SPI-94
3Pages

{{requestButtons}}

Catalog excerpts

SPI-94 - 1

Flow meters SPI-94 flow meter, batcher, totalizer 1 pulse counting input + 3 control inputs 0, 2 or 4 REL / OC outputs analogue output: active or passive, power supply output: 24V DC RS-485 / Modbus RTU display of instantaneous and the total flow values batching and counting of doses free configuration software S-Config The SPI-94 flow counters are designed to work together with flow transducers equipped with contact or electronic inputs. The purpose of flow counters is to measure the instantaneous flow value and to record the total flow of media like liquids, gases or loose materials. A wide range of total flow indication (up to 16 digits) allows controlling the flow value for a long operation time. Thanks to the built-in batcher function the SPI-94 counters can be used in many industries like: food, pharmaceutical or paint and varnish industry. The REL / OC control outputs can be programmed depending on the instantaneous flow value, batcher or total flow value. Additionally the counter may be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The counter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. TECHNICAL DATA 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 6,5 VA; for 19V ÷ 50V DC power supply: max. 6,5 W Displayed values range pulse, fully isolated: - counting input with debouncing filter and pulse width control, max. input frequency 10.0 kHz - zeroing of batcher counter, active edge or level - zeroing of total counter, active edge or level - counting blockade, active edge or level Input levels low level: 0 V ÷ 1 V; high level: 10 V ÷ 30 V (about 12 mA @ 24V) frequency: ± 0.02% (full temperature range); flow: equivalent to used flow sensor precision Counter capacity total flow: over 4 x 109 m3 (max. 16 significant digits); batcher: up to 65536 m3 Readout precision instantaneous flow values: selected in the 0 ÷ 0.00000 of unit; total flow and batcher: selected in the 0 ÷ 0.000 of unit instantaneous flow values: l or m3 per second, minute or hour; total flow and batcher: l or m3 Pulse waiting time settable from 0,1 to 39,9 seconds Binary outputs Analogue output (available with 2 x REL or OC, see ordering) active current: operating range 0/4-20 mA (max. 0-24 mA), load resistance 700 Ω max., resolution 13 bit passive current: isolated, operating range 4-20 mA (max. 2,8-24 mA), load resistance 600 Ω@24VDC, resolution 13 bit active voltage: operating range 0/1-5V, 0/2-10V (max. 0-11V), load resistance min. 2000 Ω, resolution 13 bit Power supply output Communication interface RS-485, 8N1 and 8N2, 1200 bit/s ÷ 115200 bit/s, Modbus RTU (not galvanically isolated) Operating temperature Storage temperature -10°C ÷ +70°C (standard), -20°C ÷ +70°C (depending on option) Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips) panel mounting; material: NORYL - GFN2S E1 case (WxHxD): 96 x 48 x 100 mm panel cut-out: 90,5 x 43 mm installation depth: min. 102 mm board thickness: standard 7 mm or other depending on used board thickness brackets (see Accessories) SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl Power supply

Open the catalog to page 1
SPI-94 - 2

Flow meters DIMENSIONS 5 Side view Case dimensions Panel cut-out dimensions ACTIVE current output A: pulse input B: counting inhibition C: balance counter clearing D: batching counter clearing com: common input version with 2 x REL and 1 x AO 0/4-20 mA, active ACTIVE voltage output A: pulse input B: counting inhibition C: balance counter clearing D: batching counter clearing com: common input PASSIVE isolated current output A: pulse input B: counting inhibition C: balance counter clearing D: batching counter clearing com: common input version with 2 x OC and 1 x AO 4-20 mA, passive version...

Open the catalog to page 2
SPI-94 - 3

Counters accessories SMP-99/94 to mount 96 x 48 mm size unit in place of 96 x 96 mm cut-out MOUNTING PLATES SMP-147/94 to mount 96 x 48 mm size unit in place of 144 x 72 mm cut-out BOARD THICKNESS BRACKETS / ADAPTORS SPH-07 1 ÷ 7 mm board thickness brackets (2 pcs) standard included with device SPH-05 1 ÷ 5 mm board thickness brackets (2 pcs) SPH-45 1 ÷ 45 mm board thickness brackets (2 pcs) SRH-94 brackets for mounting devices on DIN 35/7.5 or 15 rail (2 pcs) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows user to change the...

Open the catalog to page 3

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. STH-42

    2 Pages

  2. SPP-638

    3 Pages

  3. SLC_30_46_47

    2 Pages

  4. SLN-44

    2 Pages

  5. SLE-42

    2 Pages

  6. SWZ-W610

    3 Pages

  7. SPP-N118

    3 Pages

  8. SPP-94

    3 Pages

  9. SPI-638

    3 Pages

  10. SPI-N118

    3 Pages

  11. STI-638

    3 Pages

  12. STI-N118

    3 Pages

  13. STI-94

    3 Pages

  14. STI-73

    3 Pages

  15. SLN-94

    3 Pages

  16. SLK-94T

    3 Pages

  17. SLIK-638

    3 Pages

  18. SLB-94

    3 Pages

  19. SLIK-94

    3 Pages

  20. SLIK-73

    3 Pages

  21. SLE-73

    3 Pages

  22. SLC-457

    3 Pages

  23. SLC-94

    3 Pages

  24. MultiCon

    19 Pages

  25. SCK-11

    1 Pages

Archived catalogs

  1. SWS-99

    1 Pages