General Data
SIPOS actuators are designed for automatic and safe operation of industrial valves, compliant with EN 15714-2. They can be mounted in any position, with a recommended regular mounting for ease of local operation. The actuators support modulating duty (class C) and intermittent duty (S4/S5) with a noise level below 70 dB(A). They feature a corrosion-resistant aluminum alloy housing with a standard 2K-EP-SS paint finish, offering protection in corrosivity categories C3 to C5.
Mechanical Data
The actuators provide adjustable cut-off forces ranging from 3.8 kN to 152 kN, with manual force options and various flange sizes. Stroke lengths vary from 50 mm to 400 mm, depending on the model. Positioning speeds are selectable in seven stages, with default settings provided for different operations.
Electrical Data
The actuators operate on single or three-phase AC voltage, with permissible voltage tolerances. They feature a frequency converter for motor speed adjustment and include motor protection via a thermistor. The PROFITRON model includes an electrical brake for precise control.
Dimensional Drawings
Detailed dimensional drawings are provided for various models, indicating mounting distances, connection types, and component placements.
Motor Protection
The PROFITRON allows for programmable motor protection, while the ECOTRON requires an optional feature (M18) for motor space heating. The motor winding temperature is monitored by a microcontroller, and heating is controlled via a DC voltage when the motor is off.
Voltage and Current Specifications
The actuators can handle voltage fluctuations between -30% and +20%. Lower voltage increases current, while higher voltage decreases it. The starting current should not exceed the nominal current, and specific force-dependent cut-off modes are detailed.
Control and Feedback Signals
The document outlines the binary and analog input/output configurations for both ECOTRON and PROFITRON models. PROFITRON supports more extensive configurations, including PROFIBUS and MODBUS communication channels.
Signal Assignment
Binary outputs for both models are detailed, with specific settings for different operational modes. The PROFITRON allows for optional free assignment of outputs, while the ECOTRON has predefined settings.
Connections
Detailed terminal and plug assignments are provided for direct and round plug connections. The document specifies the wiring requirements for control and feedback signals, including the need for shielded wires.
Position Recording
Position detection is achieved through a precision metal film potentiometer or a magnetic position sensor. The document describes the adaptive functionality of the positioner, which adjusts control thresholds based on system feedback.
Power and Consumption Values
Specifications for binary and analog inputs/outputs are provided, including current and resistance values. The document also details the external 24V power supply requirements and consumption for various configurations.
Wiring Diagrams
Several wiring diagrams are included, illustrating the connections for both ECOTRON and PROFITRON models with and without relay boards. These diagrams provide guidance on internal and external power supply configurations.
Power Supply
The actuators can be powered by either internal or external 24V DC supplies. Internal supply powers binary inputs and outputs directly from the electronics unit, while external supply involves galvanically separated 24V DC sources. The maximum wire cross-section for power supply is 6 mm², and for control/feedback signals, it is 2.5 mm².
Options and Interfaces
The document mentions various optional features such as gold-plated contacts, Bluetooth interface (option "C50"), and PC cable (option "S38"). It also covers communication capabilities via COM-SIPOS and fieldbus for parameter changes and data downloads.
Additional Notes
The document includes specific instructions for maintaining signal continuity during mains failure and highlights the importance of galvanically separated areas for different power sources.
See more

Catalog excerpts

Tecnical Data SIPOS 5 linear actuators 2SB5-1

Technical Data Electric Linear Actuators 2SB5 Contents Page General data • Mounting position, duty classification, noise level, paint finish and 2-3 corrosion protection, lubrication, degree of protection, ambient Mechanical data • Thrust, cut-off force, manual force, flange size, stroke, travel, 4-5 positioning speed Electrical data • Power supply 11 • Control and feedback signals 12-14 • Wiring diagrams - Direct connection 15-18 Subject to changes without notice!

 Open the catalog to page 1
Tecnical Data SIPOS 5 linear actuators 2SB5-2

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data General data SIPOS actuators are suitable for automatic and safe operation of industrial valves in accordance with EN 15714-2. Mounting Position The actuator can be mounted in any position. To make local operation easier, e.g. reading information on the display, a regular mounting is recommended, i.e. the mounting flange of the valve should be positioned below the actuator. The electronics unit of the actuator can be mounted separately (e.g. wall bracket) using our separate mounting kit (e.g. Order add-on S41). Duty classifications Modulating...

 Open the catalog to page 2
Tecnical Data SIPOS 5 linear actuators 2SB5-3

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Lubrication The gears are filled with durable gear oil. They therefore require little maintenance. The maintenance intervals after commissioning must be observed (refer to recommendations in operating manual). During the lifetime the linear stage is maintenance free. Degree of Protection The actuators meet the requirements of IP67 protection as standard (DIN EN 60529). They are fully screen-protected (electrical voltage and moving parts) and protected against the ingress of foreign bodies (dust), and against harmful quantities of water...

 Open the catalog to page 3
Tecnical Data SIPOS 5 linear actuators 2SB5-4

Electric Linear Actuators 2SB5 (travel force under closed-loop control) Force for manual mode Crank length / » Switchover only when drive is at standstill! « Switchover takes place by pressing in the hand crank/hand wheel, motor stops operating automati- Electrical operation restarts automatically after releasing hand crank/hand wheel. Direction of rotation: Turning hand crank/ hand wheel clockwise results in an extension of the driving rod, that means the valve closes. Self-locking: The hand wheel acts directly on the motor shaft when turned by hand; the self-locking function is thus retained...

