SISTO_Catalogue for Industry and Building Services_EN-1

Industry, Building Services Diaphragm Valves i Swing Check Valves i Actuators

 Open the catalog to page 1
SISTO_Catalogue for Industry and Building Services_EN-2

All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. © SISTO Armaturen S.A., Echternach, Luxemburg 2026-03-24

 Open the catalog to page 2
SISTO_Catalogue for Industry and Building Services_EN-4

1 Further applications on request 2 The temperatures indicated are for orientation only; they are not valid for all operating conditions.

 Open the catalog to page 4
SISTO_Catalogue for Industry and Building Services_EN-6

3SID Application Ranges of Materials Used Body coating ECTFE (Halar) ECTFE (Halar)

 Open the catalog to page 6
SISTO_Catalogue for Industry and Building Services_EN-7

3SID Application Ranges of Materials Used GP240GH (1.0619) (only applies to DN 15 with PFA liner) Body coating ECTFE (Halar) Body lining Body coating ECTFE (Halar) Body lining

 Open the catalog to page 7
SISTO_Catalogue for Industry and Building Services_EN-8

3SID Overview of Type Series Diaphragm valves SISTO-LAP Electric actuators ■ Pneumatic piston actuators for industrial use ■ Electric linear actuators ■ Electric multi-turn actuators

 Open the catalog to page 8
SISTO_Catalogue for Industry and Building Services_EN-10

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless SISTO-KB Product benefits ■ Reliable sealing ensured by one single sealing element (the diaphragm) which provides hermetic sealing to atmosphere and absolutely tight shut-off. The specially enclosed diaphragm ensures long service life and high operating reliability. ■ Low flow resistance achieved by streamlined design in a straight-way pattern with full bore ■ High resistance to corrosion and abrasion with high-quality body materials and linings...

 Open the catalog to page 10
SISTO_Catalogue for Industry and Building Services_EN-11

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless ■ Other fluids on request.

 Open the catalog to page 11
SISTO_Catalogue for Industry and Building Services_EN-12

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Operating properties Design details Design ■ Soft-seated shut-off valve in straight-way pattern ■ Shut-off and sealing to atmosphere by diaphragm ■ Position indicator with integrated stem protection ■ Marked in accordance with DIN EN 19 (ISO 5209) ■ Actuator (electric or pneumatic) ■ Body lined with HR (butyl), temperature limit: +120 °C ■ Body lined with NRH (hard rubber), temperature limit: +100 °C ■ Body coated with ECTFE (Halar) inside and outside, temperature limit: +90 °C ■ Body coated with PA (Rilsan) inside and...

 Open the catalog to page 12
SISTO_Catalogue for Industry and Building Services_EN-13

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless - Actuator type LAP-SF - Actuator type LAP-OF - Actuator type LAP-AZ Electric actuator - Multi-turn actuator - Linear actuator For information as per chemicals Regulation (EC) No. 1907/2006 (REACH), see https://sisto-aseptic.com/infopage/. The valves satisfy the safety requirements of Annex I of the European Pressure Equipment Directive 2014/68/EU (PED) for fluids in Groups 1 and 2. Valves without electrical components do not have a potential internal source of ignition and can be used in potentially explosive atmospheres,...

 Open the catalog to page 13
SISTO_Catalogue for Industry and Building Services_EN-14

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Please specify the following information in all enquiries or purchase orders: 10. Number of type series booklet 2. Control pressure Prtr Flow coefficients for unlined valves

 Open the catalog to page 14
SISTO_Catalogue for Industry and Building Services_EN-15

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Parts list 6 Recommended spare parts

 Open the catalog to page 15
SISTO_Catalogue for Industry and Building Services_EN-16

Diaphragm ValvesDiaphragm Valves - No Dead Volume, Soft-seated, GlandlessMaterials of the directly mounted DLAP.230 piston actuator Parts list 7 Recommended spare parts

 Open the catalog to page 16
SISTO_Catalogue for Industry and Building Services_EN-17

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Fig. 7: SISTO-LAP-SF piston actuator Parts list 8 Recommended spare parts (= complete set of sealing elements) 9 We recommend having these parts replaced in our factory.

 Open the catalog to page 17
SISTO_Catalogue for Industry and Building Services_EN-18

Diaphragm Valves Diaphragm Valves No Dead Volume, Soft-seated, Glandless Variants and accessoriesVariants and accessories of SISTO-KB manually operated valves Variants of SISTO-KB with actuator 18

 Open the catalog to page 18
SISTO_Catalogue for Industry and Building Services_EN-19

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless

 Open the catalog to page 19
SISTO_Catalogue for Industry and Building Services_EN-20

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless

 Open the catalog to page 20
SISTO_Catalogue for Industry and Building Services_EN-21

Diaphragm ValvesDiaphragm Valves - No Dead Volume, Soft-seated, Glandless Configuration with mechanical limit switches LAP-SF type with double piston Configuration with positioner G G '/a in. for piston diameters 80/125/160 G % in. for piston diameters 200/250/300 M 20 for piston diameters 160 to 300 M 24 for piston diameters D300/F14 optional

 Open the catalog to page 21
SISTO_Catalogue for Industry and Building Services_EN-22

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Prepared for SISTO-LAP piston actuator or electric actuator Mating dimensions as per standard Face-to-face lengths: Flanges: Flange facing: 10 Add 5 mm to centre-to-top height for rubber-lined valves.

 Open the catalog to page 22
SISTO_Catalogue for Industry and Building Services_EN-23

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless

 Open the catalog to page 23
SISTO_Catalogue for Industry and Building Services_EN-24

Diaphragm ValvesDiaphragm Valves - No Dead Volume, Soft-seated, GlandlessDimensions and weights of SISTO-LAP piston actuator Fig. 10: SISTO-LAP Dimensions and weights for actuator function: type LAP-SF (air-to-open/spring-to-dose)

 Open the catalog to page 24
SISTO_Catalogue for Industry and Building Services_EN-25

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless

 Open the catalog to page 25
SISTO_Catalogue for Industry and Building Services_EN-26

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Selection table for maximum permissible operating pressure in bar for SISTO-KB Minimum required control pressure: 5.5 bar Maximum permissible control pressure 7 bar Operating pressure for pressure applied on one side in accordance with EN12266-1. Information on operating pressures applied on both sides is available on request. Operating pressure [bar] for actuator function: type SF (air-to-open/spring-to-close)

 Open the catalog to page 26
SISTO_Catalogue for Industry and Building Services_EN-27

Diaphragm Valves Diaphragm Valves - No Dead Volume, Soft-seated, Glandless Other selection options on request.

 Open the catalog to page 27
SISTO_Catalogue for Industry and Building Services_EN-28

Diaphragm ValvesDiaphragm Valves - No Dead Volume, Soft-seated, GlandlessActuator size of SISTO-LAP piston actuatorSelection table for maximum permissible operating pressure in bar for SISTO-KB valve with elastomer diaphragm Minimum required control pressure: 5.5 bar Maximum permissible pressure 10 bar Other selection options on request

 Open the catalog to page 28
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.