Catalog excerpts
Sinus Jevi Immersion Heaters The elements are especially designed for the heating of potable water. The elements can also be used for heating other media. The technical advisers of Sinus Jevi can provide advise of suitability. - 4 lengths 8 connection possibilities available with or without thermostat single or multiple phase connection thermostat available in 3 ranges Sinus-Jevi Electric Heating B.V.
Open the catalog to page 1Catalogue Immersion Heaters Immersion Heaters type I.S. The I.S. Series screw-in heating elements can be supplied in four types. Per type there are eight possibilities for electrical connection. The elements are especially designed for the heating of potable water. The elements can also be used for heating other media. The technical advisers of Sinus Jevi can provide advise of suitability. For correct operation, the heating element must be screwed direct into the reservoir. To prevent damage to the element, an application should be made to prevent the element in operation to be running...
Open the catalog to page 2Catalogue Immersion Heaters Overview I.S.-series screw-in heating elements Power Star configuration (3 X 400 V AC) Power Delta configuration (max. 3 X 400 V AC) Ohmic resistance each tube element Article number Immersion length Overview I.S.-series thermostats Temperature range Number of switching contacts Maximum switching power per contact Temperature sensor Article number The above thermostats are lid-mounted and feature a knob with scale. Type I.S. 2510 Immersion length 250 mm Type I.S. 3515 Immersion length 350 mm Data per wiring diagram, see page 4 Data per wiring diagram, see page 4...
Open the catalog to page 3Catalogue Immersion Heaters Wiring Diagram Connection IS-heating element The heating element can be connected in • Star connection Figure 1 / wiring diagram 1 A/B • Delta connection Figure 1 / wiring diagram 2 A/B In a single phase (phase-neutral or Figure 2 wiring diagram 3 A/B Figure 3 wiring diagram 4 A/B • 2 elements in series and 1 element Figure 3 / wiring diagram 5 A/B Figure 3 / wiring diagram 6 A/B Wiring diagram "A": IS-element without thermostat. Wiring diagram "B": IS-element with thermostat. *note: connection numbering identical for figures 2B to 6B SINUS JEViO
Open the catalog to page 4Catalogue Immersion Heaters The IS-elements will be supplied including the necessary accessories, including link plates, gasket and internal wiring. Any additional accessories can be ordered seperately. Accessories for IS-elements Article number Copper gasket with ceramic fill for RG 1½" plug (medium side) to 320°C Gasket D8012 (square) for junction box and cover and/or raised lid Standard screw-in element type ISI-01 The ISI-01 is ideal for heating water, in which case the element must be very compact. The immersion element consists of a brass cable gland, 1 double electric tubular element...
Open the catalog to page 5Catalogue Immersion Heaters Immersion Heaters type J.I.S. - Different lengths, power and materials - G 1½ " or G 2" brass plug - With or without junction box available
Open the catalog to page 6Catalogue Immersion Heaters Heating elements with a G 1½” or G 2” brass gland for heating water Screw-in elements of nickel plated copper are designed to heat up water in hot water tanks or open reservoirs. Copper is relatively soft material that expands with heat. This feature makes calcium on the heating element crumble. This contributes to a longer life of the element. This element can also be used as extra back up in heat pumps. Immersion length Watt density Immersion length Plug (Brass) Item number Immersion heaters with G 1½” or G 2” brass plug for aggressive liquids Immersion heaters...
Open the catalog to page 7Catalogue Immersion Heaters Heating elements with a G 2” brass plug for heating of oil Immersion heating elements, stainless steel (AISI 304) for heating of oil in e.g. oil pre-heaters and frost protection of oil containers. 3 x 400 Volt. Item number Watt density Immerison length Plug (Brass) Gaskets for immersion heaters Item number
Open the catalog to page 8Catalogue Immersion Heaters The junction boxes can also be supplied without holes for connection of heating elements, cable assembly, etc. Oval box in stainless steel for G 1½” (BSP) 10 mm cover, IP55, PG13.5 Oval box in stainless steel for G 2” (BSP) 10 mm cover, IP55, PG13.5 Square box for G 1½” (BSP) PG 16, 3-pole thermofuse, 110°C manual reset, IP44 Square box for G 2” (BSP) PG16, as 19905090, IP44 Square box for G 1½” (BSP) PG16, 3-pole thermostat 30-85°C Outside knob, IP22 Square box for G 2” (BSP) PG16, as 19905116, IP22 Square box for G 1½” (BSP), PG16 3-pole thermostat 30-85°C...
Open the catalog to page 9Sinus is one of the pioneers in the field of explosion proof heating equipment, today we are still operating at For the production of Ex-proof equipment a PQAN (Product by Sinus-Jevi Electric Heating B.V.
Open the catalog to page 10All Sinus-Jevi Electric Heating B.V. catalogs and technical brochures
-
IMH D-8530
6 Pages
-
IMH D-8800
4 Pages
-
IMH D-8680
8 Pages
-
IMH D-8640
8 Pages
-
Radiant Heaters
4 Pages
-
Heatray
3 Pages
-
Anti Condensation Heaters
14 Pages
-
Foot Heaters
3 Pages
-
Closed Tubular Heating Elements
10 Pages
-
Ceramic Heating Elements
6 Pages
-
Thermostats
5 Pages
-
Thermodyp Bath Heaters
4 Pages
-
Drum Heaters
3 Pages
-
Cartridge Heaters
34 Pages
-
Air Duct Heaters
6 Pages
-
Water Flow Heaters
6 Pages
-
Flame Proof Boilers
4 Pages
-
Finned Tube Air Heaters
7 Pages
-
IMMERSION HEATING ELEMENTS
12 Pages
Archived catalogs
-
WATER FLOW HEATERS
6 Pages
-
DRUM HEATERS
12 Pages
-
THERMODYP BATH HEATERS
4 Pages
-
CARTRIDGE HEATERS
36 Pages