Tecnical Data SIPOS 5 linear actuators 2SB5
28Pages

{{requestButtons}}

Catalog excerpts

Tecnical Data SIPOS 5 linear actuators 2SB5 - 1

Technical Data Electric Linear Actuators 2SB5 Contents Page General data • Mounting position, duty classification, noise level, paint finish and 2-3 corrosion protection, lubrication, degree of protection, ambient Mechanical data • Thrust, cut-off force, manual force, flange size, stroke, travel, 4-5 positioning speed Electrical data • Power supply 11 • Control and feedback signals 12-14 • Wiring diagrams - Direct connection 15-18 Subject to changes without notice!

Open the catalog to page 1
Tecnical Data SIPOS 5 linear actuators 2SB5 - 2

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data General data SIPOS actuators are suitable for automatic and safe operation of industrial valves in accordance with EN 15714-2. Mounting Position The actuator can be mounted in any position. To make local operation easier, e.g. reading information on the display, a regular mounting is recommended, i.e. the mounting flange of the valve should be positioned below the actuator. The electronics unit of the actuator can be mounted separately (e.g. wall bracket) using our separate mounting kit (e.g. Order add-on S41). Duty classifications...

Open the catalog to page 2
Tecnical Data SIPOS 5 linear actuators 2SB5 - 3

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Lubrication The gears are filled with durable gear oil. They therefore require little maintenance. The maintenance intervals after commissioning must be observed (refer to recommendations in operating manual). During the lifetime the linear stage is maintenance free. Degree of Protection The actuators meet the requirements of IP67 protection as standard (DIN EN 60529). They are fully screen-protected (electrical voltage and moving parts) and protected against the ingress of foreign bodies (dust), and against harmful quantities of...

Open the catalog to page 3
Tecnical Data SIPOS 5 linear actuators 2SB5 - 4

Electric Linear Actuators 2SB5 (travel force under closed-loop control) Force for manual mode Crank length / » Switchover only when drive is at standstill! « Switchover takes place by pressing in the hand crank/hand wheel, motor stops operating automati- Electrical operation restarts automatically after releasing hand crank/hand wheel. Direction of rotation: Turning hand crank/ hand wheel clockwise results in an extension of the driving rod, that means the valve closes. Self-locking: The hand wheel acts directly on the motor shaft when turned by hand; the self-locking function is thus...

Open the catalog to page 4
Tecnical Data SIPOS 5 linear actuators 2SB5 - 5

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data 1 2 3 4 5 6 7 - 8 9 10 11 12 2SB55 - 13 14 15 16 - Positioning speed Positioningspeed range Positioning speed [ /min] default setting for the cut-off force [kN] 25 - 100 1) 25 - 200 30 - 84 30 - 240 mm 3.8-7.7 70 7.7-15.4 1) 12.5-25 84 22.5-45 35 - 280 40 - 320 45-90 98 112 76-152 7-stage selectable positioning speed; step factor 1.4 Stage 4 is default setting Range Positioning speed setting Positioning speed set to stage … [mm/min] [mm/min] 25 - 100 1) 25 - 200 30 - 84 1) 30 - 240 35 - 280 40 - 320 1 2 3 4 5 25 35 50 70 100 30 42...

Open the catalog to page 5
Tecnical Data SIPOS 5 linear actuators 2SB5 - 11

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Electrical data – Power supply of modulating duty Connection voltage UN 1-phase, 110 – 115 V AC (40 – 70 Hz) 1) permissible voltage tolerance: -10% / +15% (-30% / +20% ) vmax. Type [mm/min] 2SB551. 2SB552. 2SB553. -.CB -.CB -.CB 100 84 Fmax. [kN] Current (110 V) 2) 3) Nominal current IN 4) ≈ Imax. 5) [ A] [ A] 7.7 15.4 25 1.9 2.4 4.2 2.6 3.8 8.3 Power PN 4) [kW] 0.1 0.2 0.3 Motor power [kW] 0.75 Fuse slow blowing [ A] 10 small electronicsunit Connection voltage UN 1-phase, 220 – 230 V AC (40 – 70 Hz) 1) permissible voltage...

