STI-94
1 /3Pages

STI-94

STI-94
1 /3Pages

Catalog excerpts

STI-94-1

Ratemeters / Tachometers STI-94 pulse rate / period meter rotational / linear speed control revolution / movement period control 0, 2 or 4 REL / OC outputs analogue output: active or passive, power supply output: 24V DC RS-485 / Modbus RTU "over" signalling when the measuring range is exceeded free configuration software S-Config The STI-94 tachometers are designed to control rotational or linear speed of moving objects. The device is also able to measure frequency. As an additional advantage the device can convert the rotational / linear speed into inverse values, and to display the single revolution period or process duration. The REL / OC control outputs can be programmed depending on the instantaneous value of rotational speed. Additionally the counter may be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The counter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. TECHNICAL DATA 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W LED, 6 x 13 mm high, red, brightness adjustable in 8 steps pulse, fully isolated, with debouncing filter and pulse width control, max. input frequency 50.0 kHz Input levels low level: 0 V ÷ 1 V; high level: 10 V ÷ 30 V (about 12 mA @ 24V) Displayed values range Rotational speed precision selected in the range 0 ÷ 0.00000 of unit Rotational speed unit revolutions per second (rps), per minute (rpm), per hour (rph) Pulse waiting time settable from 0.1 to 39.9 seconds ± 0.02% ± one digit (full temperature range) Binary outputs Analogue output (available with 2 x REL or OC, see ordering) active current: operating range 0/4-20 mA (max. 0-24 mA), load resistance 700 Ω max., resolution 13 bit passive current: isolated, operating range 4-20 mA (max. 2,8-24 mA), load resistance 600 Ω@24VDC, resolution 13 bit active voltage: operating range 0/1-5V, 0/2-10V (max. 0-11V), load resistance min. 2000 Ω, resolution 13 bit Power supply output Communication interface RS-485, 8N1 and 8N2, 1200 bit/s ÷ 115200 bit/s, Modbus RTU (not galvanically isolated) Operating temperature Storage temperature -10°C ÷ +70°C (standard), -20°C ÷ +70°C (depending on option) Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips) panel mounting; material: NORYL - GFN2S E1 case (WxHxD): 96 x 48 x 100 mm panel cut-out dimensions: 90,5 x 43 mm installation depth: min. 102 mm board thickness: standard 7 mm or other depending on used board thickness brackets (see Accessories) Power supply Power consumption SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07

 Open the catalog to page 1
STI-94-2

Ratemeters / Tachometers DIMENSIONS 5 Side view Case dimensions Panel cut-out dimensions ACTIVE current output version with 2 x REL and 1 x AO 0/4-20 mA, active ACTIVE voltage output version with 2 x REL and 1 x AO 0/1-5V, 0/2-10V, active PASSIVE isolated current output version with 2 x OC and 1 x AO 4-20 mA, passive options: 00 : no options 01 : IP 65 frame 08 : operating temp. -20°C ÷ +50°C 0P : IP 65 frame + operating temp. -20°C ÷ +50°C SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl power supply: type of outputs: 3 : 24V AC/DC 0 :...

 Open the catalog to page 2
STI-94-3

Counters accessories SMP-99/94 to mount 96 x 48 mm size unit in place of 96 x 96 mm cut-out MOUNTING PLATES SMP-147/94 to mount 96 x 48 mm size unit in place of 144 x 72 mm cut-out BOARD THICKNESS BRACKETS / ADAPTORS SPH-07 1 ÷ 7 mm board thickness brackets (2 pcs) standard included with device SPH-05 1 ÷ 5 mm board thickness brackets (2 pcs) SPH-45 1 ÷ 45 mm board thickness brackets (2 pcs) SRH-94 brackets for mounting devices on DIN 35/7.5 or 15 rail (2 pcs) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows user to change the configuration...

 Open the catalog to page 3

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. SLN-44D

    2  Pages

  2. STH-42

    2  Pages

  3. SPP-638

    3  Pages

  4. SLC_30_46_47

    2  Pages

  5. SLN-44

    2  Pages

  6. SLE-42

    2  Pages

  7. SWZ-W610

    3  Pages

  8. SPP-N118

    3  Pages

  9. SPP-94

    3  Pages

  10. SPI-638

    3  Pages

  11. SPI-N118

    3  Pages

  12. SPI-94

    3  Pages

  13. STI-638

    3  Pages

  14. STI-N118

    3  Pages

  15. STI-73

    3  Pages

  16. SLN-94

    3  Pages

  17. SLK-94T

    3  Pages

  18. SLIK-638

    3  Pages

  19. SLB-94

    3  Pages

  20. SLIK-94

    3  Pages

  21. SLIK-73

    3  Pages

  22. SLE-73

    3  Pages

  23. SLC-457

    3  Pages

  24. SLC-94

    3  Pages

  25. SCK-11

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.