SLE-73

SLE-73

SLE-73

Product catalog summary
Power Supply and Consumption: The device supports a wide range of power inputs: 19V to 50V DC, 16V to 35V AC, or 85V to 260V AC/DC, all isolated. Maximum power consumption is 4.5 VA for AC and 4.5 W for DC.
Display: Features a red LED display with adjustable brightness in 8 steps, capable of showing values from -99999 to 999999 with decimal point and overflow indication.
Inputs: Includes pulse inputs that are galvanically isolated, with a common (COM) input. It supports counting down-up and up-down (PNP) with programmable functions. Input levels are defined as low (0V to 1V) and high (10V to 30V), with a frequency capacity of 3 kHz for electronic sensors and 90 Hz for contact sensors.
Output and Communication: Provides a 24V DC power supply output, stabilized, with a maximum of 100 mA. Communication is facilitated through an RS-485 interface supporting Modbus RTU protocol.
Memory and Temperature: Equipped with non-volatile EEPROM memory. Operating temperature ranges from 0°C to +50°C, with an optional range of -20°C to +50°C. Storage temperature ranges from -10°C to +70°C.
Protection and Dimensions: The device has an IP 65 protection class for the front and IP 20 for the case and connection clips. It is designed for panel mounting with dimensions of 72 x 36 x 97 mm.
Functionality: The SLE-73 meters are designed for progressive impulse counting, featuring two entry ports for counting and programmable functions. It includes a built-in divisor and adjustable decimal point for converting impulses into required units. Configuration can be done via a local keyboard or S-Config software through the RS-485 port.
Software and Accessories: SimCorder Soft is available for data acquisition and visualization, while S-Config 2 allows for device configuration in Modbus RTU networks. The SRS-U4 module connects USB hosts to RS-485 devices, ensuring galvanic isolation.
See more

Catalog excerpts

SLE-73-1

Electronic counters SLE-73 economical pulse counter 1 pulse counting input 1 programmable function input power supply output 24V DC prescaler and digital filter RS-485 / Modbus RTU free configuration software S-Config The SLE-73 meters have been designed exclusively for applications where a progressive counting of impulses is required. They feature two entry ports: counting and with a programmable function that can be used for resetting the meter to zero or stopping / changing its direction of travel (as required). The built-in entry port divisor with programmable value from 1 to 9999, along with an adjustable decimal point, permits a simple transfer of incoming impulses into the units required. The counter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. TECHNICAL DATA Power supply Power consumption 19V ÷ 50V DC; 16V ÷ 35V AC or 85 ÷ 260V AC/DC, all separated for 85 ÷ 260V AC/DC and 16V ÷ 35V AC power supply: max. 4,5 VA; for 19V ÷ 50V DC power supply: max. 4,5 W LED, 6 x 9 mm high, red, brightness adjustable in 8 steps Displayed values range -99999 ÷ 999999 + decimal point, with signalling of overfilling pulse, galvanically isolated: - counting down-up and up-down (PNP) - programmable function (PNP) - common (COM) Input levels low level: 0 V ÷ 1 V; high level: 10 V ÷ 30 V (12 mA @ 24V) Input frequency electronic sensor: 3 kHz contact sensor: max. 90 Hz (adjustable filter) Power supply output Communication interface RS-485, 8N1 and 8N2, 1200 bit/s ÷ 115200 bit/s, Modbus RTU (not galvanically isolated) non-volatile memory, EEPROM type Operating temperature Storage temperature -10°C ÷ +70°C (standard), -20°C ÷ +70°C (depending on option) Protection class IP 65 (front), available additional frame IP 65 for panel cut-out sealing; IP 20 (case and connection clips) panel mounting; material: NORYL - GFN2S E1 case (WxHxD): 72 x 36 x 97 mm panel cut-out dimensions: 66,5 x 32,5 mm installation depth: min. 102 mm board thickness: standard 7 mm or other depending on used board thickness brackets (see Accessories) Data memory SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, ww

 Open the catalog to page 1
SLE-73-2

Electronic counters DIMENSIONS 5 Side view Case dimensions Panel cut-out dimensions EXAMPLARY PIN ASSIGNMENT +24V RS-485 /100mA + Uo - GND DATA DATA + - common input + programmable input (PNP) + counting input (PNP) ORDERING SLE-73-1400-1-X-XX1 options: 00 : no options 01 : IP 65 frame 08 : operating temp. -20°C ÷ +50°C 0P : IP 65 frame + operating temp. -20°C ÷ +50°C SIMEX Ltd., Wielopole 11, 80-556 Gdańsk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl

 Open the catalog to page 2
SLE-73-3

Counters accessories MOUNTING PLATES SMP-147/73 maskownica 144 x 72 mm do montażu urządzeń w obudowie 72 x 36 mm BOARD THICKNESS BRACKETS / ADAPTORS SPH-07 1 ÷ 7 mm board thickness brackets (2 pcs) standard included with device SPH-05 1 ÷ 5 mm board thickness brackets (2 pcs) SPH-45 1 ÷ 45 mm board thickness brackets (2 pcs) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows user to change the configuration of most of them. For each detected device a list of its registers, which the user can modify, is displayed and also additional...

 Open the catalog to page 3

All SIMEX Sp. z o.o. catalogs and technical brochures

  1. SLN-44D

    2  Pages

  2. STH-42

    2  Pages

  3. SPP-638

    3  Pages

  4. SLC_30_46_47

    2  Pages

  5. SLN-44

    2  Pages

  6. SLE-42

    2  Pages

  7. SWZ-W610

    3  Pages

  8. SPP-N118

    3  Pages

  9. SPP-94

    3  Pages

  10. SPI-638

    3  Pages

  11. SPI-N118

    3  Pages

  12. SPI-94

    3  Pages

  13. STI-638

    3  Pages

  14. STI-N118

    3  Pages

  15. STI-94

    3  Pages

  16. STI-73

    3  Pages

  17. SLN-94

    3  Pages

  18. SLK-94T

    3  Pages

  19. SLIK-638

    3  Pages

  20. SLB-94

    3  Pages

  21. SLIK-94

    3  Pages

  22. SLIK-73

    3  Pages

  23. SLC-457

    3  Pages

  24. SLC-94

    3  Pages

  25. SCK-11

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.