SPP-N118
3Pages

{{requestButtons}}

Catalog excerpts

SPP-N118 - 1

Flow meters flow meter, batcher, totalizer in wall mounted IP 67 case 1 input 0/4-20 mA + 1 programmable function input 0 or 2 REL / OC outputs analogue output: active or passive, power supply output: 24V DC RS-485 / Modbus RTU display of instantaneous and the total flow values batching and counting of doses free configuration software S-Config The SPP-N118 flow counters are encased in a tight, wall-mounted housing (IP 67) and designed to work together with flow transducers equipped with analogue input. The purpose of flow counters is to measure the instantaneous flow value and to record the total flow of media like liquids, gases or loose materials. A wide range of total flow indication (up to 16 digits) allows controlling the flow value for a long operation time. Thanks to the built-in batcher function the SPP-N118 counters can be used in many industries like: food, pharmaceutical or paint and varnish industry. The REL / OC control outputs can be programmed depending on the instantaneous flow value, batcher or total flow value. Additionally the counter may be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The counter may be configured with no need to open the case, by using the remote controller or with free S-Config software via the RS-485 communication port. TECHNICAL DATA 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 5 VA; for 19V ÷ 50V DC power supply: max. 5 W LED, 6 x 13 mm high, red, brightness adjustable in 8 steps Displayed values range current: 0 ÷ 20 mA or 4 ÷ 20 mA, overload-protected, sinking current limited to ca. 40 mA, input resist.: < 65 Ω (typ. 50 Ω) programmable: binary 24V DC, not separated Input levels low level: 0 V ÷ 1 V, high level: 10 V ÷ 30 V (about 12 mA @ 24V) Counter capacity total flow: over 4 x 109 m3 with max. resistance 0,001 l (max. 16 significant digits); batcher: up to 65536 m3 Readout precision instantaneous flow values: selected in the 0 ÷ 0.000 of unit; total flow and batcher: selected in the 0 ÷ 0.000 of unit instantaneous flow values: l or m3 per second, minute or hour; total flow and batcher: l or m3 Outputs (option) Analogue output (available with 1 x REL or OC, see ordering) active current: operating range 0/4-20 mA (max. 0-24 mA), load resistance 700 Ω max., resolution 13 bit passive current: isolated, operating range 4-20 mA (max. 2,8-24 mA), load resistance 600 Ω@24VDC, resolution 13 bit active voltage: operating range 0/1-5V, 0/2-10V (max. 0-11V), load resistance min. 2000 Ω, resolution 13 bit Power supply output Communication interface RS-485, 8N1 and 8N2, 1200 bit/s ÷ 115200 bit/s, Modbus RTU (not galvanically isolated) Data memory non-volatile memory, EEPROM type Operating temperature Storage temperature -10°C ÷ +70°C (standard), -20°C ÷ +70°C (depending on option) Protection class wall mounting; material: ABS + polycarbonate (standard); 100% polycarbonate (on request) Dimensions (WxHxD) without glands: 110 x 80 x 67 mm; with glands: 110 x 105 x 67 mm SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl

Open the catalog to page 1
SPP-N118 - 2

Flow meters DIMENSIONS Case dimensions Side view Distances between mounting holes programmable input ACTIVE current output version with 1 x REL and 1 x AO 0/4-20 mA, active ACTIVE voltage output programmable input PASSIVE 85-260V isolated AC/DC current 5VA output version with 1 x REL and 1 x AO 0/1-5V, 0/2-10V, active programmable input programmable input version with 1 x OC and 1 x AO 4-20 mA, passive ORDERING SPP-N118-11XX-1-X-XX1 number of outputs: 0 2 options: 00 : no options 08 : operating temp. -20°C ÷ +50°C SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax...

Open the catalog to page 2
SPP-N118 - 3

Counters accessories REMOTE CONTROLLER SIR-15 InfraRed remote controllers may be used as external programming keyboard for all SIMEX devices equipped with IR receivers and remote programming functions. Pressing of any local IR controller key, causes transmission of it's code to the device. Functions of particular keys depend on devices features. Power supply voltage: Operation range: 6V DC - 4 alkaline batteries type LR44 from 0,5 to 5 m (depend on programmed device features) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows...

Open the catalog to page 3

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. STH-42

    2 Pages

  2. SPP-638

    3 Pages

  3. SLC_30_46_47

    2 Pages

  4. SLN-44

    2 Pages

  5. SLE-42

    2 Pages

  6. SWZ-W610

    3 Pages

  7. SPP-94

    3 Pages

  8. SPI-638

    3 Pages

  9. SPI-N118

    3 Pages

  10. SPI-94

    3 Pages

  11. STI-638

    3 Pages

  12. STI-N118

    3 Pages

  13. STI-94

    3 Pages

  14. STI-73

    3 Pages

  15. SLN-94

    3 Pages

  16. SLK-94T

    3 Pages

  17. SLIK-638

    3 Pages

  18. SLB-94

    3 Pages

  19. SLIK-94

    3 Pages

  20. SLIK-73

    3 Pages

  21. SLE-73

    3 Pages

  22. SLC-457

    3 Pages

  23. SLC-94

    3 Pages

  24. MultiCon

    19 Pages

  25. SCK-11

    1 Pages

Archived catalogs

  1. SWS-99

    1 Pages