Process meters Qsimex n SRL-49 process meter with bargraph inputs: 0/4-20 mA, 0/1-5V, 0/2-10V 0, 2 or 4 REL / OC outputs analogue output: active or passive, power supply output: 24V DC RS-485 / Modbus RTU signal peak value detection free configuration software S-Config The SRL-49 meter is designed for measuring of typical current or voltage signals. The readout is presented simultaneously on a four-decade LED display and a 20-point, two-colour bargraph covering the full measuring range. Thanks to wide range of characteristic curves (linear, square root, quadratic, user-defined and volume characteristic for cylindrical tanks) the meters may be used in various process control systems. The 24V DC / 100 mA output is designed to supply measuring transducers, and the RS-485 port enables data transmission in production process monitoring systems. The REL / OC control outputs can adjust the level of measured signal and are controlled according to one or two threshold values. Moreover, the meter can be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output. The meter can be configured with the local keyboard or free S-Config software via the RS-485 communication port. SIMEX Ltd., Wielopole 11, 80-556 Gdansk, Poland, tel. (+48) 58 762-07-77, fax 58 762-07-70, www.simex.pl
Open the catalog to page 1Process meters Side view Panel cut-out dimensions ACTIVE current output version with 2 x REL and 1 x AO 0/1-5V, 0/2-10V, active ORDERING number of outputs: 0 2 3 4 2 : OC (for 2 and 4 outputs) 3 : 2 x REL + 1 x AO (0/4-20 mA, active, non-isolated) 4 : 2 x OC + 1 x AO (0/4-20 mA, active, non-isolated) 9 : 2 x REL + 1 x AO (4-20 mA, passive, isolated) A : 2 x OC + 1 x AO (4-20 mA, passive, isolated) B : 2 x REL + 1 x AO (0/1-5V, 0/2-10V, active, non-isolated) C : 2 x OC + 1 x AO (0/1-5V, 0/2-10V, active, non-isolated) options: 00 : no options 01 : IP 65 frame 08 : operating temp. -20°C - +50°C 0P...
Open the catalog to page 2Meters accessories MOUNTING PLATES SMP-147/94 to mount 48 x 96 mm size unit in place of 144 x 72 mm cut-out SMP-99/94 to mount 48 x 96 mm size unit in place of 96 x 96 mm cut-out BOARD THICKNESS BRACKETS / ADAPTORS SPH-07 1 ÷ 7 mm board thickness brackets (2 pcs) standard included with device SPH-05 1 ÷ 5 mm board thickness brackets (2 pcs) SPH-45 1 ÷ 45 mm board thickness brackets (2 pcs) SRH-99 brackets for mounting devices on DIN 35/7.5 or 15 rail (2 pcs) SOFTWARE S-Config 2 is used for the simultaneous detection of devices in multiple Modbus RTU networks and allows user to change the configuration...
Open the catalog to page 32 Pages
96 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
19 Pages
1 Page
7 Pages
4 Pages
3 Pages
1 Page