Open the catalog to page 11
Tecnical Data SIPOS 5 linear actuators 2SB5 - 12

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Electrical data – Control and feedback signals 1 2 3 4 5 6 7 - 8 9 10 11 12 - 2SB5 13 14 15 16 ECOTRON - 5/3 binary out-/inputs, analog actual position value PROFITRON - 8/4 binary out-/inputs, analog actual position value 3 4 electronics unit without hardware extension relay board - 5 outputs PROFIBUS DP 1 channel - with V1 and V2 services (V2 services only with PROFITRON) PROFIBUS DP 2 channel - with V1 and V2 services (only PROFITRON) MODBUS RTU 1 channel MODBUS RTU 2 channel (only PROFITRON) A B C D E F standard...

Open the catalog to page 12
Tecnical Data SIPOS 5 linear actuators 2SB5 - 13

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Connections - for direct connection (terminal assignment): ECOTRON PROFITRON Inputs X3.1 X3.2 X3.1 X3.2 X3.2 4, 5 and 6; 19 8, 9, 10, 11 and 12; 23, 24 --- 4, 5, 6 and 7; 19 and 20 8, 9, 10, 11, 12 and 13; 23, 24, 25 and 26 14, 15, 16 and 17 Outputs X3.1 1 and 2 1 and 2 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 13, 14, 15, 16, 17, 18, 19 and 20 3; 18, 21 and 22 P24 and M 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 13, 14, 15, 16, 17, 18, 19 and 20 3; 18, 21 and 22 P24 and M Inputs and outputs Binary Inputs Outputs Analog Terminals Relay...

Open the catalog to page 13
Tecnical Data SIPOS 5 linear actuators 2SB5 - 14

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Power and consumption values Binary inputs and outputs binary inputs binary outputs - Control inputs OPEN, CLOSED, STOP and Emergency (Emergency only on PROFITRON) - 8 binary electronic outputs for signals on PROFITRON, 5 outputs on ECOTRON All binary inputs and outputs are galvanically separated and potential-free. In addition, binary outputs are resistant to both short-circuits and overloads. Input Level Resistance 0 - 2,5 18 - 30 (typically 24) 4-7 max. 100 [Ω] Current (per input or output) Output 0-4 18 - 30 (typically 24) [mA]...

Open the catalog to page 14
Tecnical Data SIPOS 5 linear actuators 2SB5 - 15

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Wiring diagram ECOTRON-Direct connection Y070.058 Connection control and feedback signals Inputs Outputs analog binary binary max. 120mA Output 1) 1) Customer connection X3.1 1 2 3 4 5 6 7 8 9 10 11 12 13 X3.2 P24 int. / P24 G24 int. / G24 G24 int. P24 int. G24 int. / G24 G24 int. Output 5 Output 4 Output 3 Output 2 Output 1 Stop Open Close P24 int. Actuator internal + 0/4...20mA 0…600 - AO1 3) 14 15 16 17 18 19 20 21 22 23 24 25 26 Customer connection X1 P24 M N L1 X1 + 24V DC 2) N L PE P24 M L3 L2 L1 G24 ext. P24 ext. L1 N G24...

Open the catalog to page 15
Tecnical Data SIPOS 5 linear actuators 2SB5 - 16

Electric Linear Actuators 2SB5 SIPOS 5 Flash Technical Data Wiring diagram ECOTRON-Direct connection with relay board Y070.062 Connection control and feedback signals Inputs Outputs analog binary binary max. 120mA Output 1) 1) X3.1 1 3 4 5 6 7 8 9 10 11 12 13 X3.2 P24 int. / P24 G24 int. / G24 G24 int. P24 int. 14 15 16 17 18 19 20 21 22 23 24 25 26 Relay board Output 1 P24 M X1 N X1 N L PE P24 M L2 L1 G24 ext. P24 ext. L1 + 24V DC 2) X2 L1 N G24 ext. P24 ext. Actuator internal Connection power supply Customer connection G24 int. / G24 G24 int. Output 5 Output 4 Output 3 Output 2 Output 1...

Open the catalog to page 16