the catalog to page 2
Thermo-FID FE and FE IP65 - 3

Order data Thermo-FID ‚FE’ 4 x 0/4-20mA galv. seperation/ 4 potentialfree alarmcontacts inklusive Status- / Alarmkarte Dilution probe heated without enclosure for FE Conversion kit zerogas external Conversion kit zerogas external and synthetic air as burnerair to measure two measuring streams Thermo-FID ‚FE IP65’ Thermo-FID ‚IP65’ with vortexcooler Options Status- and alarmboard Module Methanefree-Methane Dilution probe 1:10/ 1:20 External Zerogas Synthetic Air for Burnerair Heated 2/3 Direction Control Valve 180°C max. For E S, TG and FE Inlinestripper

Open the catalog to page 3
Thermo-FID FE and FE IP65 - 4

Steam relaxation unit www.sk-elektronik.de sales@sk-elektronik.de

Open the catalog to page 4