 Open the catalog to page 4
Tecnical Data SIPOS 5 linear actuators 2SB5-5

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data 1 2 3 4 5 6 7 - 8 9 10 11 12 2SB55 - 13 14 15 16 - Positioning speed Positioningspeed range Positioning speed [ /min] default setting for the cut-off force [kN] 25 - 100 1) 25 - 200 30 - 84 30 - 240 mm 3.8-7.7 70 7.7-15.4 1) 12.5-25 84 22.5-45 35 - 280 40 - 320 45-90 98 112 76-152 7-stage selectable positioning speed; step factor 1.4 Stage 4 is default setting Range Positioning speed setting Positioning speed set to stage … [mm/min] [mm/min] 25 - 100 1) 25 - 200 30 - 84 1) 30 - 240 35 - 280 40 - 320 1 2 3 4 5 25 35 50 70 100 30 42 60...

 Open the catalog to page 5
Tecnical Data SIPOS 5 linear actuators 2SB5-11

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Electrical data – Power supply of modulating duty Connection voltage UN 1-phase, 110 – 115 V AC (40 – 70 Hz) 1) permissible voltage tolerance: -10% / +15% (-30% / +20% ) vmax. Type [mm/min] 2SB551. 2SB552. 2SB553. -.CB -.CB -.CB 100 84 Fmax. [kN] Current (110 V) 2) 3) Nominal current IN 4) ≈ Imax. 5) [ A] [ A] 7.7 15.4 25 1.9 2.4 4.2 2.6 3.8 8.3 Power PN 4) [kW] 0.1 0.2 0.3 Motor power [kW] 0.75 Fuse slow blowing [ A] 10 small electronicsunit Connection voltage UN 1-phase, 220 – 230 V AC (40 – 70 Hz) 1) permissible voltage tolerance:...

 Open the catalog to page 11
Tecnical Data SIPOS 5 linear actuators 2SB5-12

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Electrical data – Control and feedback signals 1 2 3 4 5 6 7 - 8 9 10 11 12 - 2SB5 13 14 15 16 ECOTRON - 5/3 binary out-/inputs, analog actual position value PROFITRON - 8/4 binary out-/inputs, analog actual position value 3 4 electronics unit without hardware extension relay board - 5 outputs PROFIBUS DP 1 channel - with V1 and V2 services (V2 services only with PROFITRON) PROFIBUS DP 2 channel - with V1 and V2 services (only PROFITRON) MODBUS RTU 1 channel MODBUS RTU 2 channel (only PROFITRON) A B C D E F standard software-function...

 Open the catalog to page 12
Tecnical Data SIPOS 5 linear actuators 2SB5-13

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Connections - for direct connection (terminal assignment): ECOTRON PROFITRON Inputs X3.1 X3.2 X3.1 X3.2 X3.2 4, 5 and 6; 19 8, 9, 10, 11 and 12; 23, 24 --- 4, 5, 6 and 7; 19 and 20 8, 9, 10, 11, 12 and 13; 23, 24, 25 and 26 14, 15, 16 and 17 Outputs X3.1 1 and 2 1 and 2 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 13, 14, 15, 16, 17, 18, 19 and 20 3; 18, 21 and 22 P24 and M 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 13, 14, 15, 16, 17, 18, 19 and 20 3; 18, 21 and 22 P24 and M Inputs and outputs Binary Inputs Outputs Analog Terminals Relay outputs...

 Open the catalog to page 13
Tecnical Data SIPOS 5 linear actuators 2SB5-14

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Power and consumption values Binary inputs and outputs binary inputs binary outputs - Control inputs OPEN, CLOSED, STOP and Emergency (Emergency only on PROFITRON) - 8 binary electronic outputs for signals on PROFITRON, 5 outputs on ECOTRON All binary inputs and outputs are galvanically separated and potential-free. In addition, binary outputs are resistant to both short-circuits and overloads. Input Level Resistance 0 - 2,5 18 - 30 (typically 24) 4-7 max. 100 [Ω] Current (per input or output) Output 0-4 18 - 30 (typically 24) [mA] L...

 Open the catalog to page 14
Tecnical Data SIPOS 5 linear actuators 2SB5-15

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Wiring diagram ECOTRON-Direct connection Y070.058 Connection control and feedback signals Inputs Outputs analog binary binary max. 120mA Output 1) 1) Customer connection X3.1 1 2 3 4 5 6 7 8 9 10 11 12 13 X3.2 P24 int. / P24 G24 int. / G24 G24 int. P24 int. G24 int. / G24 G24 int. Output 5 Output 4 Output 3 Output 2 Output 1 Stop Open Close P24 int. Actuator internal + 0/4...20mA 0…600 - AO1 3) 14 15 16 17 18 19 20 21 22 23 24 25 26 Customer connection X1 P24 M N L1 X1 + 24V DC 2) N L PE P24 M L3 L2 L1 G24 ext. P24 ext. L1 N G24 ext....

 Open the catalog to page 15
Tecnical Data SIPOS 5 linear actuators 2SB5-16

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Wiring diagram ECOTRON-Direct connection with relay board Y070.062 Connection control and feedback signals Inputs Outputs analog binary binary max. 120mA Output 1) 1) X3.1 1 3 4 5 6 7 8 9 10 11 12 13 X3.2 P24 int. / P24 G24 int. / G24 G24 int. P24 int. 14 15 16 17 18 19 20 21 22 23 24 25 26 Relay board Output 1 P24 M X1 N X1 N L PE P24 M L2 L1 G24 ext. P24 ext. L1 + 24V DC 2) X2 L1 N G24 ext. P24 ext. Actuator internal Connection power supply Customer connection G24 int. / G24 G24 int. Output 5 Output 4 Output 3 Output 2 Output 1 Stop...

 Open the catalog to page 16