Catalog excerpts
Used in combination with the SINGLE SC controller, the system allows fl ow metering and monitoring of up to 32 circuits or the fl ow rate and media return temperatures of up to 16 circuits. The SC controller has several interfaces for transferring data to the injection moulding machine’s control system for process monitoring or to other data acquisition systems/central computers. SINGLE SC controller Standard equipment • Graphics-enabled text display • Specifi cally assigned soft keys • Detailed alarm messages and real text parameters • Text messages can be received and called up in any language • Graphic presentation of measured values of all fl ow rates and temperatures • Trouble shooting tips can be called up in case of alarm • Alarm history • Digital interface via RS 232, RS 485, customer-specifi c protocols TTY, Profi bus DP, CAN Bus, Euromap 66, SPI, Modbus, Ethernet (optional) • Real-time clock with clock relay function (optional) • Parameters for twenty different moulds SINGLE SWV is a central system for distributing cooling and transfer media to multiple circuits in injection moulding machines. It is equipped with a precise fl ow meter according to the eddy current method. The standard system is designed for temperatures up to 100 °C and has a metering range of between 1 and 12 l/min. With its compact footprint, it is easily installed in injection moulding machines or mould spaces. Thanks to its modular design, SWV is infi nitely adaptable to between 4 and 32 temperature control circuits. The SINGLE SWV water distribution system is highly precise, wear-free, impervious to contamination and maintenance-free. SINGLE SWV Water distribution system Standard equipment General • C irculating medium water up to 100 °C • Modular design for between 4 and 32 temperature circuits • Compact footprint Hydraulics • High-precision, contamination-free fl ow metering according to the eddy current method • Wear-free operation • Maintenance-free construction Electrical equipment and control • SINGLE SC controller • Flow metering and monitoring of up to 32 circuits / fl ow rate and media return temperature metering and monitoring of up to 16 circuits • 2 m connection cable Options • Wider metering range from 2 to 40 l/min • Measuring point for median pressure • Measuring point for overall fl ow temperature • Solenoid valves for each circuit Operating in combination with the SC controller, the SWV water distribution system allows metering and monitoring of fl ow rates and media return temperatures SINGLE Water distribution system SWV Series SINGLE Temperiertechnik GmbH, Ostring 17-19, 73269 Hochdorf/Germany Tel.: +49 (0)7153/3009 - 0, Fax: +49 (0)7153/3009 - 50, www.single-temp.de
Open the catalog to page 1SINGLE SWV – Compact water distribution system for injection moulding machines All standard injection moulding machines are equipped with a water battery. The SINGLE SWV water distribution system with integrated fl ow meter is a maintenance-free alternative to conventional fl oat-type fl ow meters. While fl oat-type fl ow meters are inexpensive, they have a signifi cant drawback: incidence of light leads to algae growth, which contaminates the system. The algae layer obstructs the view through the inspection window and leads to a gradual reduction of the fl ow rate, deterioration of the...
Open the catalog to page 2The system is distinguished by • end-to-end metering • 100 % monitoring • documentation of fl ow rates and return temperatures The system’s outstanding features translate into obvious benefi ts, particularly for moulders catering to the medical engineering, optics and precision engineering segment as well as for manufacturers of high-precision industrial components that meet exacting requirements for clean and transparent production processes. For processors that are compelled to meet stringent documentation requirements, the SINGLE SWV water distribution system ideal for the reliable and...
Open the catalog to page 3The SINGLE SWV water distribution system for variotherm mould temperature control Used in combination with an upstream temperature control system and SINGLE EcoTemp intermittent mould temperature control, the SINGLE SWV water distribution system is a particularly economic variotherm mould temperature control option. In addition to these benefi ts, SWV is a cost-effi cient alternative to conventional pulsed cooling methods, as the solenoid valves used by these systems are prone to malfunction and require frequent servicing. Pulsed cooling systems often use impeller fl ow meters with moving...
Open the catalog to page 4All SINGLE Temperiertechnik catalogs and technical brochures
-
Water Mini
2 Pages
-
ATT
4 Pages
-
EcoTemp
2 Pages
-
Data sheet series 225C
1 Pages
-
Data sheet series D
2 Pages
-
Data sheet Flow Meter DFM
1 Pages
-
Data sheet Ecotemp
2 Pages
-
Data sheet SC
2 Pages
-
Data sheet series SKL
2 Pages
-
Data sheet series SKA
4 Pages
-
Data sheet series STL
2 Pages
-
Data sheet series M
2 Pages
-
Data sheet series H
2 Pages
-
Data sheet series N-G
2 Pages
-
Data sheet series K
2 Pages
-
Data sheet series TK
2 Pages