Reliant Series Fuel Tanks Day Tanks • Filtration Tanks • Specialty Tanks Insight Onsite ®
Open the catalog to page 1Reliant Series ® Day Tanks • Filtration Tanks • Specialty Tanks • Page 2 The Simplex Reliant Series is the latest design expression of a seventyyear history of innovation and reliability from the originator of the factory packaged day tank. Today, operating from a new and modern production facility, and with a staff of experienced, capable engineers, service technicians, and production team members, Simplex continues as the standard for design, product and service excellence. Overview • High reliability design systems fuel tanks for use as day tanks, main supply tanks, transfer tanks, return...
Open the catalog to page 2Insight Reliant Series Onsite Day Tanks • Filtration Tanks • Specialty Tanks • Page 3 Features Digital Controller • Double-wall secondary containment tank construction, UL listed • • • • • • Digital or analog controllers, UL listed • Local or remote pumping options, 2-50GPM, 0.33 – 5.0HP • Single or duplex, ll or return pumping congurations • Large option and accessory list • • Highly standardized and time proven design • Design-build project customization • Digital controllers network compatible • Fully compatible with complete Simplex Fuel Supply Systems product line, including pump sets, tank...
Open the catalog to page 3Reliant Series ® Day Tanks • Filtration Tanks • Specialty Tanks • Page 4 Analog Level Controller Multifunction liquid level controller: • Usable with any tank construction • Versatile mounting • Accessories to suit a multitude of tank level applications • Leak detection capability • UL 508A Listed The Simplex Analog Level Controller is a relay based design, oat switch activated, multifunction liquid level controller. SST applications include: • Single ll pump control • Duplex ll pump control, level switch activated • Duplex ll pump control, pressure switch activated • Single drain pump control...
Open the catalog to page 4Insight Onsite Reliant Series Day Tanks • Filtration Tanks • Specialty Tanks • Page 5 Model Numbers SRS-50 FR SRFT-50 FR SRX-50 FR SRS-50 PT SRFT-50 PT SRX-50 PT SRS-75 SRFT-75 SRX-75 UL2080 SRS-75 FR SRFT-75 FR SRX-75 FR SRS-75 PT SRFT-75 PT SRX-75 PT SRS-100 SRFT-100 SRX-100 UL2080 SRS-100 FR SRFT-100 FR SRX-100 FR SRS-100 PT SRFT-100 PT SRX-100 PT SRS-150 SRFT-150 SRX-150 UL2080 SRS-150 FR SRFT-150 FR SRX-150 FR SRS-150 PT SRFT-150 PT SRX-150 PT UL142 SRS-200 SRFT-200 SRX-200 UL2080 SRS-200 FR SRFT-200 FR SRX-200 FR UL2085 SRS-200 PT SRFT-200 PT SRX-200 PT UL142 SRS-275 SRFT-275 SRX-275 UL2080...
Open the catalog to page 5Reliant Series ® Day Tanks • Filtration Tanks • Specialty Tanks • Page 6 Standard UL142 Day Tank Dimensions 50 Gallon 75 Gallon Simplex, Inc. 5300 Rising Moon Road Springeld, IL 62711-6228 217-483-1600 Fax 217-483-1616 www.simplexdirect.com © 2011 Simplex, Inc. All Rights Reserved. Printed in the USA • 1102-08.00 Design subject to change without notice.
Open the catalog to page 6Insight Onsite Reliant Series Day Tanks • Filtration Tanks • Specialty Tanks • Page 7 Standard UL142 Day Tank Dimensions 100 Gallon 150 Gallon © 2011 Simplex, Inc. All Rights Reserved. Printed in the USA • 1102-08.00 Design subject to change without notice. 217-483-1600 Fax 217-483-1616 www.simplexdirect.com Simplex, Inc. 5300 Rising Moon Road Springeld, IL 62711-6228
Open the catalog to page 7Reliant Series ® Day Tanks • Filtration Tanks • Specialty Tanks • Page 8 Standard UL142 Day Tank Dimensions 200 Gallon 275, 325 & 400 Gallon Simplex, Inc. 5300 Rising Moon Road Springeld, IL 62711-6228 217-483-1600 Fax 217-483-1616 www.simplexdirect.com © 2011 Simplex, Inc. All Rights Reserved. Printed in the USA • 1102-08.00 Design subject to change without notice.
Open the catalog to page 8Insight Onsite Reliant Series Day Tanks • Filtration Tanks • Specialty Tanks • Page 9 Tank Fittings Typical Layout Typical Standard Fittings Port A B C D E F G H J K L M R S Description Size Engine Supply Drop Tube Siphon Drain Drop Tube Overow Port Engine Return Port Extra Pipe Flange Tank Vent Port Manual Fill Drop Tube Hand Pump Mounting Drop Tube Pump Connection To Tank Drop Tube Floatswitch MTG/Inspection Port Emergency Tank Vent Containment Basin Drain Containment Basin Leak Sensor Port Emergency Containment Vent 0.75" NPT, Male 0.75" NPT, Male 2.00" NPT, Female 1.00" NPT, Female 1.00"...
Open the catalog to page 9Reliant Series ® Day Tanks • Filtration Tanks • Specialty Tanks • Page 10 OPTIONS MECHANICAL 010 015 025 040 050 060 062 063 064 065 070 080 083 087 088 090 093 095 100 101 102 103 104 105 120 125 130 131 140 141 180 Auxiliary hand pump Auxiliary hand pump Locking manual fuel ll cap Wall-mounting brackets Pipe stand adapter Fuel strainer Duplex strainer Vent cap Emergency vent Drain hand valve Check valve/priming tee assembly Solenoid valve DC Solenoid Valve Manual fuel shut-off valve, bronze Manual fuel shut-off valve, rerated Foot valve Fusible link valve Pressure relief valve Pressure gauge...
Open the catalog to page 10Insight Onsite ENGINEER’S SPECIFICATION Sample specication for UL-142 doublewall secondary containment construction day tank with on-board supply duplex pumps drawing from a remote main source tank. The following denes a day tank with a duplex pump system designed for delivery of fuel from a source storage tank to a day tank, approximately 200feet horizontal and within 18-feet of vertical lift from the lowest point via a pump set installed on the day tank. At this site, consideration must be given to suction lift characteristics of pumps: this system will operate in the suction lift capability...
Open the catalog to page 11Reliant Series ® Day Tanks • Filtration Tanks • Specialty Tanks • Page 12 1.3.3.7 Day tank shall be factory leak tested at 3PSI. 1.3.3.8 The tank shall be steel doublewall secondary containment construction bearing the UL 142 label. The containment shall be equipped with a leak detector that shall activate the “leak” alarm described below. A drain with re rated ball valve is to be supplied. The containment shall be equipped with a separate e-vent as required by UL 142. 1.3.3.9 Supply re rated ball valves as follows: 1. Day tank drain 2. Secondary containment drain 1.4 Fuel delivery system: Provide...
Open the catalog to page 128 Pages