IMH D-8640
8Pages

{{requestButtons}}

Catalog excerpts

IMH D-8640 - 1

Explosion-proof Immersion Heater Type D-8640 Sinus Jevi has developed explosionproof Ex 'de' heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to protect the environment against gas-explosions, caused by sparking by electrical connections of the heating elements and control devices. SINUS JEVin o> Gasses Solids Spaces Sinus-Jevi Electric Heating BV. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com

Open the catalog to page 1
IMH D-8640 - 2

Catalogue Immersion Heaters type D-8640 Gas and Dust flame-proof immersion heater type D-8640 For hazardous areas, Sinus Jevi has developed explosion-proof Ex 'de' heating equipment, designed and manufactured in accordance with EN-IEC 60079-0, EN-IEC 60079-1, EN 60079-7 and EN-IEC 60079-31 certified by the independent testing institute ISSeP. The certificates cover zone 1 and zone 2 for hazardous areas. Gas groups II A, II B and II C and temperature classes T6-T1. Dust group Ex tb zone 21. The flame-proof (d) enclosures have been designed for non save areas to protect the environment...

Open the catalog to page 2
IMH D-8640 - 3

Catalogue Immersion Heaters type D-8640 Description Suitable for heating of fluids both liquids and gases and also solids. The heater consists of a certified flameproof enclosure D-8640, containing: - certified electric heating elements (Ex e II) tubular, ceramic or cartridge heating elements. - one manually protective thermostat with manual reset or one thermocouple or pt100 as a safety device. Thermocouple and pt100 are only applicable in combination with an external temperature controller executed with a manual reset. - threaded holes for cable entries and/or plugs of a...

Open the catalog to page 3
IMH D-8640 - 4

Catalogue Immersion Heaters type D-8640 Flame-proof immersion heater type D-8640 for high working temperatures Flame-proof immersion heaters with retractable ceramic core elements. Single or multi core heaters. For horizontal installation (vertical installation available on request). The ceramic core elements can be withdrawn for inspection or replacement without having to drain the system. - Ambient temperature -30°C - +50°C (-50°C ... +50°C on request) - The maximum allowable voltage is 690 Volt. Marking ATEX Ex II 2 G D Ex d IIC T6-T1 Gb EN/IEC 60079-1 Ex tb IIIC T110°C Db EN/IEC...

Open the catalog to page 4
IMH D-8640 - 5

Catalogue Immersion Heaters type D-8640 Set point on safety thermostat inside the terminal enclosure: Temperature class T1 to T4: 90°C Gas and Dust flame-proof immersion heater type D-8640 VARIATION for relative low working temperatures Description The heater serie D-8640 variation is designed to heat a wide range of liquids, gases and solids. The heater consists of a certified flameproof enclosure Ex d II C T6 - T1 Gb, certified electric heating elements Ex e II and a manually reset protective safety device. Unheated length heating elements into the medium is 30 mm minimum. The surface...

Open the catalog to page 5
IMH D-8640 - 6

Catalogue Immersion Heaters type D-8640 Flame-proof immersion heater type D-8640 VARIATION for low working temperatures 191 Immersion length Safety thermostat in the medium - Threaded boss from 1½” G BSP up to 3” G BSP with tubular heating element. - Flange connection with tubular type heating element. Safety thermostat in the medium Safety thermostat in the medium - Flange connection with cartridge or retractable ceramic heating element. Immersion length Safety thermostat in the medium - Threaded boss from 1½” G BSP up to 3” G BSP with cartridge or retractable ceramic heating

Open the catalog to page 6
IMH D-8640 - 7

Catalogue Immersion Heaters type D-8640 Flame-proof immersion heater type D-8640 VARIATION for low working temperatures Note: safety thermostat in the enclosure Immersion length - Threaded boss from 1½” G BSP up to 3” G BSP with cartridge type heating element. Note: safety thermostat in the enclosure Immersion length - Threaded boss from 1½” G BSP up to 3” G BSP with tubular heating el

Open the catalog to page 7
IMH D-8640 - 8

Sinus is one of the pioneers in the field of explosion proof heating equipment, today we are still operating at the forefront. We manufacture according to ATEX as well as IECEx and EAC directives. For the production of Ex-proof equipment a PQAN (Product Quality Assurance Notification) is issued by TUV-Nord. Our ISO-9001 and ISO-14001 systems are also monitored by this organisation. Sinus-Jevi Electric Heating BV. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100

Open the catalog to page 8

All Sinus-Jevi Electric Heating B.V. catalogs and technical brochures

  1. IMH D-8530

    6 Pages

  2. IMH D-8800

    4 Pages

  3. IMH D-8680

    8 Pages

  4. Heatray

    3 Pages

  5. Foot Heaters

    3 Pages

  6. Thermostats

    5 Pages

  7. Drum Heaters

    3 Pages

Archived catalogs

  1. DRUM HEATERS

    12 Pages