EC SERIES-1

ECO-TOP POWER electric motors SERIES (ELECTRONICALLY COMMUTED MOTORS)

 Open the catalog to page 1
EC SERIES-3

electric motors 03. SYNCHRONOUS MOTORS EC SERIES 05. DATA SHEET EC MOTORS 06. SYNCHRONOUS MOTORS ECI SERIES WITH INTEGRATED INVERTER 07. DATA SHEET ECI MOTORS

 Open the catalog to page 3
EC SERIES-4

electric motors 01. EC MOTORS EC (Electronically Commuted or Electronically Controlled), are motors with permanent magnets in the rotor and are controlled by an electronic control (inverter) which is used to control the voltage and frequency applied to the motor. The mechanical dimensions comply with the IEC standard, currently the sizes 71, 90, 100, 132 have been developed, the sizes 63.80.160 are in preparation, maximum speed 3600 rpm / min., Maximum power 22Kw (132), maximum torque 70Nm. The series developed are two, the EC series and the ECI series the two series have the same technology...

 Open the catalog to page 4
EC SERIES-5

POWER These electric motors work by the interaction of two magnetic fields, one magnetic field is created by the rotor and the other by the stator. EC motors use permanent magnets positioned on the rotor to create the rotor magnetic field and a series of coils controlled by a electronic control (inverter) to create the stator magnetic field. EC motors do not have brushes, therefore they do not have sparkle, the electronic stator control reduces losses and there is no dispersion of energy to induce the rotor field. EC motors are very efficient and maintain a high level of efficiency even at all...

 Open the catalog to page 5
EC SERIES-6

electric motors 02. TECHNOLOGY These motors have been studied mainly for the following sectors: -ventilation -pumps -compressor -applications where torque motors with permanent magnet are required These motors are designed for variable speed applications, such as, air conditioning, ventilation, when the speed must be varied to keep the flow / pressure constant, in all applications where the flow varies as the speed varies (compressors, pumps) these motors guarantee very high efficiency at different speeds, guaranteeing savings of at least 30% or more energy compared to traditional solutions....

 Open the catalog to page 6
EC SERIES-7

POWER 03. EC SERIES SYNCHRONOUS MOTORS The range of permanent magnet synchronous motors of the EC series, in production, is indicated in the table below: EC series permanent magnet synchronous motors must be powered by a commercial external driver (inverter), below are the configuration parameters of the inverter in order to power Techtop EC series permanent magnet synchronous motors:

 Open the catalog to page 7
EC SERIES-8

electric motors 03. SYNCHRONOUS MOTORS EC SERIES Parameters Stator resistans Rs, Lineto-Starpoint [Ω] Stator inductance Ld, Line-to-Starpoint [mH] Stator inductance Lq, Line-to-Sarpoint [mH] Pole pairs BEMF constant Ke, Lineto-Line [Vms/1000rpm] Stator resistans Rs, Lineto-Starpoint [Ω] Stator inductance Ld, Line-to-Starpoint [mH] Stator inductance Lq, Line-to-Sarpoint [mH] Pole pairs BEMF constant Ke, Lineto-Line [Vms/1000rpm] EC motor name plate sample:

 Open the catalog to page 8
EC SERIES-10

electric motors 04. CONNECTIONS I motori EC possono funzionare a Torque costante da 0 a 3600 giri, con Power crescente, la velocità è legata alla Frequency di alimentazione del motore EC da parte dell’inverter, la relazione tra Frequency di alimentazione e velocità del motore EC è la seguente: rpm/min.= Frequency(Hz)xK Frame CONNECTION FROM INVERTER AND EC MOTOR: The inverter must be powered with a voltage in the range between 360V and 460V with a frequency of 50Hz or 60Hz and the motor must be powered by the inverter with the voltage indicated in the data tables and with the frequency necessary...

 Open the catalog to page 10
EC SERIES-11

POWER Changing the motor connection from Star (Y) to Delta (Δ) the inverter parameters must be changed, in general the maximum speed, frequency, power, current, resistance, inductance must be changed, the back EMF value, the variation of the parameters must follow what is indicated in the following table; Parametri power output EC motor parameters for the Driver (VSD): example for T90EC03 motor: Items Rated current: The operating range in power-torque indicated in the tables and data sheets of the EC motors refer to the S1 service and the cooling system of the IC410 motor (motor without cooling,...

 Open the catalog to page 11
EC SERIES-12

electric motors 05. DATA SHEET MOTORI EC EC Motor Data Sheet Typical information: Motor model: Motor type: Rated torque: Max speed: Maximum torque: Rotor position sensor: 71EC03X36 Permanent magnet synchronous motor 3.2 N.m *No cooling condition 1800 Y rpm 3600 Δ rpm 4 N.m No Performance data: Motor connection: Maximum speed:

 Open the catalog to page 12
EC SERIES-13

POWER Performance data: Motor connection: Maximum speed:

 Open the catalog to page 13
EC SERIES-14

electric motors Motor parameters for VSD: Items VSD input voltage: Phase numbers input: Pole numbers: Max speed: Max frequency: VSD output voltage: Rated current: Max output power: Resistance: Ld: Lq: BEMF V per 1000 rpm: Note V Input to inverter motor rpm Hz V A w Ohm mH mH Rms Line - Neutrial Motor running power range: Duty cycle: S1 Cooling condition: IC410, IC411, IC 418 The motor output power can be improved based on better cooling. *The motor running power range is reference to choose the correct load. The ambient temperature is based on 35 deg C. *S2 or other duty cycle can reach higher...

 Open the catalog to page 14
EC SERIES-15

Axial fan load cooling

 Open the catalog to page 15
EC SERIES-16

electric motors EC Motor Data Sheet Typical information: Motor model: Rated torque: Max speed: Maximum torque: Rotor position sensor: Performance data: Motor connection: Maximum speed:

 Open the catalog to page 16
EC SERIES-17

POWER Performance data: Motor connection: ∆ Maximum speed: 3600 rpm

 Open the catalog to page 17
EC SERIES-18

electric motors Items VSD input voltage: Max speed: Max frequency: VSD output voltage: Rated current: Resistance: Ld: Lq: Back EMF value: Unit Note V rpm Hz V A Ohm Phase mH Phase mH Phase Vrms per 1000 rpm Motor running power range: Duty cycle: S1 Cooling condition: IC410, IC411, Cooling by axial fan load *The motor running power range is reference to choose the correct load. The ambient temperature is based on 35 deg C. *S2 or other duty cycle can reach higher power based on the duty cycle value.

 Open the catalog to page 18
EC SERIES-19

Axial fan load cooling Motor dimension and mounting method: *The feet can be removed *The mounting method can be B5 and B34

 Open the catalog to page 19